| Plan Review Stops For Permit 02041445 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-06-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-06-05 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-05 00:00:00 | PLANS DATED 5/21/02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-08 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-08 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-06-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-05 |
Time |
06:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-05 |
Time |
06:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-06 |
Time |
20:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-06 |
Time |
20:35 |
Sent To |
|
|
| Notes |
| 2002-05-06 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT THE LOAD | | | CALCULATIONS NEED TO BE SHOWN. SQ FT/ | | | RECEPT LOADS ETC. PER 220-3,220-10, | | | 220-11, 220-13. (215-5) | | | | | | 2)NOTE: PLEASE NOTE THAT CIRCUIT #`S ON | | | PLANS AND PANEL SCHEDULES NEED TO | | | CORRELATE. PLEASE NOTE THAT THERE ARE | | | CIRCUITS ON PLANS THAT ARE SHOWN AS | | | "SPACE" ON SCHEDULE. THERE ARE CIRCUITS | | | SHOWN ON PLANS THAT DO NOT FIGURE UP TO | | | 180VA FOR RECEPTS PER 220-3B-9 | | | PLEASE GO OVER PLANS AND CORRELATE AND | | | LOAD CALCULATIONS NEED TO BE SHOWN NOT | | | JUST CONNECTED LOADS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-31 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-31 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-31 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-05-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-15 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-15 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2002-05-15 00:00:00 | 1) ANOTHER EXIT SIGN IS NEEDED IN | | | CORRIDOR 43, ADJACENT TO CRYPTO ROOM. | | | | | | 2) SECURITY DEVICES ON EXIT DOORS TO | | | COMPLY WITH DELAYED EGRESS OR ACCESS | | | CONTROLLED EGRESS DOORS. | | | | | | 3) INTERIOR FINISH CLASSIFICATIONS FOR | | | WALLS AND CEILINGS TO COMPLY WITH | | | APPLICABLE FIRE CODE VIOLATIONS. | | | | | | 4) IF FIRE SPRINKLERS ARE PRESENT, | | | SEPARATE PLANS AND PERMITS REQUIRED FOR | | | REMODEL. | | | | | | 5) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYTEM REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-28 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2002-05-28 |
Time |
14:23 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2002-05-28 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-06-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-21 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-21 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-15 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-15 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2002-06-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) PROVISIONS SHALL BE MADE FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING | | | AT THE DRINKING FOUNTAINS PER SECTION | | | 11-4.1.3(10) | | | 2) DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE FOR ANY FIXTURE. (NEW DRINK- | | | FOUNTAIN) SEC 11-4.17.5, 4.22.2, 4.23.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-05-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-15 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-15 |
Time |
19:21 |
Sent To |
|
|
| Notes |
| 2002-05-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT 2, PER TABLE 403.1 TWO DRINKING | | | FOUNTAINS ARE REQUIRED. SEE SEC 410.1 | | | 2) SHT 4, HDCP SHOWER. PLEASE SHOW COM- | | | PLIANCE FOR HDCP SHOWER PER SEC 11-4.21 | | | PROVIDE DETAILS FOR 11-4.21.2, 11-4.21.3 | | | 11-4.21.4, 11-4.21.5, 11-4.21.6 AND 11- | | | 4.21.7 | | | 3) SHT M1, WATER HEATER. PER SEC 504.7.1 | | | THE DISCHARGE PIPE SHALL NOT HAVE ANY | | | TRAPPED SECTIONS AND SHALL HAVE A VISI- | | | BLE AIR GAP OR AIR GAP FITTING LOCATED | | | IN THE SAME ROOM AS THE WATER HEATER. | | | 4) SHT M1, WATER HEATER. PAN DRAIN SHALL | | | BE A MINIMUM OF 3/4" AND SHALL BE IN- | | | DIRECTLY DRAINED TO A FLOOR SINK NOT A | | | FLOOR DRAIN. | | | 5) SHT M1, WATER ISOMETRIC. WATER HAMMER | | | ARRESTORS ARE REQUIRED WHERE QUICK CLOS- | | | ING VALVES ARE INSTALLED. (WASH MACHINES | | | ICE MAKER, DISHWASHERS ECT., IF INSTALL- | | | ED THEY SHALL BE LOCATED NEAR THE FIX- | | | TURE IN AN "EFFECTIVE RANGE" NOT AT TOP | | | OF THE DROP AS SHOWN. | | | 6) SHT M1, WATER ISOMETRIC. A MEANS OF | | | CONTROLING THERMAL EXPANSION MAY BE RE- | | | QUIRED PER SEC 607.3 | | | 7) SHT 3, WATER HEATER SHALL BE PLACED | | | SO AS TO PROVIDE AMPLE PROTECTION BET- | | | WEEN THE APPLIANCE AND ADJACENT CONBUST- | | | ABLE MATERIAL. NEC 422-17. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|