| 2002-05-14 00:00:00 | BUILDING DENIED |
| | |
| | 1) THE 2001 FBC SECTION 1606.1.7 |
| | REQUIRES THE FOLLOWING INFORMATION TO BE |
| | SHOWN ON THE CONSTRUCTION DRAWINGS: |
| | - BASIC WIND SPEED, MPH. |
| | - WIND IMPORTANCE FACTOR(1) AND BUILDING |
| | CATEGORY. |
| | - WIND EXPOSURE- IF MORE THAN ONE WIND |
| | EXPOSURE IS USED THE WIND EXPOSURE AND |
| | APPLICABLE WIND DIRECTION SHALL BE |
| | INDICATED. |
| | - THE APPLICABLE INTERNAL PRESSURE |
| | COEFFICIENT |
| | - COMPONENTS AND CLADDING. THE DESIGN |
| | WIND PRESSURES IN TERMS OF PSF, TO BE |
| | USED FOR THE DESIGN OF EXTERIOR |
| | COMPONENT AND CLADDING MATERIALS NOT |
| | SPECIFICALLY DESIGNED BY THE REGISTERED |
| | DESIGN PROFESSIONAL. |
| | THE DESIGN CERTIFICATION FORM THAT WAS |
| | SUBMITTED IS NO LONGER ACCEPTABLE. IT |
| | ALSO WAS BASED ON THE 97 SBC WHICH WAS |
| | REPLACED BY THE 2001 FBC ON 3-1-02. |
| | |
| | 2)PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - ROOFING MATERIAL |
| | OR A SEPARATE PERMIT WILL BE REQUIRED |
| | WITH ADDITIONAL FEES. |
| | THE OWNER BUILDER IS REQUIRED TO SIGN |
| | THE BACK OF THE APPLICATION ON THE ROOF- |
| | ING CONTRACTOR LINE IF THEY WISH TO |
| | INCLUDE THE ROOFING WITH THE PERMIT. |
| | PLEASE INFORM THE PERMIT CLERK SO THAT A |
| | PERMIT NUMBER CAN BE GENERATED. |
| | |
| | IF YOU HAVE ANY QUESTIONS PLEASE CALL: |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |