Plan Review Details - Permit 02031521
Plan Review Stops For Permit 02031521
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-04-19 Cont ID  
Sent By btrobaug Date 2002-04-19 Time 14:15 Rev Time 0.00
Received By btrobaug Date 2002-04-19 Time 14:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-04-15 Cont ID  
Sent By btrobaug Date 2002-04-15 Time 07:13 Rev Time 0.00
Received By btrobaug Date 2002-04-15 Time 06:38 Sent To  
Notes
2002-04-15 00:00:00******************UNSAT!****************
 1)NOTE: PLEASE NOTE THAT ALL PLANS
 THAT ARE SIGNED AND SEALED BY ARCH/ OR
 ENGINEER ARE REQ`D PER 61G15-23.002 FOR
 ENGINEER AND 61G1-16.004 FOR ARCH.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-09 Cont ID  
Sent By btrobaug Date 2002-04-09 Time 15:05 Rev Time 0.00
Received By btrobaug Date 2002-04-09 Time 15:05 Sent To FIRE
Notes
2002-04-09 00:00:00*****************UNSAT******************
  
 PLEASE GIVE NAMEPLATE RATINGS OF
 EQUIPMENT AND HOW BEING FED,ALSO LOW
 VOLTAGE FEEDS TO BE SHOWN ON DRAWINGS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-05-10 Cont ID  
Sent By mcarsill Date 2002-05-10 Time 13:40 Rev Time 0.00
Received By mcarsill Date 2002-05-10 Time 13:40 Sent To  
Notes
2002-05-10 00:00:001) PLEASE BE ADVISED THAT A MINIMUM OF
 AT LEAST SEVEN AND HALF FEET CLEARANCE
 IS REQUIRED TO THE FRONT AND SIDES OF A
 FIRE HYDRANT. FOUR FEET IS REQUIRED TO
 THE REAR OF THE HYDRANT. EQUIPMENT FOR
 THE GATE CANNOT INTERFERE WITH THESE
 REQUIREMENTS.
  
 2) APPROPRIATE SIGNAGE IS REQUIRED FOR
 THE GATE THAT FIRE RESCUE IS EXPECTED
 TO USE ON THE NORTH SIDE.
  
 3) ALL OPENINGS THAT FIRE RESCUE ARE
 EXPECTED TO USE MUST BE AT LEAST
 TWENTY FEET IN CLEAR WIDTH.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-04-10 Cont ID  
Sent By mcarsill Date 2002-04-10 Time 12:28 Rev Time 0.00
Received By mcarsill Date 2002-04-10 Time 12:28 Sent To  
Notes
2002-04-10 00:00:00A) WHAT PROVISIONS HAVE BEEN MADE FOR
 FIRE AND PARAMEDICAL ACCESS. THE CUT
 SHEET BOOKLET DOES CONTAIN KNOX-BOX
 KEY SWITCH INFORMATION BUT IS IT
 SPECIFIC FOR THIS JOB.
 B) WHAT PROVISIONS HAVE BEEN MADE FOR
 THE SECURITY DEVICES IF ELECTRICAL
 POWER IS LOST. ARE THE SECURITY
 EQUIPMENT FAIL SAFE OR FAIL SECURE.
 C) THE NEW EQUIPMENT DOES NOT ALLOW
 FOR 20 FEET IN CLEAR WIDTH. THE NEW
 SECURITY FEATURES MUST BE PROPER IN
 DESIGN AND FUNCTION AS THE EXISTING
 EQUIPMENT DID NOT MEET NEEDS OF THE
 FIRE RESCUE DEPARTMENT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop Z ZONING
Rev No 2 Status P Date 2002-04-09 Cont ID  
Sent By sgraham Date 2002-04-09 Time 11:45 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-04-04 Cont ID  
Sent By sgraham Date 2002-04-04 Time 08:21 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***