Plan Review Details - Permit 02030779
Plan Review Stops For Permit 02030779
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-11-18 Cont ID  
Sent By lsmith Date 2002-11-18 Time 08:53 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-11-18 00:00:00OK PER B COMPTON PREINSPECTION 11/18/02

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-09-17 Cont ID  
Sent By lsmith Date 2002-09-17 Time 09:20 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
2002-09-17 00:00:00**********FAILED**************
  
 1. NEED ELEVATIONS SHOWN ON SURVEY/PLOT
 PLAN SHOWINGFFE OF HOUSE & CARPORT.
 FFE MUST BE THE SAME.
 2. NEED STORM PANELS ADDED TO PERMIT
 FOR ALL WINDOWS & DOORS INSTALLED. NEED
 2 COPIES OF PRODUCT APPROVALS FOR PANELS
 3. NEED PRODUCT APPROVALS FOR ROOFING
 MATERIALS.
 4. PLANS NEED TO SHOW DETAILS OF
 ALL WORK COMPLETED:IE: PLUMBING, ELEC
 MECHANICAL, ROOFING ACCORDING TO FBC2001
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-09-17 Cont ID  
Sent By btrobaug Date 2002-09-17 Time 12:54 Rev Time 0.00
Received By btrobaug Date   Time   Sent To P
Notes
2002-09-17 00:00:00THERE ARE NO ELECTRICAL PLANS FOR
 REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096.EXT 8392

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-11-18 Cont ID  
Sent By pkrauss Date 2002-11-18 Time 08:28 Rev Time 0.25
Received By pkrauss Date 2002-11-18 Time 08:28 Sent To  
Notes
2002-11-18 00:00:00TWO DROPS ADDED TOEXISTING SYSTEM -
 PER BOBBY COMPTON

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-09-26 Cont ID  
Sent By kstevens Date 2002-09-26 Time 18:39 Rev Time 0.33
Received By hmoser Date 2002-09-26 Time 19:09 Sent To  
Notes
2002-09-26 00:00:00THERE ARE NO MECHANICAL PLANS,ENERGY
 CALCULATIONS,MANUAL (J) TO REVIEW
 PLAN REVIEW BY HAROLD MOSER
 (561)659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-10-28 Cont ID  
Sent By kstevens Date 2002-10-28 Time 08:31 Rev Time 0.50
Received By kstevens Date 2002-10-28 Time 08:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-09-26 Cont ID  
Sent By btrobaug Date 2002-09-17 Time 12:55 Rev Time 0.00
Received By kstevens Date 2002-09-26 Time 18:27 Sent To M
Notes
2002-09-26 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) BATHROOM IN NOT WIDE ENOUGH. 30" IS
 REQUIRED FOR TUB, 30" REQUIRED FOR TOI-
 LET, AND LAV REQUIRED IN BATHROOM WHICH
 WILL NEED MINIMUM 19" LAV WITH 18"
 CLEARANCE IN FRONT. BATH ROOM SHOWS 3'6"
 LAV. SINK NOT SHOWN ON PLANS
 2) PLEASE SUBMIT A SANITARY RISER DIA-
 GRAM.
 3) PLEASE SHOW ALL DIMENTIONS FOR ROOMS.
 4) TWO COPIES OF PLANS REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2002-11-18 Cont ID  
Sent By lsmith Date 2002-11-18 Time 09:06 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
2002-11-18 00:00:00PER SG 11/18/02 LS

Review Stop Z ZONING
Rev No 1 Status F Date 2002-03-18 Cont ID  
Sent By sgraham Date 2002-03-18 Time 16:21 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2002-03-18 00:00:00NEED SURVEY