| Plan Review Stops For Permit 02031481 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-06-29 |
Time |
11:06 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-06-29 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2002-06-29 00:00:00 | LETTER INDICATING THE USE OF ALT WALL | | | DETAIL! |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-05-13 |
Time |
13:38 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-05-13 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-04-16 |
Time |
12:51 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-16 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT# 02031481 | | | 2541 METROCENTRE BLVD | | | CONT: WALTON EFFORT INC | | | TEL: 478-4457 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1)- THE TYPE OF OCCUPANCY IS NOT CLEAR, | | | WHAT TYPE OF BUSINESS IS GOING TO OCCU- | | | PY THIS SPACE? IS THIS A BUSINESS THAT | | | WILL REQUIRE PATEINTS TO SLEEP OVER- | | | NIGHT? WILL THERE BE ATTENDANTS? | | | WHAT DOES PT/RT AREA STAND FOR? | | | 2)- WHAT TYPE OF OCCUPANCIES ARE ON EITH | | | ER SIDE OF THIS SPACE? | | | 3)- DOOR #4 WHAT DOES THIS DOOR GO TO? | | | DOES IT GO TO ANOTHER TENANT SPACE? IS | | | THIS A REQUIRED EGRESS DOOR FROM ANOTHER | | | TENANTSPACE? | | | 4)- FL BLD CODE 11-4.1.1(2) APPLICATION | | | BASED ON BUILDING USE, SPECIAL APPLICATI | | | ON USE 11.6 FOR MEDICAL CARE FACILITIES | | | MAY BE REQUIRED DEPENDING ON THE ANSWERS | | | TO THE ABOVE QUESTIONS. | | | 5)- FL BLD CODE 11.4.21.3 SEAT VS CON- | | | TROLS THE SEAT SHALL BE ON THE WALL | | | OPPOSITE THE CONTROLS. | | | 6)- THESE PLANS ARE INADEQUITE TO DO A | | | THOROUGH REVIEW UNTIL THE QUESTIONS | | | ABOVE ARE ANSWERED. | | | JIM WITMER | | | (561)659-8096EXT8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-05-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-29 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-29 |
Time |
18:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-05-07 |
Time |
18:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-05-07 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2002-05-07 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE AFTER REVIEW OF | | | PLANS, NOTE #3 FROM FIRST REVIEW HAS | | | NOT BEEN ADDRESSED AND LOAD ON SOME | | | CIRCUITS DO NOT CORRELATE WITH THE | | | AMOUNTS SHOWN ON PLANS. | | | | | | 2)NOTE: PLEASE ALSO NOTE THAT THERE | | | ARE MANY CIRCUIT #`S ON PLANS THAT DO | | | NOT CORRELATE WITH PANEL SCHEDULES | | | SUBMITTED. PLEASE NOTE SOME LOADING OF | | | CIRCUTIS ALSO DO NOT CORRELATE WITH THE | | | AMOUNT OF RECEPTS ETC ON CIRCUITS? AND | | | PANEL SCHEDULES? | | | | | | PLEASE SEE NOTE (3) FROM FIRST REVIEW | | | AND SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-03 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-03 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2002-04-03 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE CLARIFY IF MAIN DISC`S | | | SHOWN ARE NEW OR ALSO EXSITING? IF NEW | | | PLEASE SUBMIT AIC RATING FOR MAINS.110-9 | | | | | | 2)NOTE: PLEASE CLARIFY HOW PANELS "B" | | | AND "D" ARE FED?? ARE FROM FEED THRU | | | LUGS FROM PANELS A, C? OR ARE THEY FED | | | FROM OCP IN PANELS "A AND "C"?? | | | | | | 3)NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLANS ARE SHOWING NEW LOADS, AND | | | EVERYTHING IS SHOWN AS CONNECTED LOAD. | | | 220-3,220-10,220-11,220-13. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION/ | | | CLARIFICATION FOR REVIEW. IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-04-26 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-10 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-10 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-03-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-03-28 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-03-28 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-07-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-07-31 |
Time |
