Plan Review Details - Permit 02040166
Plan Review Stops For Permit 02040166
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-04-15 Cont ID  
Sent By hpiskura Date 2003-04-15 Time 10:23 Rev Time 0.00
Received By hpiskura Date 2003-04-15 Time 10:23 Sent To  
Notes
2003-04-15 00:00:00SAME PLANS AS 2/4/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-02-04 Cont ID  
Sent By hpiskura Date 2003-02-04 Time 09:04 Rev Time 0.00
Received By hpiskura Date   Time 10:24 Sent To  
Notes
2003-02-04 00:00:00REVISIONS DATED 1/15/03 JLSD

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-07-31 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 12:12 Rev Time 0.00
Received By hpiskura Date   Time   Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-05-07 Cont ID  
Sent By hpiskura Date 2002-05-07 Time 12:06 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-01-30 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 11:40 Rev Time 1.00
Received By btrobaug Date 2003-01-29 Time 12:51 Sent To  
Notes
2003-01-30 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 THE ELECTRICAL SHEETS SUBMITTED AS A
 REVISION OF PERMIT #2040166 DO NOT
 MATCH THE SHEETS ORIGINALLY PERMITTED
 UNDER THAT NUMBER.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-08-20 Cont ID  
Sent By btrobaug Date 2002-08-20 Time 14:41 Rev Time 0.00
Received By btrobaug Date 2002-08-20 Time 14:41 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-07-23 Cont ID  
Sent By dpalmer Date 2002-07-23 Time 18:27 Rev Time 0.00
Received By dpalmer Date 2002-07-23 Time 18:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-29 Cont ID  
Sent By dpalmer Date 2002-04-29 Time 10:28 Rev Time 0.00
Received By dpalmer Date 2002-04-29 Time 10:28 Sent To  
Notes
2002-04-29 00:00:00***************** UNSAT **************
  
 1)NOTE: PLEASE NOTE, LOAD CALCAULTIONS
 AND THINGS FROM THE MAIN ELECTRICAL
 PLANS HAVE NOT PASSED AND NEED TO BE
 ADDRESSED BEFORE THE SERVICE CAN BE
 PASSED.
  
 2)NOTE: PLEASE NOTE THAT COLOR CODING
 FROM SPEC BOOKS NEED TO MEET LOCAL CODE
 FOR 277/ 480VBROWN/PURPLE/YELLOW.
 PLEASE ALSO NOTE CODE ARTS REFERENCED
 FROM THE 96 NEC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. PLEASE NOTE MAIN ELECTRICAL
 PLANS NEED TO HAVE COMMENTS ADDRESSED.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-05-07 Cont ID  
Sent By mcarsill Date 2002-05-07 Time 14:09 Rev Time 0.00
Received By mcarsill Date 2002-05-07 Time 14:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-18 Cont ID  
Sent By sthyng Date 2003-03-18 Time 13:59 Rev Time 0.00
Received By sthyng Date 2003-03-18 Time 13:59 Sent To  
Notes
2003-03-18 00:00:00COMM BOARD #40

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-30 Cont ID  
Sent By btrobaug Date 2003-01-30 Time 14:28 Rev Time 0.00
Received By btrobaug Date 2003-01-22 Time 14:28 Sent To  
Notes
2003-01-30 00:00:00COM BOARD#63./WRT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-04-10 Cont ID  
Sent By pkrauss Date 2003-04-10 Time 08:18 Rev Time 0.45
Received By pkrauss Date 2003-04-10 Time 08:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-08-08 Cont ID  
Sent By btrobaug Date 2002-08-20 Time 14:41 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2003-04-07 Cont ID  
Sent By kstevens Date 2003-04-07 Time 06:52 Rev Time 0.75
Received By kstevens Date 2003-04-07 Time 06:52 Sent To  
Notes
2003-04-07 00:00:00NO CHANGES TO PLUMBING NOTED

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-07-20 Cont ID  
Sent By kstevens Date 2002-07-20 Time 15:29 Rev Time 0.00
Received By kstevens Date 2002-07-20 Time 15:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-05-01 Cont ID  
Sent By kstevens Date 2002-05-01 Time 16:53 Rev Time 0.00
Received By kstevens Date 2002-05-01 Time 16:52 Sent To  
Notes
2002-05-01 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) IRRIGATION PLANS SHALL CALL OUT THE
 CONTROL PANEL, RAIN SENSOR, AND IF ON
 CITY WATER THE BACKFLOW. IF TIED TO
 EXISTING SYSTEM SHOW WHERE THE TIE IN IS
 LOCATED AS WELL AS INFORMATION REQUESTED
 ABOVE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2002-08-08 Cont ID  
Sent By hpiskura Date 2002-07-31 Time 11:16 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2002-08-08 00:00:00ZONING APPROVED SEE PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status F Date 2002-04-16 Cont ID  
Sent By sgraham Date 2002-04-16 Time 09:20 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-04-16 00:00:00NEED LANDSCAPE PLAN