Plan Review Details - Permit 02050157
Plan Review Stops For Permit 02050157
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-09 Cont ID  
Sent By btrobaug Date 2002-05-09 Time 17:19 Rev Time 0.00
Received By btrobaug Date 2002-05-09 Time 17:14 Sent To  
Notes
2002-05-09 00:00:00~~~~~~~~~~~~~~~~~PROVISO!~~~~~~~~~~~~~~~
  
 PLEASE COMPLY WITH THE FOLLOWING:
  
 1} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 2} SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 IN THE VICINITY OF BEDROOMS AND CLOSE
 PROXIMITY OF STIRWAYS. 2-5.2.1.3
 3'FT FROM BATHS/KITCHENS.2-5.2.1.6
  
 3} PLEASE NOTE, EITHERMISSING
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
  
 4} PLEASE INSTALL REQ`D ARC
 FAULT PROTECTED CIRCUITS AND LIST SAME
 ON PANEL SCHEDULE PER 210-10.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL;
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-05-07 Cont ID  
Sent By btrobaug Date 2002-05-07 Time 06:35 Rev Time 0.00
Received By btrobaug Date 2002-05-07 Time 06:23 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved