| Plan Review Stops For Permit 02022328 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-07 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-07 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-01-16 |
Time |
13:22 |
Sent To |
FIRE |
|
| Notes |
| 2003-01-16 00:00:00 | SHEETS A1, A2 AND A5 OF THE JI PEREZ | | | PLANS DATED 12/19/02 SATISFY MOST OF | | | THE COMMENTS CONTAINED ON THE 12/03/02 | | | LIST. | | | | | | SHEET A3 DATED 11/5/02 HAS INCORRECT | | | INFORMATION RE: THE EXTERIOR WALL | | | SHEATHING | | | BEING WOOD.PLEASE REVISE AS NECESSARY. | | | | | | SHEET S3 IS DATED 10/9/02 AND DOES NOT | | | ADDRESS THE CHANGE FROM WOOD SHEATHING | | | TOGYPSUM BOARD.PROVIDE A SIGNED AND | | | SEALED STATEMENT FROM THE ENGINEER THAT | | | THE REVISED MATERIAL HAS BEEN | | | CONSIDERED IN HIS DESIGN AND IS | | | ADEQUATE, INCLUDE A | | | FASTENING SCHEDULE. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY, THE PERMIT PLANS | | | STAMPED BY THAT OFFICE, AND A COPY OF | | | THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. | | | CALL 561-233-5025 FOR MORE INFORMATION. | | | | | | PLEASE CONSOLIDATE THE PLANS INTO TWO, | | | CONCISE, CURRENT SETS.REMOVE ANY OLD | | | PAGES AND INSERT ANY NEW ONES AS | | | NECESSARY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-11-26 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-02 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2003-01-16 00:00:00 | COMMENTS ARE UNDER 02080218 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-22 |
Time |
15:28 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-08-22 |
Time |
14:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-19 |
Time |
16:32 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-05-13 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-08 |
Time |
12:47 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2002-11-26 |
Time |
17:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-01-16 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-01-16 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-01-16 |
Time |
15:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-12-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-01-16 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2002-12-10 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2002-12-10 00:00:00 | 1) SEE NOTES UNDER PERMIT # 02080218 | | | 12/10/02 NAM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-12 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-12 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2003-09-12 00:00:00 | COMM BD #60 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-08-22 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-08-22 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2003-08-22 00:00:00 | TO COMM BOARD #32./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-19 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-19 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2003-08-19 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-08 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-08 |
Time |
12:47 |
Sent To |
E |
|
| Notes |
| 2003-05-08 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-06 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2003-02-06 00:00:00 | TO COMM BOARD #15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-27 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-06 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-27 |
Time |
12:24 |
Sent To |
Z |
|
| Notes |
| 2002-12-27 00:00:00 | SENT TO ZONING AS IT SHOWS F IN COMP. | | | ON FIRST TWO REVIEWS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-26 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-26 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2002-11-26 00:00:00 | TO COMM BOARD# 64./WRT. | | | COMM BOARD #63/WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-09-15 |
Time |
14:10 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-09-15 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-09-08 |
Time |
14:14 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-09-08 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | PLAN DENIED | | | 1 REFER TO SECTION 601.4 EXCEPTION # 1 | | | FOR RETURN AIR. | | | 2 NO A/C SPECIFICATIONS ON PLAN. | | | 3 WHAT IS 3X8 METAL DUCT GOING THROUGH | | | ROOF. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-10 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-01-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-01-08 |
Time |
12:54 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-01-08 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2003-01-08 00:00:00 | CALLED DAVID ROMKE, IS EQUIPMENT NEW OR | | | EXISTING?(EQUIPMENT SCHEDULE NOT | | | SHOWN ON PLAN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-02 |
Time |
11:25 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-12-02 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | DENIED: | | | | | | AS PER 2001 FBC 705.6, ALL PENETRATIONS | | | OF A FLOOR, FLOOR/CEILING ASSEMBLY, OR | | | CEILING MEMBRANE OF A ROOF/CEILING | | | ASSEMBLY SHALL BE PROTECTED BY SHAFT | | | ENCLOSURE IN ACCORDANCE WITH 705.2 OR | | | SHALL COMLY WITH 705.6.1.1 OR 705.6.1.2. | | | | | | PROVIDE OUTSIDE AIR CACULATIONS FOR THE | | | RESIDENTIAL SPACES.SHOW COMPLIANCE | | | WITH 2001 FBC(M) 402.2 FOR NATURAL | | | VENTILATION OR TABLE 403.3 MECHANICAL | | | VENTILATION. | | | | | | BEDROOM AREAS REQUIRE RETURN AIR - | | | BALANCED RETURN AIR - 2001 FBC(M) 601.4 | | | RETURN AIR SHALL BE EQUAL TO SUPPLY | | | AIR BY MEANS OF AIR TRANSFER OR A RETURN | | | AIR (JUMPER). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2003-09-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-15 |
Time |
13:40 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-09-15 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2003-09-15 00:00:00 | REVISION OK - DELETED 1ST FLOOR RES. | | | CHANGED ROUTING OF SANT. & WATER LINES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2003-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-05 |
Time |
13:08 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-09-05 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2003-09-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-3 1ST FLOOR SANT. RISER DOES | | | NOT REFLECT SHT P-1 FLOOR PLAN. | | | 2) SHT P-3 SANITARY RISER DIAGRAM FOR | | | THE 1ST FLOOR OFFICE DOES NOT REFLECT | | | THE FLOOR PLAN ON SHT P-1. | | | 3) SHT P-3 1ST FLOOR WATER RISER DOES | | | NOT REFLECT THE FLOOR PLAN ON SHT P-1. | | | 4) PERMIT NUMBER FOR THIS BLDG HAS BEEN | | | CHANGED TO 02080218. PLEASE SUBMIT ANY | | | FUTURE REVISIONS/SUBMITTALS ECT UNDER | | | APPROPRIATE PERMIT NUMBER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-13 |
Time |
14:33 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-01-13 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | PER N. MELICK, OK TO SIGN OFF UNDER | | | FBC-2001. 1 HDCP TOILET ROOM REQUIRED. | | | SIGNED SEALED LETTER REQUIRED FROM ARCH- | | | ITCET. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-01-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-11 |
Time |
14:51 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-01-11 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2003-01-11 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) FROM PREVIOUS REVIEW: PER TABLE 407, | | | SEPARATE TOILET FACILITIES ARE REQUIRED | | | FOR MEN AND WOMEN. 1 WATER CLOSET AND 1 | | | LAV FOR MEN, 1 WATER CLOSET AND 1 LAV | | | FOR WOMEN. SINCE THIS DOES NOT SPACE FOR | | | FUTURE TENANT #2 THE FIXTURE COUNT HAS | | | LOWERED FOR WOMEN'S CALCULATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-12-10 |
Time |
18:50 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-12-10 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2002-12-10 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) PER TABLE 407 SEPARATE TOILET FACIL- | | | ITIES ARE REQUIRED FOR MEN AND WOMEN. | | | 1 WATER CLOSET AND 1 LAV FOR MEN | | | 2 WATER CLOSETS AND 2 LAV'S FOR WOMEN | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | FIXTURES, |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-01-06 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-27 |
Time |
12:24 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2002-11-26 00:00:00 | DENIED 2ND CK LIST, LANDSCAPE PLAN | | | SHOULD SHOW HEDGE INSTEAD OF WALL IN | | | THE FRONT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-03-12 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-12 |
Time |
10:37 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |