Plan Review Details - Permit 02030819
Plan Review Stops For Permit 02030819
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-04-15 Cont ID  
Sent By dpalmer Date 2002-04-04 Time 15:54 Rev Time 0.75
Received By mmclean Date   Time   Sent To  
Notes
2002-04-18 00:00:00LEA SMITH OK TO ISSUE PERMIT MM

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-21 Cont ID  
Sent By dpalmer Date 2002-05-21 Time 09:10 Rev Time 0.00
Received By dpalmer Date 2002-05-21 Time 09:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-04-04 Cont ID  
Sent By kstevens Date 2002-04-04 Time 09:44 Rev Time 0.00
Received By dpalmer Date 2002-04-04 Time 15:52 Sent To B
Notes
2002-04-04 00:00:00************ NOTE*****************
  
 1)NOTE: PLEASE NOTE THAT ELECTRICAL
 WAS OK, BUT DUE TO MANY PLUMB COMMENTS,
 THERE WILL BE CHANGES MADE TO SHEET
 AND ELECTRICAL WILL BE STAMPED WHEN RE-
 SUBMITTED AND PASSED BY PLUMB.
  
 PLEASE ADDRESS PLUMB COMMENTS AND SUBMIT
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-21 Cont ID  
Sent By kstevens Date 2002-05-21 Time 09:27 Rev Time 0.00
Received By kstevens Date 2002-05-21 Time 09:27 Sent To  
Notes
2002-05-21 00:00:00PASSED/PROVISO
  
 EXTERNAL HARTFORD LOOP REQUIRED - NO IN-
 TERNAL POSITIVE RETENTION SHOWN ON HEAT-
 ER SUBMITTAL.
 PASSED/PROVISO
  
 EXTERNAL HARTFORD LOOP REQUIRED - NO IN-
 TERNAL POSITIVE RETENTION SHOWN ON HEAT-
 ER SUBMITTAL.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-29 Cont ID  
Sent By kstevens Date 2002-03-29 Time 16:31 Rev Time 0.00
Received By kstevens Date 2002-03-29 Time 16:30 Sent To E
Notes
2002-03-29 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) FBC-2001 SEC 424.2.6.6.2 PLEASE GIVE
 MANUFACTURE AND MODEL # FOR SELF CLOSING
 SAFTY COVER ON VACUUM LINE.
 2)
 FBC-2001 SEC 424.2.6.4 SUBMIT MANUFACT-
 URES RECOMMENDATIONS.
 3)
 FBC-2001 SEC 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4)
 FBC-2001 SEC 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5)
 FBC-2001 SEC 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 6)
 FBC-2001 SEC 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 7)
 FBC-2001 SEC 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 8)
 FBC-2001 SEC 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 9)
 FBC-2001 SEC 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-03-18 Cont ID  
Sent By sgraham Date 2002-03-18 Time 09:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***