Plan Review Details - Permit 02031481
Plan Review Stops For Permit 02031481
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-06-29 Cont ID  
Sent By jwitmer Date 2002-06-29 Time 11:06 Rev Time 0.50
Received By jwitmer Date 2002-06-29 Time 11:06 Sent To  
Notes
2002-06-29 00:00:00LETTER INDICATING THE USE OF ALT WALL
 DETAIL!

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-13 Cont ID  
Sent By jwitmer Date 2002-05-13 Time 13:38 Rev Time 1.00
Received By jwitmer Date 2002-05-13 Time 13:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-16 Cont ID  
Sent By jwitmer Date 2002-04-16 Time 12:51 Rev Time 2.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-04-16 00:00:00BUILDING PLAN REVIEW
 PERMIT# 02031481
 2541 METROCENTRE BLVD
 CONT: WALTON EFFORT INC
 TEL: 478-4457
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)- THE TYPE OF OCCUPANCY IS NOT CLEAR,
 WHAT TYPE OF BUSINESS IS GOING TO OCCU-
 PY THIS SPACE? IS THIS A BUSINESS THAT
 WILL REQUIRE PATEINTS TO SLEEP OVER-
 NIGHT? WILL THERE BE ATTENDANTS?
 WHAT DOES PT/RT AREA STAND FOR?
 2)- WHAT TYPE OF OCCUPANCIES ARE ON EITH
 ER SIDE OF THIS SPACE?
 3)- DOOR #4 WHAT DOES THIS DOOR GO TO?
 DOES IT GO TO ANOTHER TENANT SPACE? IS
 THIS A REQUIRED EGRESS DOOR FROM ANOTHER
 TENANTSPACE?
 4)- FL BLD CODE 11-4.1.1(2) APPLICATION
 BASED ON BUILDING USE, SPECIAL APPLICATI
 ON USE 11.6 FOR MEDICAL CARE FACILITIES
 MAY BE REQUIRED DEPENDING ON THE ANSWERS
 TO THE ABOVE QUESTIONS.
 5)- FL BLD CODE 11.4.21.3 SEAT VS CON-
 TROLS THE SEAT SHALL BE ON THE WALL
 OPPOSITE THE CONTROLS.
 6)- THESE PLANS ARE INADEQUITE TO DO A
 THOROUGH REVIEW UNTIL THE QUESTIONS
 ABOVE ARE ANSWERED.
 JIM WITMER
 (561)659-8096EXT8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-05-29 Cont ID  
Sent By dpalmer Date 2002-05-29 Time 18:26 Rev Time 0.00
Received By dpalmer Date 2002-05-29 Time 18:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2002-05-07 Cont ID  
Sent By dpalmer Date 2002-05-07 Time 18:10 Rev Time 0.00
Received By dpalmer Date 2002-05-07 Time 18:10 Sent To  
Notes
2002-05-07 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE AFTER REVIEW OF
 PLANS, NOTE #3 FROM FIRST REVIEW HAS
 NOT BEEN ADDRESSED AND LOAD ON SOME
 CIRCUITS DO NOT CORRELATE WITH THE
 AMOUNTS SHOWN ON PLANS.
  
 2)NOTE: PLEASE ALSO NOTE THAT THERE
 ARE MANY CIRCUIT #`S ON PLANS THAT DO
 NOT CORRELATE WITH PANEL SCHEDULES
 SUBMITTED. PLEASE NOTE SOME LOADING OF
 CIRCUTIS ALSO DO NOT CORRELATE WITH THE
 AMOUNT OF RECEPTS ETC ON CIRCUITS? AND
 PANEL SCHEDULES?
  
 PLEASE SEE NOTE (3) FROM FIRST REVIEW
 AND SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-03 Cont ID  
Sent By dpalmer Date 2002-04-03 Time 15:35 Rev Time 0.00
Received By dpalmer Date 2002-04-03 Time 15:34 Sent To  
Notes
2002-04-03 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE CLARIFY IF MAIN DISC`S
 SHOWN ARE NEW OR ALSO EXSITING? IF NEW
 PLEASE SUBMIT AIC RATING FOR MAINS.110-9
  
 2)NOTE: PLEASE CLARIFY HOW PANELS "B"
 AND "D" ARE FED?? ARE FROM FEED THRU
 LUGS FROM PANELS A, C? OR ARE THEY FED
 FROM OCP IN PANELS "A AND "C"??
  
 3)NOTE: PLEASE SHOW LOAD CALCULATIONS,
 PLANS ARE SHOWING NEW LOADS, AND
 EVERYTHING IS SHOWN AS CONNECTED LOAD.
 220-3,220-10,220-11,220-13.
  
