Plan Review Details - Permit 02022301
| Plan Review Stops For Permit 02022301 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-11 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-15 00:00:00 | SBC 3401.5 REQUIRES THAT THE ENTIRE | | | BUILDING BE BROUGHT UP TO CURRENT CODES | | | WHEN A BUILDING IS INCREASED IN HEIGHT. | | | | | | PROVIDE CALCULATIONS AND PLANS PREPARED | | | BY A PROFESSIONAL ENGINEER | | | DEMONSTRATING THE EXISTING BUILDING | | | WILL SUPPORT ALL OF THE STRUCTURAL | | | LOADS THAT WILL BE IMPOSED UPON IT BY | | | THE ADDITION. SEE SBC 104.2. | | | | | | SHEET S2 SHOWS A PORTION OF THE | | | PROPOSED SECOND FLOOR TO BE PLACED ON | | | THE TOP CHORD OF THE EXISTING TRUSSES | | | WITHOUT ADDITIONAL SUPPORT.THIS IS | | | NOT A VIABLE DESIGN. | | | | | | THE AREA OF THE OPENINGS ON THE WEST | | | ELEVATION OF THE ADDITION EXCEED THE | | | 20% ALLOWED BY SBC TABLE 600 FOR TYPE | | | VI CONSTRUCTION LOCATED 3' TO 10' FROM A | | | PROPERTY LINE.PLEASE REVISE AS | | | NECESSARY. | | | | | | | | | THE ADDITION WILL BE SUBJECT TO IMPACT | | | FEES COLLECTED BY THE COUNTY FOR THE | | | CITY.THE PERMIT PLANS MUST BE STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-03-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-06 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-06 |
Time |
08:41 |
Sent To |
P |
|
| Notes |
| 2002-03-06 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2)NOTE: PLEASE CLARIFY IF THERE IS A | | | DOOR GOING INTO MASTER BEDROOM. NONE | | | SHOWN ON ELECTRICAL PLAN. PLEASE NOTE | | | THAT A SD IS REQ`D INSIDE AND OUTSIDE | | | RM. | | | PLEASE NOTE SD`S WILL BE REQD IN | | | EXISTING BEDROOMS. | | | | | | 3)NOTE: PLEASE NOTE LOAD CALCS SHOW | | | WASHER, BUT NONE SHOWN ON PLANS OR PANEL | | | SCHEUDLE? PLEASE CLARIFY. | | | | | | 4)NOTE: PLEASE NOTE LOADS FOR A/C`S | | | ARE SHOWN AT 5KW AND 8KW AND SHOWN AT | | | 14500 ON LOAD CALCS, PLEASE CORRELATE. | | | | | | 5)NOTE: PLEASE CLARIFY TWO WATER SPA | | | CIRCUITS AND LOADS? ELEC ON E-2 ONLY | | | SHOWS ONE? | | | | | | 6)NOTE: PLEASE NOTE MISSING GFI OUTLET | | | ON KITCHEN PENINSULAR. 210-52-C-3 | | | | | | 7)NOTE: PLEASE CLARIFY DISPOSAL SHOWN | | | ON LOAD CALCS, BUT NOT ON PANEL SCHEDULE | | | ? | | | | | | 8)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTION FOR BEDRROMS, PER 210-12. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-03-11 |
Time |
13:47 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-03-11 |
Time |
13:07 |
Sent To |
P |
|
| Notes |
| 2002-03-11 00:00:00 | *******************DENIED*************** | | | | | | INSUFFICIENT INFORMAION FOR MECHANICAL | | | REVIEW.PLEASE PROVIDE THE FOLLOWING | | | INFORMATION. | | | | | | 1.PROVIDE SIZE OF DUCTWORK BEING | | | INSTALLED. | | | | | | 2.INDICATE GRILLE SIZE & CFM | | | DISTRIBUTION. | | | | | | 3.PROVIDE BTU INFORMATION FOR THE | | | EXISTING GAS WATER HEATER. | | | | | | 4.INDICATE SIZE OF NEW FLUE PIPE. | | | | | | PLEASE NOTE, ADDTIONAL PERMIT REQUIRED | | | FOR GAS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-03-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-11 |
Time |
13:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-03-08 |
Time |
17:22 |
Sent To |
M |
|
| Notes |
| 2002-03-08 00:00:00 | DENIED | | | REFERENCE: SPC-94 | | | | | | 1) SUBMIT SANITARY RISER DIAGRAM FOR | | | SECOND FLOOR. SHOW HOW IT TIES INTO BLDG | | | DRAIN OR SEWER. SHOW PIPE SIZES. | | | 2) IS THERE A MASTER BATH ON THE FIRST | | | FLOOR AND THE SECOND FLOOR? SEE PAGE P1. | | | THE FLOOR PLAN ON THIS PAGE DOES NOT | | | MATCH THE FLOOR PLAN ON PAGE A3. | | | 3) SEPARATE GAS PERMIT REQUIRED. PLEASE | | | SUBMIT PLANS WITH GAS PERMIT APPLICATION | | | INFORMATION REQUIRED FOR PERMIT IS SHOWN | | | ON GAS PERMIT APPLICATION REQUIREMENT | | | SHEET. (SEE ATTACHED). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-03-05 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2002-03-05 |
Time |
11:57 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|