| Plan Review Stops For Permit 02030779 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-11-18 |
Time |
08:53 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-18 00:00:00 | OK PER B COMPTON PREINSPECTION 11/18/02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-09-17 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-09-17 00:00:00 | **********FAILED************** | | | | | | 1. NEED ELEVATIONS SHOWN ON SURVEY/PLOT | | | PLAN SHOWINGFFE OF HOUSE & CARPORT. | | | FFE MUST BE THE SAME. | | | 2. NEED STORM PANELS ADDED TO PERMIT | | | FOR ALL WINDOWS & DOORS INSTALLED. NEED | | | 2 COPIES OF PRODUCT APPROVALS FOR PANELS | | | 3. NEED PRODUCT APPROVALS FOR ROOFING | | | MATERIALS. | | | 4. PLANS NEED TO SHOW DETAILS OF | | | ALL WORK COMPLETED:IE: PLUMBING, ELEC | | | MECHANICAL, ROOFING ACCORDING TO FBC2001 | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 659-8096 EXT. 8394 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2002-09-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-17 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
| 2002-09-17 00:00:00 | THERE ARE NO ELECTRICAL PLANS FOR | | | REVIEW. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096.EXT 8392 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-11-18 |
Time |
08:28 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-11-18 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2002-11-18 00:00:00 | TWO DROPS ADDED TOEXISTING SYSTEM - | | | PER BOBBY COMPTON |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-09-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-09-26 |
Time |
18:39 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-09-26 |
Time |
19:09 |
Sent To |
|
|
| Notes |
| 2002-09-26 00:00:00 | THERE ARE NO MECHANICAL PLANS,ENERGY | | | CALCULATIONS,MANUAL (J) TO REVIEW | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-10-28 |
Time |
08:31 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-10-28 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-17 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-09-26 |
Time |
18:27 |
Sent To |
M |
|
| Notes |
| 2002-09-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) BATHROOM IN NOT WIDE ENOUGH. 30" IS | | | REQUIRED FOR TUB, 30" REQUIRED FOR TOI- | | | LET, AND LAV REQUIRED IN BATHROOM WHICH | | | WILL NEED MINIMUM 19" LAV WITH 18" | | | CLEARANCE IN FRONT. BATH ROOM SHOWS 3'6" | | | LAV. SINK NOT SHOWN ON PLANS | | | 2) PLEASE SUBMIT A SANITARY RISER DIA- | | | GRAM. | | | 3) PLEASE SHOW ALL DIMENTIONS FOR ROOMS. | | | 4) TWO COPIES OF PLANS REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-11-18 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2002-11-18 |
Time |
09:06 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-11-18 00:00:00 | PER SG 11/18/02 LS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-03-18 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-18 |
Time |
16:21 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-18 00:00:00 | NEED SURVEY |
|
|