Plan Review Details - Permit 02030113
Plan Review Stops For Permit 02030113
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-05-16 Cont ID  
Sent By jwitmer Date 2002-05-16 Time 14:06 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-16 00:00:00PROVISO SAME AS 4/29/02 SAME NOTE WELD
 WIRE TO BE SUPPORTED @ 3' OR MANUFAC.
 SPECS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-04-29 Cont ID  
Sent By jwitmer Date 2002-04-29 Time 10:29 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-04-29 00:00:00*******BUILDING PROVISO*********
 PERMIT # 02030113
 9434 LANTERN BAY CIR.
 1)- FL BLDG 1909.3 (EXEPTION# 2)
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4XW1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO THE
 UPPER 1/3RD OF THE SLAB SHALL BE SUP-
 PORTED BY APPROVED MATERIALS OR SUPPORTS
 AT SPACING NOT TO EXCEED 3 FT OR IN
 ACCORDANCE WITH MANUFACTURER'S SPEC.
 ANY QUESTIONS PLEASE CALL,
 JIM WITMER
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-10 Cont ID  
Sent By jwitmer Date 2002-04-10 Time 15:28 Rev Time 3.50
Received By jwitmer Date 2002-04-10 Time 15:28 Sent To  
Notes
2002-04-10 00:00:00BUILDING PLAN REVIEW
 PERMIT# 02030113
 9434 LANTERN BAY CI
 CONT:ENGLE HOMES
 TEL: 968-5671
  
 FL BLDG CODE= 2001 FLORIDA BUILDING CODE
  
 1)- PLANS SUBMITTED AFTER FEBRUARY 28/
 2002 ARE TO BE DESIGNED BY THE 2001
 FLORIDA CODE.
 2)- FL BLDG 1606.1.7 INFORMATION ON
 DRAWINGS RELATED TO WIND SHALL BE ON THE
 CONSTRUCTION DRAWINGS, AND DESIGNED TO
 THE 2001 FL BLDG CODE.
 3)- FL BLDG 1909.3 (EXCEPTION #2 )
 CONCRETE SLABS ON GRADE CONTAINING 6X6/
 W1.4 X W1.4 WELDED WIRE REINFORCEMENT
 FABRIC LOCATED IN THE MIDDLE TO UPPER
 1/3RD OF THE SLAB SHALL BE SUPPORTED BY
 APPROVED MATERIALS OR SUPPORTS AT SPAC-
 ING NOT TO EXCEED 3 FT OR IN ACCORDANCE
 EITH MANUFACTURER'S SPEC.
 4)- ANCHOR SCHEDULE:
 B TYPE ANCHOR 1383 LBS UPLIFT. THE
 SIMPSON HETAL CONNECTION WITH (15)#10D
 NAILS WITH 112LBS SHEAR= 1680 OK.WHEN
 THE SAME 112 LBS SHEAR IS APPLIED TO
 (5)#10D= 560 LBS NOT THE 1383 REQUIRED?
 IT IS NOT CLEAR BUT IF THE TA & TAR
 COMBINED WITH (10) 10D@112=1120 LBS,
 STILL SHORT THE 1383.
 5) TRUSS ENGINEERING IS TO BE DESIGNED
 UNDER THE 140 MPH WIND AS OF 4/1/02.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-08-12 Cont ID  
Sent By btrobaug Date 2002-08-12 Time 17:47 Rev Time 0.00
Received By btrobaug Date 2002-08-12 Time 17:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-22 Cont ID  
Sent By btrobaug Date 2002-03-22 Time 06:46 Rev Time 0.00
Received By btrobaug Date 2002-03-22 Time 06:20 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-20 Cont ID  
Sent By pkrauss Date 2002-06-20 Time 07:58 Rev Time 0.30
Received By pkrauss Date 2002-06-20 Time 07:43 Sent To  
Notes
2002-06-20 00:00:00REIVSION MECHANICAL PERMIT 02030189

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-03-21 Cont ID  
Sent By hmoser Date 2002-03-21 Time 18:16 Rev Time 0.50
Received By hmoser Date 2002-03-21 Time 18:16 Sent To  
Notes
2002-03-21 00:00:00PRIVISO
 REFER TO SECTION 403.3 AND TABLE 403.3
 REQUIRED OUTDOOR VANTILATION AIR
 2001 FLORIDA BUILDING CODE
  
 REFER TO 2001 FLORIDA BUILDING CODE

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-03-09 Cont ID  
Sent By jleech Date 2002-03-09 Time 11:04 Rev Time 0.25
Received By jleech Date 2002-03-09 Time 11:04 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-04-10 Cont ID  
Sent By btrobaug Date 2002-03-22 Time 06:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-03-04 Cont ID  
Sent By gjoyce Date 2002-03-04 Time 15:14 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***