| Plan Review Stops For Permit 02031079 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-09-03 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-03 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-09-03 |
Time |
08:31 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-08-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-08-21 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-21 00:00:00 | THE VARCO-PRUDEN PLANS ARE REFERENCED TO | | | THE "IBC" CODE AND A 120 MPH WIND | | | SPEED. | | | | | | A PORTION OF THE V-P CALCULATIONS | | | IDENTIFIED AS "BUILDING 1" CITE 120 MPH. | | | | | | THE CITY IS UNDER THE 2001 FLORIDA | | | BUILDING CODE, (FBC) AND WHOLLY WITHIN | | | A 140MPH WIND ZONE.THE PLANS MUST | | | REFLECT WIND DESIGN TO EITHER FBC 1606 | | | OR ASCE 7-98.PLEASE REVISE AS | | | NECESSARY WITH THE ENGINEER OF RECORD | | | HAVING REVIEWED THE V-P PLANS FOR | | | CONFIRMATION WITH DESIGN INTENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-06-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-06-18 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-18 00:00:00 | COMMENTS ON 4/18/02 CHECKLIST ARE NOT | | | ADDRESSED. | | | | | | PLEASE REVIEW THE 2001 FLORIDA BUILDING | | | CODE.PROVIDE THE INFORMATION | | | ENUMERATED IN FBC 104.3.1.1 AND | | | 1606.1.7 IN THE FORM OF PLANS, NOTES OR | | | SPECIFICATIONS AS NECESSARY. | | | | | | IF THE EVALUATION OR TEST REPORTS FOR | | | THE DOORS WINDOWS AND ROOF COVERING ARE | | | NOT INCLUDED WITH THE PERMIT | | | APPLICTION, ASEPARATE PERMIT AND | | | ADDITIONAL FEES WILL BE NECESSARY. | | | | | | PLEASE REMOVE AND INSERT PAGES AS | | | NECESSARY TO HAVE TWO CLEAR, CONCISE | | | SETS OF PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-04-18 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-18 00:00:00 | | | | | | | THIS BUILDING WILL BE LOCATED IN AN A8 | | | FLOOD ZONE WITH A BFE OF 16.0'. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE, AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. | | | | | | THE CONSTRUCTION WILL BE SUBJECT TO THE | | | 2001 FLORIDA BUILDING CODE.THE DESIGN | | | INFORMATION CALLED OUT ON THE PLANS IS | | | NOT VALID.THE CITY OF WEST PALM BEACH | | | IS LOCATED IN A 140 MPH WIND ZONE. | | | | | | MINIMUM PLAN REVIEW CRITERIA IS | | | CONTAINED IN SECTIONS FBC 104 AND | | | 1606.1.7 OF THE CODE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-08-16 |
Time |
06:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-08-16 |
Time |
06:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-21 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-21 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2002-06-21 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE PLANS NEED TO PUT | | | INTO TWO COMPLETE SETS FOR REVIEW. | | | PLEASE TAKE OUT OLD SHEETS AND INSERT | | | NEW SHEETS. PUT OLD/VOIDED SHEETS IN | | | ONE SET ONLY. | | | PLEASE NOTE NEW SHEETS NOT PUT INTO | | | SETS???? | | | | | | 2)NOTE: PLEASE NOTE SAME COMMENTS AS | | | FIRST REVIEW FOR MDP. PLEASE NOTE STILL | | | SHOWS AS "MLO" WITH 8 3-POLE SPACES?? | | | 230-71A | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-01 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-01 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2002-04-01 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT "MDP" SHOWS | | | SIX MAINS AND SPACES FOR TWO MORE. | | | PLEASE NOTE THAT MDP IS BEING SHOWN AS | | | "MLO". 230-71A. | | | | | | 2)NOTE: PLEASE NOTE, LOAD CALCULATIONS | | | NEED TO BE SHOWN. PLEASE SHOW W-PER SQ | | | FT./ REC LOADS/ ETC. | | | 220-3,220-10,220-11,220-13 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. PLEASE SEE ANY FIRE REVIEW | | | COMMENTS THAT MAY AFFECT ELECTRICAL | | | SHEETS. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICALPLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
N |
Date |
2002-07-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-07-23 |
Time |
11:34 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-07-23 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2002-07-23 00:00:00 | N/A: | | | 1. SEE PERMIT # 02071300 FOR CIVIL /SITE | | | WORK REVIEW AND PERMITTING. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2002-06-21 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-06-21 |
Time |
11:28 |
Rev Time |
5.00 |
| Received By |
mamini |
Date |
2002-06-21 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2002-06-21 00:00:00 | FAILED : | | | 1. PLEASE PROVIDE A COPY OF THE NORTHERN | | | PALM BEACH COUNTY IMPROVEMENT DIST. | | | PERMIT. | | | 2. A SEPARATE PERMIT AND FEES FOR THE | | | CIVIL/SITE WORKS IS REQUIRED. | | | 3. ITEMS INDICATED ABOVE WERE NOT | | | ADDRESSED IN YOUR RESPONSES TO OUR | | | PREVIOUS REVIEW COMMENTS. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-03-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-19 |
Time |
10:00 |
Rev Time |
3.00 |
| Received By |
mamini |
Date |
2002-03-19 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2002-03-19 00:00:00 | FAILED: | | | 1. DRIVEWAY APPROACHES MUST BE | | | CONSTRUCTED PER FDOT STANDARD, INDEX NO. | | | 515, PLEASE INDICATE. | | | 2. ALL OFF-STREET PARKING MUST BE | | | PAINTED WITH DOUBLE 4" WHITE FOR REGULAR | | | AND BLUE FOR H.C., PLEASE REVISE THE | | | DETAILS AS SHOWN ON SHEET C3. | | | 3. ALL BACKFLOW PREVENTERS MUST BE | | | INSPECTED AND APPROVED BY THE CITY, | | | 659-8005 EXT. 2008 ORVILLE POLK. | | | 4. PLEASE SHOW THE REQUIRED CLEARANCES | | | AT ALL CONFLICTS. | | | 5. WATER AND SEWER SERVICES AS SHOWN | | | ON CIVIL PLAN DO NOT MATCHED THE | | | PLUMBING PLANS.OIL/WATER SEPARATOR | | | AND ITS LOCATION MUST BE SHOWN ON CIVIL. | | | A SAND INTERCEPTOR MUST BE PROVIDED IF | | | HEAVY MACHINERY AND EQUIPMENT ARE BEING | | | WASHED.ALL INTERCEPTORS MUST BE | | | INSPECTED AND APPROVED BY THE CITY, | | | 837-4051 EXT. 4074 RODNEY COMPO. | | | 6. PLEASE PROVIDE STORM WATER CALC. | | | FOR OUR REVIEW AND APPROVAL. | | | 7. A SEPARATE PERMIT FROM NORTHERN PALM | | | BEACH COUNTY IMPROVEMENT DISTRICT WILL | | | BE REQUIRED, PLEASE SUBMIT A COPY. | | | 8. PLEASE SHOW INVERT ELEV. AND END WALL | | | FOR 18" RCP ON NORTHSIDE OF THE | | | RETETION POND. | | | 9. IS THERE ANY DUMPSTER ENCLOSURE | | | PROPOSED FOR THE SITE? PLEASE NOTE THAT | | | IT SHOULD BE CONSTRUCTED PER CITY | | | STANDARD AND REQUIREMENT, IF GARBAGE IS | | | TO BE PICKED UP BY THE CITY. | | | 10. A SEPARATE PERMIT AND FEES FOR THE | | | SITE/CIVIL WORKS WILL BE REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2002-09-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-09-06 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-09-06 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2002-08-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-09-03 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-08-13 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2002-08-13 00:00:00 | 1) THE FIRE HYDRANTS SHOWN ON THE SITE | | | PLAN ARE LOCATED BEHIND A CHAIN-LINK | | | FENCE AND PROVIDES NO PROTECTION FOR | | | THE TOOL EQUIPMENT RENTAL. | | | | | | 2) NO DETAILS PROVIDED FOR THE PROPOSED | | | LP GAS TANK SHOWN ON THE SITE PLAN. NO | | | BARRIER PROTECTION SHOWN FOR THE LG | | | GAS TANK OR PROPOSED 3000 GALLON FUEL | | | TANK. SEPARATE PLANS AND PERMITS | | | REQUIRED. | | | | | | 3) GAS METER NOTED NEAR WELDING AREA. | | | | | | 4) PLEASE ENSURE THAT ELECTRICAL | | | DRAWINGS MATCH THE ARCHITECTURAL | | | DRAWINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2002-06-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-24 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-06-28 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2002-06-28 00:00:00 | PLEASE RESPOND TO PREVIOUS COMMENTS | | | PROVIDED BY THIS OFFICE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-04-03 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-04-03 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-04-03 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2002-04-03 00:00:00 | A) FIRE HYDRANTS ARE TO BE PROVIDED ON | | | THE PROPERTY. NO FIRE HYDRANTS ARE | | | SHOWN ON THE SITE PLAN. | | | B) HOW DOES FIRE AND PARAMEDICAL | | | EQUIPMENT ACCESS THE PROPERTY WHEN THE | | | SLIDING GATES ARE CLOSED. WHAT | | | PROVISIONS WILL BE MADE. | | | C) BUILDING ADDRESS REQUIRED. | | | D) MORE DETAILS REQUIRED ON LP GAS | | | STORAGE AND AND ABOVE GROUND FUEL TANK | | | SHOWN ON SITE PLAN. | | | E) SEPARATE PLAN AND PERMITS REQUIRED | | | ON SPRAY BOOTH AND EXTINGUISHING SYSTEM. | | | F) PLEASE INDICATE WHAT BUILDING AND | | | FIRE CODES THE BUILDING WAS DESIGNED | | | TO. | | | G) PLEASE INDICATE OCCUPANT LOADS FOR | | | THE BUILDING. | | | H) THE PAINT SPRAY BOOTH MUST HAVE AT | | | LEAST THREE FEET ON ALL SIDES OF IT | | | TO PROVIDE CLEANING CAPABILITIES. | | | I) ARE ALL EXIT SIGNS SHOWN ON THE | | | LIGHTING FLOOR PLAN. | | | J) PLEASE PROVIDE MORE DETAILS ON WELDER | | | 50A. | | | K) PLEASE INDICATE ALL FIRE EXTINGUISHER | | | LOCATIONS. | | | L) PLEASE EXPLAIN EXITING RATIONALE FROM | | | DISPLAY AREA 101. IT APPEARS THAT | | | EXITING ENTERS INTO A MORE HAZARDOUS | | | AREA. | | | M) THE PLANS INDICATE THAT THE BUILDING | | | WILL BE CLASSIFIED AS BUSINESS. THE | | | LIFE SAFETY CODE DEFINES BUSINESS AS | | | "AS ONE USED FOR ACCOUNT AND RECORD | | | KEEPING PURPOSES OR THE TRANSACTION | | | OF BUSINESS OTHER THAN MERCANTILE" THIS | | | OFFICE DOES NOT APPEAR TO BE CORRECTLY | | | CATEGORIZED. | | | N) PLEASE INDICATE USES FOR WAREHOUSE 1, | | | PUMP AND POWER STORAGE, AND DISPLAY. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-06 |
Time |
09:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-11-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-15 |
Time |
16:03 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-11-15 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2002-11-15 00:00:00 | CALLED CONTRACTOR - NEEDS TO COMPLETE A | | | PERMIT APPLICATION FOR SPRAY BOOTH. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-08-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-06 |
Time |
09:34 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-08-15 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2002-08-15 00:00:00 | PROVISO: | | | | | | SEPARATE PERMITS REQUIRED FOR PAINT | | | SPRAY BOOTH, GENERATOR & FUEL TANK, & | | | GAS.PLEASE PROVIDE PLANS WITH PERMIT | | | APPLICATION. | | | | | | PERMITS FOR ABOVE WORK REQUIRED PRIOR | | | TO WORK COMMENCING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-06-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-24 |
Time |
08:11 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-06-24 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2002-06-24 00:00:00 | PROVISO COMMENTS BY NANCY DENMARK | | | DATED 4/4/02: | | | | | | AIR BALANCE SCHEDULE PER 2001 FBC(M) | | | 601.4 SHALL BE REQUIRED. | | | | | | SEPARATE PERMITS & PLANS REQUIRED FOR | | | PAINT SPRAY BOOTH, FUEL (FOR GENERATOR) | | | & FOR GENERATOR. | | | | | | PERMITS FOR ABOVE WORK REQUIRED PRIOR | | | TO WORK COMMENCING ON ANY OF THE | | | AFORMENTIONED ITEMS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT NANCY DENMARK (CHIEF MECH | | | INSPECTOR) (561) 659-8096 EXT 8221 OR | | | PATTY KRAUSS (MECH PLAN REVIEW) EXT | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-04-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2002-04-04 |
Time |
11:04 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2002-04-04 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2002-04-04 00:00:00 | PROVISO: | | | | | | AIR BALANCE PER 2001 FBC(M) 601.4 SHALL | | | BE REQUIRED. | | | SEPARATE PERMITS AND PLANS REQUIRED FOR | | | PAINT SPRAY BOOTH, SUPPRESSION SYSTEM | | | FOR PAINT SPRAY BOOTH, FUEL (FOR | | | GENERATOR) AND FOR GENERATOR. | | | PERMITS FOR ABOVE WORK REQUIRED PRIOR TO | | | WORK COMMENCING ON ITEMS. | | | | | | ANY QUESTIONS PLEASE CAL: | | | NANCY DENMARK, | | | CHIEF MECHANICAL INSPECTOR | | | (561) 659-8096 EXT. 8221 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-10 |
Time |
10:27 |
Rev Time |
0.20 |
| Received By |
kstevens |
Date |
2003-01-10 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2003-01-10 00:00:00 | SUBMITTAL APPROVED (12-18-02) - RETURNED | | | TO GAS CONTRACTOR - APPROVAL FOR GAS | | | APPLIANCE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-10-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-31 |
Time |
13:21 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-10-31 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2002-10-31 00:00:00 | SUBMITTAL OK - GREASE TRAP DRAWING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-08-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-08-17 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-08-17 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2002-08-17 00:00:00 | PASSED - NO GAS REVIEW,INFORMATION | | | REQUIRED AT TIME OF GAS PERMIT APPLICAT- | | | ION. SEPARATE PERMIT REQUIRED FOR GAS. | | | A) NEED MANUFACTURE SHEETS FOR GAS EQUIP | | | B) SHOW LOCATION AND CAPACITY OF L-P | | | TANK (SEE PREVIOUS REVIEW (D)) | | | C) UNDERGROUND OR ABOVE GROUND TANK?? | | | (SEE PREVIOUS REVIEW (E)) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-06-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-25 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-25 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2002-06-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | | | | 1) FROM PREVIOUS REVIEW: DIMENTIONS FOR | | | TOILET ROOMS NOT SHOWN. MINIMUM TOILET | | | SIZE FOR TOILET ROOMS WITH DOOR IN FRONT | | | IS 7'5" X 5'3". 