09:24 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-07-31 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2002-07-31 00:00:00 | REVISION - SUBMITTAL LTR FROM A. CHANE | | | REMOVING HIMSELF AS ENGINEER OF RECORD | | | FOR THE MECH. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-05-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-31 |
Time |
14:03 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-05-31 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2002-05-31 00:00:00 | RE-STAMP NOT A REVISION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-07 |
Time |
09:33 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-05-07 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2002-05-07 00:00:00 | PROVISO ON PLAN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-10 |
Time |
16:10 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-04-10 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2002-04-10 00:00:00 | 2001 FLORIDA BUILDING CODE, MECHANICAL | | | | | | 1.PLEASE PROVIDE MANUFACTURER | | | INFORMATION FOR THE NEW AHU. | | | | | | 2.PROVIDE OUTSIDE AIR CALCULATIONS AS | | | PER 2001 FBC, MECH TABLE 403.3 OR | | | ASHRAE 62-89. | | | | | | 3.SHOW COMPLIANCE WITH 2001 FBC, MECH | | | 601.4, PRESSURE DIFFERENTIALS ACROSS | | | CLOSED DOORS WHERE RETURNS ARE | | | CENTRALLY LOCATED SHALL BE LIMITED | | | TO .001 INCH WC OR LESS.PROVIDE | | | AIR DUCT PATHWAY OR AIR TRANSFER | | | PATHWAYS FROM THE HIGH PRESSURE ZONE | | | TO THE LOW ZONE. | | | | | | 4.CONDENSATE SHALL DISCHARGE A MINIMUM | | | OF 12 INCHES AWAT FROM THE BUILDING | | | STRUCTURE AS PER 2001 FBC 1503.4.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2002-07-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-07-02 |
Time |
16:56 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2002-07-02 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2002-07-02 00:00:00 | DELETED SEVICE SINK AND ADDED A LAUNDRY | | | TUB. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-06-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-03 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-06-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-03 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-03 |
Time |
17:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-17 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-17 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2002-05-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: SHT A-1 DRINK- | | | ING FOUNTAIN, SECTION 4.1.3(10) PLEASE | | | SHOW COMPLIANCE FOR THOSE WHO HAVE DIFF | | | ICULTY BENDING OR STOOPING. | | | 2) FROM PREVIOUS REVIEW: SHT M-1 PLUMB- | | | ING PLAN AND SANT RISER DIAGRAM, FLOOR | | | DRAIN NOT APPROVED FOR INDIRECT WASTE | | | FOR WATER HEATER T/P RELIEF DISCHARGE. | | | FLOOR SINK REQUIRED FOR ALL INDIRECT | | | WASTE, AND A TRAP PRIMER IS REQUIRED TO | | | PROTECT SEAL OF TRAP. SEC 802.3 | | | 3) SERVICE SINK IS REQUIRED PER TABLE | | | 403.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-04-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-04-24 |
Time |
22:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-04-24 |
Time |
22:44 |
Sent To |
|
|
| Notes |
| 2002-04-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING/CHAPTER 11 | | | | | | 1) PLEASE INDICATE USAGE FOR TENANT | | | SPACE TO PROPERLY CALCULATE MINIMUM FAC- | | | ILITIES. | | | 2) PROVIDE CALCULATIONS FOR MINIMUM FAC- | | | ILITIES. | | | 3) SHT A-1 DRINKING FOUNTAIN, SECTION | | | 4.1.3(10) PLEASE SHOW COMPLIANCE FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | 4) SHT M-1 PLUMBING PLAN AND SANT RISER | | | DIAGRAM, FLOOR DRAIN NOT APPROVED FOR | | | INDIRECT WASTE FOR WATER HEATER T/P. | | | FLOOR SINK REQUIRED FOR ALL INDIRECT | | | WASTE, AND TRAP PRIMER REQUIRED TO PRO- | | | TECT SEAL OF TRAP. SECTION 802.3 | | | 5) IN MOST OCCUPANCIES A SERVICE SINK IS | | | REQUIRED UNDER THE FBC-2001 MINIMUM FAC- | | | ILITIES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2002-04-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2002-04-26 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|