 PLEASE SUBMIT THE ABOVE INFORMATION/
 CLARIFICATION FOR REVIEW. IF THERE ARE
 ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-04-26 Cont ID  
Sent By lmartine Date 2002-04-26 Time 17:46 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-05-10 Cont ID  
Sent By mcarsill Date 2002-05-10 Time 15:58 Rev Time 0.00
Received By mcarsill Date 2002-05-10 Time 15:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-03-28 Cont ID  
Sent By mcarsill Date 2002-03-28 Time 15:03 Rev Time 0.00
Received By mcarsill Date 2002-03-28 Time 15:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-07-31 Cont ID  
Sent By pkrauss Date 2002-07-31 Time 09:24 Rev Time 0.35
Received By pkrauss Date 2002-07-31 Time 09:24 Sent To  
Notes
2002-07-31 00:00:00REVISION - SUBMITTAL LTR FROM A. CHANE
 REMOVING HIMSELF AS ENGINEER OF RECORD
 FOR THE MECH.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-05-31 Cont ID  
Sent By pkrauss Date 2002-05-31 Time 14:03 Rev Time 0.35
Received By pkrauss Date 2002-05-31 Time 14:03 Sent To  
Notes
2002-05-31 00:00:00RE-STAMP NOT A REVISION.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-07 Cont ID  
Sent By pkrauss Date 2002-05-07 Time 09:33 Rev Time 0.35
Received By pkrauss Date 2002-05-07 Time 09:33 Sent To  
Notes
2002-05-07 00:00:00PROVISO ON PLAN

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-04-10 Cont ID  
Sent By pkrauss Date 2002-04-10 Time 16:10 Rev Time 0.50
Received By pkrauss Date 2002-04-10 Time 13:50 Sent To  
Notes
2002-04-10 00:00:002001 FLORIDA BUILDING CODE, MECHANICAL
  
 1.PLEASE PROVIDE MANUFACTURER
 INFORMATION FOR THE NEW AHU.
  
 2.PROVIDE OUTSIDE AIR CALCULATIONS AS
 PER 2001 FBC, MECH TABLE 403.3 OR
 ASHRAE 62-89.
  
 3.SHOW COMPLIANCE WITH 2001 FBC, MECH
 601.4, PRESSURE DIFFERENTIALS ACROSS
 CLOSED DOORS WHERE RETURNS ARE
 CENTRALLY LOCATED SHALL BE LIMITED
 TO .001 INCH WC OR LESS.PROVIDE
 AIR DUCT PATHWAY OR AIR TRANSFER
 PATHWAYS FROM THE HIGH PRESSURE ZONE
 TO THE LOW ZONE.
  
 4.CONDENSATE SHALL DISCHARGE A MINIMUM
 OF 12 INCHES AWAT FROM THE BUILDING
 STRUCTURE AS PER 2001 FBC 1503.4.4.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 5 Status P Date 2002-07-02 Cont ID  
Sent By jleech Date 2002-07-02 Time 16:56 Rev Time 0.50
Received By jleech Date 2002-07-02 Time 16:56 Sent To  
Notes
2002-07-02 00:00:00DELETED SEVICE SINK AND ADDED A LAUNDRY
 TUB.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-06-03 Cont ID  
Sent By kstevens Date 2002-06-03 Time 17:07 Rev Time 0.00
Received By kstevens Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-06-03 Cont ID  
Sent By kstevens Date 2002-06-03 Time 17:06 Rev Time 0.00
Received By kstevens Date 2002-06-03 Time 17:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-05-17 Cont ID  
Sent By kstevens Date 2002-05-17 Time 09:41 Rev Time 0.00
Received By kstevens Date 2002-05-17 Time 09:41 Sent To  
Notes
2002-05-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW: SHT A-1 DRINK-
 ING FOUNTAIN, SECTION 4.1.3(10) PLEASE
 SHOW COMPLIANCE FOR THOSE WHO HAVE DIFF
 ICULTY BENDING OR STOOPING.
 2) FROM PREVIOUS REVIEW: SHT M-1 PLUMB-
 ING PLAN AND SANT RISER DIAGRAM, FLOOR
 DRAIN NOT APPROVED FOR INDIRECT WASTE
 FOR WATER HEATER T/P RELIEF DISCHARGE.
 FLOOR SINK REQUIRED FOR ALL INDIRECT
 WASTE, AND A TRAP PRIMER IS REQUIRED TO
 PROTECT SEAL OF TRAP. SEC 802.3
 3) SERVICE SINK IS REQUIRED PER TABLE
 403.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-04-24 Cont ID  
Sent By kstevens Date 2002-04-24 Time 22:44 Rev Time 0.00
Received By kstevens Date 2002-04-24 Time 22:44 Sent To  
Notes
2002-04-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING/CHAPTER 11
  
 1) PLEASE INDICATE USAGE FOR TENANT
 SPACE TO PROPERLY CALCULATE MINIMUM FAC-
 ILITIES.
 2) PROVIDE CALCULATIONS FOR MINIMUM FAC-
 ILITIES.
 3) SHT A-1 DRINKING FOUNTAIN, SECTION
 4.1.3(10) PLEASE SHOW COMPLIANCE FOR
 THOSE WHO HAVE DIFFICULTY BENDING OR
 STOOPING.
 4) SHT M-1 PLUMBING PLAN AND SANT RISER
 DIAGRAM, FLOOR DRAIN NOT APPROVED FOR
 INDIRECT WASTE FOR WATER HEATER T/P.
 FLOOR SINK REQUIRED FOR ALL INDIRECT
 WASTE, AND TRAP PRIMER REQUIRED TO PRO-
 TECT SEAL OF TRAP. SECTION 802.3
 5) IN MOST OCCUPANCIES A SERVICE SINK IS
 REQUIRED UNDER THE FBC-2001 MINIMUM FAC-
 ILITIES.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2002-04-26 Cont ID  
Sent By lmartine Date 2002-04-26 Time 17:50 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***