Plan Review Details - Permit 02031182
Plan Review Stops For Permit 02031182
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-17 Cont ID  
Sent By hpiskura Date 2002-05-17 Time 08:44 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-04-09 Cont ID  
Sent By hpiskura Date 2002-04-09 Time 11:36 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-06 Cont ID  
Sent By dpalmer Date 2002-05-06 Time 06:28 Rev Time 0.00
Received By dpalmer Date 2002-05-06 Time 06:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-02 Cont ID  
Sent By dpalmer Date 2002-04-02 Time 06:57 Rev Time 0.00
Received By dpalmer Date 2002-04-02 Time 06:57 Sent To  
Notes
2002-04-02 00:00:00***************** UNSAT ***************
  
 1)NOTE:PLEASE CLARIFY LOAD ON EXISTING
 SERVICE. SERVICE IS SHOWN AS 600A WITH
 A NEWLOAD OF 143AMPS BEING ADDED.
  
 2)NOTE: PLEASE NOTE THAT PANEL IS SHOWN
 AS BEING RATED FOR 150A`S WITH A 200A
 FEED. PLEASE CORRELATE.
  
 3)NOTE: PLEASE NOTE MISSING SHOW WINDOW
 OUTLET PER 210-62. PLEASE NOTE 12` OR
 PORTIONS OF WINDOWS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 EELCTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-05-17 Cont ID  
Sent By mcarsill Date 2002-05-17 Time 08:49 Rev Time 0.00
Received By mcarsill Date 2002-05-17 Time 08:49 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-03-28 Cont ID  
Sent By mcarsill Date 2002-03-28 Time 14:31 Rev Time 0.00
Received By mcarsill Date 2002-03-28 Time 14:31 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-09 Cont ID  
Sent By ndenmark Date 2002-05-09 Time 12:53 Rev Time 0.25
Received By ndenmark Date 2002-05-09 Time 12:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-04-08 Cont ID  
Sent By ndenmark Date 2002-04-08 Time 12:48 Rev Time 0.25
Received By ndenmark Date 2002-04-08 Time 12:48 Sent To  
Notes
2002-04-08 00:00:00PROVISO:
 FBC 1511.17 REQUIRES MINIMUM 8" FOR
 CURB

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-17 Cont ID  
Sent By kstevens Date 2002-05-17 Time 08:43 Rev Time 0.00
Received By kstevens Date 2002-05-17 Time 08:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-04-20 Cont ID  
Sent By kstevens Date 2002-04-20 Time 17:22 Rev Time 0.00
Received By kstevens Date 2002-04-20 Time 17:22 Sent To  
Notes
2002-04-20 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11 - FACBC
  
 1) PER FBC PLUMBING TABLE 403.1 ONE
 SERVICE SINK IS REQUIRED.
 2) WATER COOLER SHALL CONFORM TO ARI -
 1010. PLEASE SUBMIT MANUFACTURE INFORM-
 ATION SHOWING COMPLIANCE.
 3) LOUNGE SINK SHALL CONFORM TO FACBC -
 SECTION 4.24. PLEASE PROVIDE DETAIL.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377