5' TURNING RADIUS SHALL | | | NOT INCLUDE SPACE OCCUPIED BY THE WATER | | | CLOSET. | | | 2) FROM PREVIOUS REVIEW: WATER CLOSETS | | | SHALL BE LOCATED 1'6" OFF THE WALL TO | | | THE CENTER OF FIXTURE. | | | 3) ALL GAS INFORMATION REQUESTED SHALL | | | BE SUBMITTED AT TIME OF GAS PERMIT | | | APPLICATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-04-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-04-19 |
Time |
19:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-04-19 |
Time |
19:35 |
Sent To |
|
|
| Notes |
| 2002-04-19 00:00:00 | DENIED | | | REFERENCE: FBC-2002 PLUMBING - FACBC-97 | | | FBC-2001 FUEL GAS - NFPA-58 | | | | | | 1) SHT A-1 PLEASE SUBMIT TOILET ROOM | | | DETAILS. SHOW COMPLIANCE WITH FACBC SEC | | | 4.16 AND SEC 4.19 AND ALL SUBSECTIONS. | | | PLEASE SUBMIT IN A 1/8" OR 1/4" SCALE, | | | SHOW W/C'S TO BE 1'6" OFF WALL TO CENTER | | | 2) SHT A-1 PLEASE SHOW COMPLIANCE WITH | | | FACBC SEC 4.15.2, AND SEC 4.1.3(10) FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | 3) SHT P-1, WILL THE EYEWASH ALSO HAVE | | | AN EMEMRGENCY SHOWER? | | | 4) SHTS P-2/P-3 FUNNEL FLOOR DRAIN NOT | | | APPROVED. ALL INDIRECT WASTE AND DRIPS | | | SHALL DRAIN INTO A FLOOR SINK. 802.2 & | | | 802.3 | | | 5) SHT P-3 SANITARY RISER DIAGRAM, 2-WAY | | | CLEAN OUTS ARE REQUIRED ON PIPES ENTER- | | | ING AND EXITING THE GREASE TRAP. SEE | | | ATTACHED SHEET FOR APPROVED GREASE TRAP | | | DETAIL. | | | 6) SHT P-3 GEN PLMG NOTES #1 NFPA 58 IS | | | FOR L.P. GAS NOT NFPA 54. #3 SIZE TO BE | | | BASED ON FBC-2001 FUEL GAS TABLE APPROI- | | | ATE FOR LP AND INDICATED PRESSURE. | | | 7) GREASE TRAP TO BE SIZED BY RODNEY | | | COMPO ENVIRONMENTAL COMPLIANCE PER UTIL- | | | ITY ORD #2938-96. PLEASE CALL (561)- | | | 837-4074. | | | 8) SHT P-4 WATER HEATER DETAIL, DIELECT- | | | RIC UNIONS NOT APPROVED. | | | 9) SEPARATE GAS PERMIT REQUIRED. FOLLOW- | | | ING IS LIST OF GAS PERMIT APPLICATION | | | REQUIREMENTS NEEDED FOR PERMIT. | | | A. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 GAS CODE SEC. 402.4. | | | B. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2001 FUEL GAG CODE | | | 501.13 AND 501.14 | | | C. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND FBC-2001 | | | FUEL GAS CODE CHAPTER 6. | | | D. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | E. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | 10) SHT C1 INDICATES A LP GAS TANK IN | | | THE S.W. CORNER, AND SHT P-2 SHOWS LP | | | TANKS NEAR THE S.E END OF THE BLDG. | | | PLEASE CLAIRFY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-09-09 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-08-07 |
Time |
07:52 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-07 00:00:00 | ZONING HAS ISSUE WITH THE FENCE, MATTER | | | WILL BE DECIDED AT A LATER DATE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-06-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-06-05 |
Time |
09:26 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-05 00:00:00 | DENIED BY ZONING, EQUIP DISPLAY AREA | | | MUST BE OF WASHED OR SIFTED ROCK NOT | | | CRUSHED CONCRETE AS PER ENG DEPT . | | | FENCE MUST BE CONCRETE WALL OR WOOD | | | CONSTRUCTION |
|
|