| Plan Review Stops For Permit 02041954 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-04-08 |
Time |
13:22 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2003-04-08 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2003-04-08 00:00:00 | REVISION: ACCORDION SHUTTERS/ OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-02 |
Time |
13:57 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2003-03-26 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2003-03-26 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT:02041954 | | | ADD: 3390 TURTLE COVE | | | CONT: HOME DYNAMICS | | | TEL: (954) 275-8569 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | REVISION: ACCORDION SHUTTERS | | | ACTION: DENIED | | | | | | 1) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | 2)FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-10-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-15 |
Time |
11:51 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-10-15 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-09-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-10 |
Time |
11:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-09-10 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-08-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-12 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-08-12 |
Time |
06:32 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-05-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-20 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-20 |
Time |
09:58 |
Sent To |
R |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-02 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-02 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2003-04-02 00:00:00 | JW DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-03-12 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-12 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-12 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
| 2003-03-12 00:00:00 | SENT TO JW DESK - PRODUCT APPROVALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-06 |
Time |
17:55 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-21 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-21 |
Time |
18:05 |
Sent To |
M |
|
| Notes |
| 2002-11-21 00:00:00 | IN BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-02-14 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-14 |
Time |
16:26 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-02-14 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2003-02-14 00:00:00 | MECHANICAL PERMIT 02081247 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
17:56 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-11-26 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | MECHANICAL PERMIT 02111539 | | | CHG OF CONTR LTR & PERMIT APP FILE | | | W/02041954 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-07-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-21 |
Time |
18:05 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-07-20 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2002-07-20 00:00:00 | PASS/PROVISO | | | 1) NEED FRESH AIR CALCULATIONS FOR ROUGH | | | INSPECTION | | | 2) NEED PROGRAMMABLE T.STAT FOR FINAL | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-80969 EXT.8390 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-05-16 |
Time |
15:21 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-05-16 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2002-05-16 00:00:00 | PLAN DENIED | | | NO ENERGY CALCS OR MANUAL J | | | PLAN REVIEW BY HAROLD MOSER | | | [561]659-8096 EXT 8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-05-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-05-11 |
Time |
08:39 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-05-11 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2002-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-08 |
Time |
16:41 |
Rev Time |
0.10 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-08 00:00:00 | REVISION 8/31/02 ACCENT PIECES |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-08-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-08-12 |
Time |
15:27 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-08-12 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-06-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-08-12 |
Time |
07:37 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
2002-06-10 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2002-06-10 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 02041954 | | | ADD: LOT#49 SEC#5 RENAISSANCE | | | CONT: HOME DYNAMICS CONSTRUCTION | | | TEL: (954)275-8569 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | THE SAME COMMENTS AS LOT #48 02041957 | | | ANY QUESTIONS PLEASE CALL, | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | DEPARTMENT OF CONSTRUCTION SERVICES | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT. 8412 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-05-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-05-03 |
Time |
14:08 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|