Plan Review Details - Permit 02031221
Plan Review Stops For Permit 02031221
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-06-20 Cont ID  
Sent By hpiskura Date 2002-06-20 Time 13:45 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-06-20 00:00:00PROVISO: PERMITTED FOR GARAGE AND
 STORAGE SHED USE ONLY.CODE
 REQUIREMENTS AND IMPACT FEES FOR GARAGE
 APARTMENT ARE NOT MET AT THIS TIME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-06-11 Cont ID  
Sent By pkrauss Date 2002-05-28 Time 11:37 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-06-11 00:00:00BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, THE PERMIT PLANS STAMPED
 BY THAT OFFICE AND A COPY OF THE PAID
 RECEIPT ATTACHED TO THE PERMIT
 APPLICATION.CALL 561-233-5025 FOR
 MORE INFORMATION.
  
 SHEET A3, PLEASE PROVIDE A DETAIL FOR
 THE CONNECTION OF THE 2X12 RAFTERS TO
 THE EXISTING SHED WALL.ALSO INDICATE
 A CONTINUOUS LOADPATH FOR THE UPLIFT
 CONNECTION IN THE EXISTING WALL OR
 PROVIDE NEW.
  
 THE FLOOR PLAN SHOWS SEVERAL OPENINGS
 INTO THE GARAGE.FBC 411.2.8.
  
 THE WIND SPEED FOR WEST PALM BEACH IS
 140 MPH, NOT THE 120 MPH DECLARED.SEE
 FBC 1606.1.6 AS AMENDED BY THE CITY.
  
 SHOW OR NOTE THE ROOF COVERING TO BE
 USED THE PITCH AND THE WIND PRESSURES
 +/-
  
 SHOW A FRAMING DETAIL FOR THE PARAPET
 TOBE CONSTRUCTED ON THE EXISTING
 BUILDING.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-05-15 Cont ID  
Sent By btrobaug Date 2002-05-15 Time 12:43 Rev Time 0.00
Received By btrobaug Date 2002-05-15 Time 12:34 Sent To P
Notes
2002-05-15 00:00:00SEPERATE ELECTRICAL PERMIT
 REQUIRED.PLEASE SUBMIT PLANS FOR REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-05-28 Cont ID  
Sent By kstevens Date 2002-05-16 Time 10:09 Rev Time 0.25
Received By pkrauss Date 2002-05-28 Time 11:35 Sent To B
Notes
2002-05-28 00:00:00NO MECHANICAL SUBMITTED FOR REVIEW.

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-05-16 Cont ID  
Sent By btrobaug Date 2002-05-15 Time 12:50 Rev Time 0.00
Received By kstevens Date 2002-05-16 Time 10:08 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2002-05-14 Cont ID  
Sent By sgraham Date 2002-05-14 Time 14:57 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2002-03-20 Cont ID  
Sent By sgraham Date 2002-03-20 Time 09:22 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-03-20 00:00:00CLASS B EXPIRED