| Plan Review Stops For Permit 02031690 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-04-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-04-15 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-05-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-21 |
Time |
19:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-21 |
Time |
19:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-11 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-11 |
Time |
06:49 |
Sent To |
|
|
| Notes |
| 2002-04-11 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT TWO DIFFERENT | | | E-SHEETS WERE SUBMITTED? PLEASE NOTE | | | THAT BOTH HAVE THE SAME DATE AND ARE | | | NOT DATED BY ARCH? PLEASE ONLY SUBMIT | | | THE LATEST ONE TO BE REVIEWED. | | | | | | 2)NOTE: PLEASE NOTE THAT ALL BRANCH | | | CIRCUITING #`S ARE TO BE SHOWN ON PLANS | | | AND CORRELATE WITH A SUBMITTED PANEL | | | SCHEDULE. | | | | | | 3)NOTE: PLEASE SHOW SIZE OF EXISTING | | | PANEL IN ORDER TO VERIFY LOAD TO SERVICE | | | SIZE. | | | | | | 4)NOTE: PLEASE NOTE MISSING SHOW WINDOW | | | OUTLETS PER 210-62 | | | | | | 5)NOTE: PLEASE CLARIFY REQ`D SIGN | | | CIRCUIT PER 600-5. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-05-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-05-13 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-17 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-17 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-04-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-04-04 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-04-04 |
Time |
17:04 |
Sent To |
|
|
| Notes |
| 2002-04-04 00:00:00 | A) FIRE SPRINKLER HEADS REQUIRED IN | | | REFRIGERATOR AND FREEZER. | | | B) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR WALLS | | | AND CEILINGS. | | | C) PLEASE PROVIDE INFORMATION ON | | | DUKE OVEN. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-28 |
Time |
16:20 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-05-28 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-10 |
Time |
12:00 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-04-10 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2002-04-10 00:00:00 | | | | | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS AS | | | PER 2001 FBC, MECHANICAL TABLE | | | 403.3 OR ASHRAE 62-89. | | | | | | 2.PROVIDE MANUFACTURER SUBMITTAL DATA | | | OVEN. | | | | | | 3.PROVIDE MANUFACTURER INFORMATION | | | FOR THE NEW 4 TON RTU. (MAKE, MODEL | | | BTU, SEER). | | | | | | 4.INDICATE CFM DISTRIBUTION ON PLAN. | | | | | | 3.ADDITIONAL PERMITS REQUIRED FOR WALK | | | IN FREEZER/COOLER, HOOD AND FIRE | | | SUPRESSION.PLEASE PROVIDE PLANS & | | | MANUFACTURER SUBMITTAL DATA WITH | | | PERMIT APPLILCATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-06-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-06-01 |
Time |
13:31 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2002-06-01 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-04-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-04-30 |
Time |
17:33 |
Rev Time |
2.00 |
| Received By |
jleech |
Date |
2002-04-30 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2002-04-30 00:00:00 | DENIED; | | | 1.WOMENS TOILET ROOM DOES NOT MEET | | | MINIMUM INSIDE WIDTH. | | | 2.URINAL TO MEET FACBC REQUREMENTS SEE | | | SEC 11-4.18.1 THRU11-4.18.4. SHOW | | | DETAIL ON DRAWING. | | | 3.GREASE TRAP TO BE SIZED AND LOCATED BY | | | RODNEY COMPO UTILITY DEPARTMENT PHONE | | | 837-4074 SPECIFICATIONS WILL BE | | | REQUIRED, SIZE MANUFACTOR, CERTIFIED | | | BY ETC. | | | 4.ALL INDIRECT WASTE TO FLOOR SINKS ICE | | | MAKER, SODA DISPENSOR ETC. | | | 5.HOT WATER TO HAND SINKS AND LAVITORIES | | | TO BE 110 DEG. IF HOTTER WATER IS | | | REQUIRED FOR 3 COMPARTMENT SINK SHOW | | | TEMPORING VALVE. | | | 6.SHOCK ARRESTORS REQUIRED WITH SEC. | | | 604.9. | | | 7.PAGE M2.0 RISER DIAGRAM. SHOW CLEAR | | | SEPORATION OF GREASY WASTE AND | | | SANITARY PIPING. W/C AND URINAL CANNOT | | | GO THRU GREASE TRAP. | | | 8.WHAT TYPE FIXTURE IS ABOVE URINAL. NOT | | | MARKED. | | | 9.FLOOR DRAINS REQUIRED WITH TRAP PRIMER | | | IN REST ROOMS. | | | | | | 10.RISER DIAGRAM SHOWS 3 LAVS AND 3 W/C | | | AND MISSING SERVICE SINK. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2002-05-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-05-13 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|