Plan Review Details - Permit 02031221
| Plan Review Stops For Permit 02031221 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-06-20 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-06-20 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-20 00:00:00 | PROVISO: PERMITTED FOR GARAGE AND | | | STORAGE SHED USE ONLY.CODE | | | REQUIREMENTS AND IMPACT FEES FOR GARAGE | | | APARTMENT ARE NOT MET AT THIS TIME. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-28 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-11 00:00:00 | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | SHEET A3, PLEASE PROVIDE A DETAIL FOR | | | THE CONNECTION OF THE 2X12 RAFTERS TO | | | THE EXISTING SHED WALL.ALSO INDICATE | | | A CONTINUOUS LOADPATH FOR THE UPLIFT | | | CONNECTION IN THE EXISTING WALL OR | | | PROVIDE NEW. | | | | | | THE FLOOR PLAN SHOWS SEVERAL OPENINGS | | | INTO THE GARAGE.FBC 411.2.8. | | | | | | THE WIND SPEED FOR WEST PALM BEACH IS | | | 140 MPH, NOT THE 120 MPH DECLARED.SEE | | | FBC 1606.1.6 AS AMENDED BY THE CITY. | | | | | | SHOW OR NOTE THE ROOF COVERING TO BE | | | USED THE PITCH AND THE WIND PRESSURES | | | +/- | | | | | | SHOW A FRAMING DETAIL FOR THE PARAPET | | | TOBE CONSTRUCTED ON THE EXISTING | | | BUILDING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2002-05-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-15 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-15 |
Time |
12:34 |
Sent To |
P |
|
| Notes |
| 2002-05-15 00:00:00 | SEPERATE ELECTRICAL PERMIT | | | REQUIRED.PLEASE SUBMIT PLANS FOR REVIEW. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-16 |
Time |
10:09 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-05-28 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2002-05-28 00:00:00 | NO MECHANICAL SUBMITTED FOR REVIEW. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-05-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-15 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-16 |
Time |
10:08 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-05-14 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-05-14 |
Time |
14:57 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-03-20 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-20 |
Time |
09:22 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-20 00:00:00 | CLASS B EXPIRED |
|
|
|