Plan Review Details - Permit 02050109
Plan Review Stops For Permit 02050109
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-08-07 Cont ID  
Sent By jwitmer Date 2002-08-07 Time 11:05 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-08-07 Cont ID  
Sent By jwitmer Date 2002-08-07 Time 10:35 Rev Time 1.00
Received By jwitmer Date 2002-08-07 Time 10:35 Sent To  
Notes
2002-08-07 00:00:00DISSCUSSED PERMIT & FIELD CONDITIONS
 WITH B.O. N. MELICK AS TO WHAT EXTENT
 EXIST BUILD SHALL BE MADE ACCESSIBLE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-07-16 Cont ID  
Sent By jwitmer Date 2002-07-16 Time 08:44 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-07-16 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 02061710
 ADD: 2950 SARATOGA RD
 CONT: COLUMBIA BLDG & DESIGN
 TEL: (561)624-8009
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENETRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY.
  
 2)11-4.1.2 VERTICAL ACCESSIBILITY,
 NOTHING IN THIS CODE SHALL BE CONSTRUED
 TO RELIEVE THE OWNER OF ANY BUILDING,
 SSTRUCTURE OR FACILITY FROM THE DUTY TO
 PROVIDE VERTICAL ACCESSIBILITY TO ALL
 LEVELS ABOVE OR BELOW THE OCCUPIAABLE
 GRADE LEVEL.
  
 3)A PATH OF TRAVEL TO ALL ELEMENTS OF
 THE GARD HOUSE, RAMP, ENTRY,AND PARKING
 SHALL COMPLY WITH THE FLORIDA ACCESSIBIL
 ITY CODE, INCLUDING THE NEW ADDITION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-05-14 Cont ID  
Sent By jwitmer Date 2002-05-14 Time 11:15 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-14 00:00:00BUILDING PLAN REVIEW
 PRMIT # 02050109
 2950 SARATOGA RD
 CONT: COLUMBIA BUILDING DESIGN
 TEL: 624-8009
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS SUBMITTED AFTER FEB. 28TH/ 2002
 SHALL BE DESIGNED TO THE 2001 FL BLD
 CODE.
  
 2)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 3) 1804.1.3 THE BOTTOM OF FOUNDATIONS
 SHALL EXTEND NO LESS THAN 12" BELOW
 FINISH GRADE.
  
 4)FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
  
 5)11-4.1.3(1) AT LEAST ONE ACCESSIBLE
 ROUTTE COMPLYING WITH 11-4.3 SHALL
 CONNECT ACCESSIBLE BUILDING OR FACILITY
 ENETRANCES WITH ALL ACCESSIBLE SPACES
 AND ELEMENTS WITHIN THE BUILDING OR
 FACILITY. INDICATE ACCESSIBILE ROUTE
 INTO BUILDING FOR THE HANDICAPPED?
  
 6) 11-4.13.5 CLEAR WIDTH, RESTROOM DOOR
 MINIMUM CLEAR WIDTH IS 32" WITH THE DOOR
 OPEN 90DEGREES MEASURED BETWEEN THE FACE
 OF THE DOOR AND THE OPPOSITE DOOR STOP.
  
 7) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING IS THE
 ROOFING REPORT.
  
 8) MISSING FLORIDA ENERGY COMPLIANCE
 FORM, METHOD C BUILDINGS LESS THAN 200
 SQ FT.
  
 9) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-05-15 Cont ID  
Sent By dpalmer Date 2002-05-15 Time 13:23 Rev Time 0.00
Received By dpalmer Date 2002-05-15 Time 13:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-06-05 Cont ID  
Sent By mcarsill Date 2002-06-05 Time 09:40 Rev Time 0.00
Received By mcarsill Date 2002-06-05 Time 09:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-06-27 Cont ID  
Sent By ndenmark Date 2002-06-27 Time 15:08 Rev Time 0.25
Received By ndenmark Date 2002-06-27 Time 15:08 Sent To  
Notes
2002-06-27 00:00:00MECHANICAL PERMIT REQUIRED BEFORE ANY
 MECHANICAL WORK COMMENCES INCLUDING
 DUCT FOR BATHROOM EXHAUST FAN

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-08-06 Cont ID  
Sent By kstevens Date 2002-08-06 Time 15:06 Rev Time 0.00
Received By kstevens Date 2002-08-06 Time 15:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-07-11 Cont ID  
Sent By kstevens Date 2002-07-11 Time 18:23 Rev Time 0.00
Received By kstevens Date 2002-07-11 Time 18:23 Sent To  
Notes
2002-07-11 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) COMMENTS NOT ADDRESSED FROM PREVIOUS
 REVIEW. SAME NOTE NUMBER AS FIRST REV.
  
 3) PLEASE SUBMIT DETAIL ON TOILET ROOM.
 SHOW LAV HEIGHT, TOILET HEIGHT. GRAB BAR
 HEIGHT AND LOCATION ECT.
 4) W/C SHALL BE 1'6" OFF WALL NOT 1'8"
 AS SHOWN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-05-25 Cont ID  
Sent By kstevens Date 2002-05-25 Time 15:45 Rev Time 0.00
Received By kstevens Date 2002-05-25 Time 15:45 Sent To  
Notes
2002-05-25 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 11
 FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM REQUIRED.
 2) WHERE WILL THE WATER SUPPLY AND SANI-
 TARY SEWER FACILITIES BE TIED INTO?
 3) PLEASE SUBMIT DETAIL ON TOILET ROOM.
 SHOW LAV HEIGHT, TOILET HEIGHT, GRAB BAR
 HEIGHT AND LOCATION ECT.
 4) W/C SHALL BE 1'6" OFF WALL NOT 1'8"
 AS SHOWN.
 5) SHOW COMPLIANCE WITH FBC SEC 1204.2
 NON ABSORBENT MATERIAL FOR WALLS AND
 FLOORS UP TO 4'.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-05-06 Cont ID  
Sent By sgraham Date 2002-05-06 Time 12:22 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***