| Plan Review Stops For Permit 02022325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-12-02 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-12-02 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-12-02 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2002-12-02 00:00:00 | REVISION #2 DATED 11/21/02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-05-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-14 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-14 00:00:00 | THE THREE SETS OF PLANS PROVIDED CALL | | | OUT A "SPRAY POLYURETHANE FOAM ROOFING | | | SYSTEM"PROVIDE AN EVALUATION REPORT | | | FROM A RECOGNIZED AGENCY FOR THE FIRE | | | AND WIND RESISTANCE CLASSIFICATION.IF | | | THE ATTACHED REPORT FROM METRO DADE FOR | | | ULTRAGUARD PVC IS INTENDED TO BE USED, | | | PLEASE AMEND THE PLANS TO REFLECT THAT. | | | | | | THE PLANS STILL INDICATE THE USE OF | | | PLYWOOD IN THE EXTERIOR WALL, AS NOTED | | | IN THE 3/8/02 CHECKLIST, PLEASE REVISE | | | AS NECESSARY. | | | | | | PLEASE PROVIDE THE PRODUCT EVALUATION | | | REPORT FOR THE SPECIFIC DRYVIT SYSTEM | | | TO BE USED AS PREVIOUSLY REQUESTED.IF | | | THE PAREX SYSTEM IS TO BE USED, PROVIDE | | | THATEVALUATION REPORT AND AMEND THE | | | PLANS ACCORDINGLY. | | | | | | PROVIDE A SPECIFIC CONNECTION DETAIL FOR | | | THE "SUSPENDED CLOUDS" INCLUDING AN | | | ANALYSIS OF THE EXISTING STRUCTURE TO | | | ACCEPT THE ADDED LOADS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-08 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-03-08 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-08 00:00:00 | SHEET A103, PROVIDE TEST REPORTS FOR THE | | | SKYLIGHTS TO BE INSTALLED DEMONSTRATING | | | COMPLIANCE WITH HURRICANE MISSILE | | | IMPACT RESISTANCE. SEE SBC 1707.4 AS | | | AMENDED. | | | | | | PROVIDE TEST REPORTS FOR THE ROOF | | | COVERING FOR WIND AND FIRE.SEE SBC | | | 1503 | | | | | | THE PLANS INDICATE THE PROPOSED USE OF | | | PLYWOOD IN THE EXTERIOR WALLS.THE | | | EXTERIOR WALLS OF BUILDINGS LOCATED IN | | | THE FIRE DISTRICT ARE REQUIRED TO BE OF | | | NON-COMBUSTIBLE CONSTRUCTION.SEE SBC F | | | 102.1 | | | | | | SHEET A202 SHOW THE SERVICE ASVISORS | | | BOOTHS ON AN HC ACCESSIBLE ROUTE. | | | | | | PROVIDE THE EVALUATION REPORT FOR THE | | | DRYVIT SYSTEM TO BE USED. | | | | | | PROVIDE THE HURRICANE MISSILE IMPACT REP | | | ORTS FOR THE GLAZING SYSTEM TO BE USED I | | | N THE SERVICE ADVISORS BOOTHS. | | | | | | WHAT ARE THE "SUSPENDED CLOUDS"? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-24 |
Time |
16:27 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2002-10-24 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-10-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-21 |
Time |
14:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-10-21 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-03-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-11 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-11 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2002-03-11 00:00:00 | ***** NOTE**** | | | | | | SHOW WINDOW OUTLETS MISSING. | | | REDLINED ON PLANS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-17 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-17 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-03-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-06 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-03-27 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2002-03-27 00:00:00 | A) PLEASE PROVIDE MORE DETAILS ON | | | SUSPENDED CLOUDS. | | | B) PLEASE INDICATE EXIT PATHS IN | | | VEHICLE SHOWROOM AREA. | | | C) INTERIOR FINISH CLASSIFICATION | | | INFORMATION REQUIRED ON WALLS AND | | | CEILINGS. | | | D) PLEASE INDICATE FIRE RATING OF | | | EXISTING WALL BETWEEN SERVICE AND | | | OFFICE AREAS. | | | E) BUILDING ADDRESS REQUIRED ON | | | BUILDING. | | | F) PLEASE PROVIDE MORE DETAILS ON | | | POLYURETHANE FOAM ROOFING. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-22 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-22 |
Time |
18:08 |
Sent To |
B |
|
| Notes |
| 2002-11-22 00:00:00 | TO HAROLD./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-06 |
Time |
08:16 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-05-06 |
Time |
07:52 |
Sent To |
FIRE |
|
| Notes |
| 2002-05-06 00:00:00 | PROVISO: | | | | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR WITH | | | NOTIFICATION AS PER 2001 FBC(M) 606.2.1 | | | & NFPA 90A 4-4.4.3. | | | | | | AIR BALANCE REQUIRED - .001 WC OR LESS | | | ACROSS CLOSED DOORS AS PER 2001 FBC(M) | | | 601.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-04 |
Time |
15:53 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-03-04 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2002-03-04 00:00:00 | | | | PLAN SHEET E-M-201, PLEASE CLARIFY | | | EXISTING A/C RETURN FROM ROOMS A109 | | | THROUGH A111.IS THIS RETURN AIR OR | | | EXHAUST?AS PER 1997 SMC 503.3.1, AIR | | | EXHAUSTED FROM BATH, TOILET, URINAL, | | | LAVATORY, LOCKER, COAT ROOM OR SIMILAR | | | ROOMS SHALL NOT BE RECIRCULATED. | | | | | | INDICATE MANUFACTURER, MODEL, & TONNAGE | | | OF EXISTING RTU. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-11 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-11 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-05-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-25 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-25 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2002-05-25 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) COMMENT FROM PREVIOUS REVIEW. PLEASE | | | SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS. NEW ROOF AREA IS | | | BEING ADDED (SEE SHT A-103). ALSO 1/2 | | | AREA OF ALL VERTICAL WALLS. SHOW DETAILS | | | OF HOW WEST ROOF DRAINS ON TO EAST ROOF. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-03-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-03-15 |
Time |
14:38 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2002-03-15 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2002-03-15 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SHT A-103 PLEASE SUBMIT CALCULATIONS | | | FOR ROOF DRAINS. ADD NEW ROOFING SECT- | | | IONS AND 1/2 ALL VERTICAL WALLS. SHOW | | | DETAILS HOW THE WEST ROOF DRAINS ON TO | | | THE EAST ROOF. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|