Plan Review Details - Permit 02040876
| Plan Review Stops For Permit 02040876 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-04-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-04-30 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-30 00:00:00 | PROVISO:ARCHITECT MUST PROVIDE WRITTEN | | | VERIFICATION THAT DESIGN OF THIS PLAN | | | IS IN COMPLIANCE WITH THE 2001 FLORIDA | | | BUILDING CODE.ACCEPTANCE OF THIS | | | REVIEW NOT WITH STANDING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-26 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-26 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-29 |
Time |
20:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-29 |
Time |
20:29 |
Sent To |
|
|
| Notes |
| 2002-04-29 00:00:00 | *************** UNSAT ***************** | | | | | | 1 )NOTE: PLEASE NOTE THAT THE LOAD | | | CALCULATIONS NEED TO BE SHOWN. SQ FT/ | | | RECEPT LOADS ETC. PER 220-3,220-10, | | | 220-11, 220-13. (215-5) | | | PLEASE NOTE THAT ALL CONTINUOUS LOADS | | | NEED TO BE SHOWN AT 125%. 230-42/215-2,3 | | | | | | | | | 2)NOTE: PLEASE NOTE THAT WE ARE UNDER | | | THE "99" NEC. PLEASE NOTE TAHT PLANS | | | SHOW 1997? PLEASE ALSO NOTE THAT PLANS | | | SHOW WRONG CODES FOR OTHER TRADES. | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | | | | 3)NOTE: PLEASE NOTE TWO " 1TC" PANELS | | | SHOWN ON MDP. (MISPRINT) | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 5661-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-17 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-17 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-05-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-10 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-10 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-05-25 |
Time |
10:46 |
Rev Time |
0.75 |
| Received By |
hmoser |
Date |
2002-05-25 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2002-05-25 00:00:00 | CALLED LEFT MESSAGE TO PICKUP PLANS. | | | PLANS IN BOX I | | | H.M. 5/25/02 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-06 |
Time |
05:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-06 |
Time |
05:24 |
Sent To |
|
|
| Notes |
| 2002-07-06 00:00:00 | PASSED/PROVISO | | | | | | ALL WATER HAMMER ARRESTORS SHALL BE LO- | | | CATED NEAR FIXTURES - NOT AT TOP OF DROP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-05-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-11 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-11 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2002-05-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT A-0.1 APPLICABLE CODE ARE NOT | | | STANTARD CODES BUT FLA. BLDG. CODES. | | | PLEASE CHANGE REFERENCE. | | | 2) SHT A-2.2 DRINKING FOUNTAIN, EITHER | | | HI-LOW DRINKING FOUNTAIN OR OTHER PROVI- | | | SIONS FOR THOSE WHO HAVE DIFFICULTY | | | BENDING OR STOOPING PER FBC 11-4.1.3(10) | | | 3) SHT P-1 WATER RISER DIAGRAM, AIR | | | CHAMBERS NOT APPROVED. WATER HAMMER ARR- | | | ESTORS ARE REQUIRED FOR QUICK CLOSING | | | VALVES (DISHWASHERS, ICE MAKERS, WASH | | | MACHINES ECT). IF USED THEY SHALL BE LO- | | | CATED NEAR THE FIXTURE IN AN "EFFECTIVE | | | RANGE" NOT AT TOP OF DROPS AS SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
|