Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-20 Cont ID  
Sent By lsmith Date 2002-06-20 Time 09:31 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-10 Cont ID  
Sent By btrobaug Date 2002-05-15 Time 15:49 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-06-10 00:00:00******************FAILED***************
  
 1. MUST REFERENCE FBC2001 FOR SAFETY
 FEATURES FROM HOUSE TO POOL.
 2. POOL MUST BE BUILT ACCORDING TO
 FBC2001,
 3. DRAWINGS MUST SHOW DETAIL FOR ANCHORI
 NG OF EQUIPMENT TO CEMENT SLAB.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-18 Cont ID  
Sent By btrobaug Date 2002-06-18 Time 11:22 Rev Time 0.00
Received By btrobaug Date 2002-06-18 Time 11:13 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-15 Cont ID  
Sent By kstevens Date 2002-05-15 Time 15:22 Rev Time 0.00
Received By btrobaug Date 2002-05-15 Time 15:42 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-18 Cont ID  
Sent By btrobaug Date 2002-06-18 Time 11:22 Rev Time 0.00
Received By kstevens Date 2002-06-18 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-05-15 Cont ID  
Sent By kstevens Date 2002-05-15 Time 15:15 Rev Time 0.00
Received By kstevens Date 2002-05-15 Time 15:15 Sent To E
Notes
2002-05-15 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92. AND NSPI-5 (ADD TO NOTES
 3) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 4) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 5) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 6) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 7) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 8) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 9) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 10) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-06 Cont ID  
Sent By sgraham Date 2002-05-06 Time 15:49 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***