| 2002-03-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 02022228 | | | 105 EVERNIA ST | | | CONT: RAY QUALMANN MARINE | | | TEL: (954) 941-0132 | | | FAX: (954) 943-6430 | | | | | | **********PROVISO********* | | | | | | 1)- THE PLAN DO NOT CLEARLY INDICATE | | | COMPLIANCE WITH FLORIDA ACCESSIBILITY | | | CODE, 1997. AT LEAST ONE ACCESSIBLE | | | ROUTE COMPLYING WITH 4.3 SHALL CONNECT | | | ALLACCESSIBLE SPACES & ELEMENTS. | | | 2)- GROUND AND FLOOR SURFACES ALONG THE | | | ACCESSIBLE ROUTE SHALL COMPLY WITH 4.5 | | | ADDAGG 4.5 A STATIC COEFFICIENT OF | | | FRICTION OF 0.6 IS RECOMMENDED FOR | | | ACCESSIBLE ROUTES, AND 0.8 FOR RAMPS. | | | 3)- RAMPS, THE PLANS DO NOT INDICATE | | | THE RAMPS THAT WILL BE REQUIRED TO CROSS | | | THE BULKHEAD, THESE RAMPS MUST COMPLY | | | WITH ALL REQUIREMENTS OF 4.8. ALL LAND- | | | INGS AND HAND RAILS TO HAVE HANDRAILS ON | | | BOTH SIDES. | | | 4)- GANG PLANKS ARE TO CONFORM TO AN | | | ACCESSIBLE ROUTE, SLOPE AS WELL TRANSI- | | | TION PLATES AT THE TOP AND BOTTOM FOR | | | WHEEL CHAIR ACCESS TO FLOATING DOCKS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X8412 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2002-03-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-06 |
Time |
16:46 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-03-06 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-03-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-03-06 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-03-06 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2002-03-06 00:00:00 | A) ALL PORTABLE FIRE EXTINGUISHERS ARE | | | TO BE CURRENTLY INSPECTED AND | | | SERVICE TAGGED. | | | B) ALL TENTS ASSOCIATED WITH BOAT SHOW | | | ARE TO BE PROPERLY PERMITTED AND | | | INSPECTED BY FIRE RESCUE AND | | | CONSTRUCTION SERVICES. | | | C) ALL FIRE LANES DURING THE EVENT ARE | | | TO REMAIN CLEAR AND UNOBSTRUCTED. | | | D) ALL INGRESS AND EGRESS GATES ARE TO | | | PROVIDE A MINIMUM OF AT LEAST 20 FEET | | | IN CLEAR WIDTH. | | | E) PLEASE INDICATE THE AMOUNT AND | | | LOCATION OF FOAM SUPPLIES FOR | | | FIREFIGHTING. | | | F) OCCUPANT LOAD FOR COCKTAIL BARGES | | | ARE TO BE DETERMINED BY FIRE RESCUE. | | | G) NO COOKING WILL BE ALLOWED ON THE | | | COCKTAIL BARGES. | | | H) ALL ELECTRICAL EQUIPMENT AND THEIR | | | APPURTENANCES TO COMPLY WITH NFPA 70. | | | I) DOCK RAMPS ARE TO HAVE CODE COMPLAINT | | | HANDRAILS AND GAURDRAILS. | | | J) EXISTING FIRE HYDRANTS ARE TO BE | | | PROVIDED PROPER CLEARANCES TO THEM TO | | | ENSURE PROPER OPERATION. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-03-05 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2002-03-05 |
Time |
16:32 |
Rev Time |
0.25 |
| Received By |
ajones |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|