Plan Review Details - Permit 02041028
Plan Review Stops For Permit 02041028
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-06-27 Cont ID  
Sent By dpalmer Date 2002-06-27 Time 05:49 Rev Time 0.00
Received By dpalmer Date 2002-06-27 Time 05:49 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-05-06 Cont ID  
Sent By btrobaug Date 2002-05-06 Time 06:39 Rev Time 0.00
Received By dpalmer Date 2002-05-06 Time 05:58 Sent To R
Notes
2002-05-06 00:00:00~~~~~~~~~~~~~~~~~UNSAT!~~~~~~~~~~~~~~~~~
  
 1} PLEASE UPDATE THE ELECTRICAL NOTES ON
 SHEET E-2 TO REFLECT THE CURRENT
 (1999)NEC.
  
 2} PROVIDE RECEPTACLE AT A/C CONDENSORS
 PER 210-63.
  
 3} ADD A SMOKE DETECTOR IN THE DEN PER
 2-2.1.1.1 NFPA-72.
  
 4} ADD A SMOKE DETECTOR IN THE HALLWAY
 TO SERVE THE MASTER BEDROOM AND BEDROOM
 #2.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT.8392

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-11-21 Cont ID  
Sent By hmoser Date 2002-11-21 Time 17:39 Rev Time 0.50
Received By hmoser Date 2002-11-21 Time 17:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-27 Cont ID  
Sent By hmoser Date 2002-06-27 Time 17:34 Rev Time 0.50
Received By hmoser Date 2002-06-27 Time 17:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-05-02 Cont ID  
Sent By hmoser Date 2002-05-02 Time 17:24 Rev Time 0.33
Received By hmoser Date 2002-05-02 Time 17:24 Sent To  
Notes
2002-05-02 00:00:00PLAN DENIED
 EQUIPMENT NO PLANS DO NOT MATCH
 MANUAL J
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-04-27 Cont ID  
Sent By jleech Date 2002-04-27 Time 09:02 Rev Time 0.33
Received By jleech Date 2002-04-27 Time 09:02 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-05-21 Cont ID  
Sent By dpalmer Date 2002-06-27 Time 05:44 Rev Time 2.50
Received By lhatten Date 2002-05-19 Time 21:16 Sent To  
Notes
2002-05-21 00:00:00REVIEW & STAMPED PLANS 05/19/2002
 CALC. FEES & STAMPED PLANS 05/21/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-04-22 Cont ID  
Sent By sgraham Date 2002-04-22 Time 11:54 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved