Plan Review Details - Permit 02031298
Plan Review Stops For Permit 02031298
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-11 Cont ID  
Sent By jwitmer Date 2002-06-11 Time 11:49 Rev Time 0.75
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-18 Cont ID  
Sent By jwitmer Date 2002-04-18 Time 10:16 Rev Time 2.00
Received By jwitmer Date 2002-04-18 Time 10:16 Sent To  
Notes
2002-04-18 00:00:00BUILDING PLAN REVIEW
 PERMIT # 02031298
 4310 SAN MARINO BLVD
 CONT: ALLIANCE
 TEL: (561) 242-5613
  
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1)- RESIDENT INSPECTOR PROGRAM, 3 SETS
 OF PLANS REQUIRED, LANDSCAPE DRAWINGS
 ONLY 2 COPIES REQUIRE A THIRD APPROVED
 PLAN.
 2)- FL BLD CODE 1606.1.7 INFORMATION
 MISSING RELATED TO WIND, SEE NEW CODE!!!
 3)- FL BLD CODE 1606.1.4 PROTECTION OF
 OPENINGS, PRODUCT APPROVALS (3 SETS)
 FOR ALL GLAZED OPENINGS,EITHER
 STORM SHUTTERS OR LARGE MISSLE
 IMPACT GLAZING, SBCCI OR DADE REPORT!
 4)- FLBLD CODE 1707.5 CONCRETE ROOF TILE
 REQUIRES (3) PRODUCT APPROVAL FOR
 WIND ZONE.
 5)- FL BLD CODE 1804.1.3 THE BOTTOM OF
 THE FOUNDATION SHALL BE NO LESS THAN 12"
 BELOW FINISH GRADE.
 6)- SHEET AM-2 INDICATES SEMCO STRAPS,
 NO LONGER IN BUSINESS!
 7)- CONTRACTOR TO SUBMIT PLANS TO P. B.
 COUNTY FOR IMPACT FEE ASSESSMENT.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-11-14 Cont ID  
Sent By btrobaug Date 2002-11-14 Time 18:11 Rev Time 0.00
Received By btrobaug Date 2002-11-14 Time 18:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-04-25 Cont ID  
Sent By dpalmer Date 2002-04-25 Time 06:16 Rev Time 0.00
Received By dpalmer Date 2002-04-25 Time 06:16 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-03-21 Cont ID  
Sent By pkrauss Date 2002-03-21 Time 08:40 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-05-07 Cont ID  
Sent By mcarsill Date 2002-05-07 Time 15:08 Rev Time 0.00
Received By mcarsill Date 2002-05-07 Time 15:08 Sent To  
Notes
2002-05-07 00:00:001) ACCESS ROAD FOR FIRE AND PARAMEDICAL
 EQUIPMENT ARE TO BE AT LEAST TWENTY
 FEET IN CLEAR WIDTH.
  
 2) SECURITY GATES REQUIRE SEPARATE PLAN
 AND PERMITS. THE SECURITY GATES ARE
 TO BE AT LEAST TWENTY FEET IN CLEAR
 WIDTH. PROVISIONS ARE TO BE MADE FOR
 FIRE AND PARAMEDICAL EQUIPMENT. IF
 ELECTRIC, PROVISIONS ARE TO BE MADE
 FOR ACCESS IN THE EVENT OF LOSS OF
 POWER.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910