Plan Review Details - Permit 02031298
| Plan Review Stops For Permit 02031298 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-06-11 |
Time |
11:49 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-04-18 |
Time |
10:16 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-04-18 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2002-04-18 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 02031298 | | | 4310 SAN MARINO BLVD | | | CONT: ALLIANCE | | | TEL: (561) 242-5613 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1)- RESIDENT INSPECTOR PROGRAM, 3 SETS | | | OF PLANS REQUIRED, LANDSCAPE DRAWINGS | | | ONLY 2 COPIES REQUIRE A THIRD APPROVED | | | PLAN. | | | 2)- FL BLD CODE 1606.1.7 INFORMATION | | | MISSING RELATED TO WIND, SEE NEW CODE!!! | | | 3)- FL BLD CODE 1606.1.4 PROTECTION OF | | | OPENINGS, PRODUCT APPROVALS (3 SETS) | | | FOR ALL GLAZED OPENINGS,EITHER | | | STORM SHUTTERS OR LARGE MISSLE | | | IMPACT GLAZING, SBCCI OR DADE REPORT! | | | 4)- FLBLD CODE 1707.5 CONCRETE ROOF TILE | | | REQUIRES (3) PRODUCT APPROVAL FOR | | | WIND ZONE. | | | 5)- FL BLD CODE 1804.1.3 THE BOTTOM OF | | | THE FOUNDATION SHALL BE NO LESS THAN 12" | | | BELOW FINISH GRADE. | | | 6)- SHEET AM-2 INDICATES SEMCO STRAPS, | | | NO LONGER IN BUSINESS! | | | 7)- CONTRACTOR TO SUBMIT PLANS TO P. B. | | | COUNTY FOR IMPACT FEE ASSESSMENT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-14 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-14 |
Time |
18:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-25 |
Time |
06:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-25 |
Time |
06:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-03-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-21 |
Time |
08:40 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-05-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-07 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-07 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2002-05-07 00:00:00 | 1) ACCESS ROAD FOR FIRE AND PARAMEDICAL | | | EQUIPMENT ARE TO BE AT LEAST TWENTY | | | FEET IN CLEAR WIDTH. | | | | | | 2) SECURITY GATES REQUIRE SEPARATE PLAN | | | AND PERMITS. THE SECURITY GATES ARE | | | TO BE AT LEAST TWENTY FEET IN CLEAR | | | WIDTH. PROVISIONS ARE TO BE MADE FOR | | | FIRE AND PARAMEDICAL EQUIPMENT. IF | | | ELECTRIC, PROVISIONS ARE TO BE MADE | | | FOR ACCESS IN THE EVENT OF LOSS OF | | | POWER. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
|