Plan Review Details - Permit 02022169
Plan Review Stops For Permit 02022169
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-04 Cont ID  
Sent By dpalmer Date 2002-04-04 Time 14:03 Rev Time 0.00
Received By dpalmer Date 2002-04-04 Time 13:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-03-20 Cont ID  
Sent By dpalmer Date 2002-03-20 Time 18:10 Rev Time 0.00
Received By dpalmer Date 2002-03-20 Time 17:59 Sent To B
Notes
2002-03-20 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT THERE ARE MANY
 WHITED OUT HAND CHANGES ONPLANS.
 PLEASE NOTE THAT THESE CHANGES NEED TO
 BE CORRECTED BY THE ARCH/ENGINEER OF
 RECORD PER FAC/FS 471.025/481.221.
 PLEASE NOTE THAT LOAD CALCUALTIONS
 NEED TO BE REVISED ALSO TO REFLECT
 CHANGES MADE.
  
 2)NOTE: PLEASE NOTE THE REQ`D EGRESS
 LIGHTING AT REAR OF DWELLING WAS ALSO
 WHITED OUT? PLEASE NOTE EGRESS LT(S)
 IS REQ`D 210-70.
 PLEASE NOTE THIS IS FOR LIBRARY ALSO.
  
 3) PLEASE CLARIFY EQUIPMENT GROUNDING
 METHOD BETWEEN FIRST MEANS OF DISCONNECT
 AND PANEL(S). EQUIPMENT GROUNDING
 CONDUCTORS ARE TO BE SIZED BY 250-122.
 MISSING.
  
 4)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUIT(S) ON PANEL SCHEDULE
 PER 210-12.
  
  
 PLEASE SUBMIT THE ABOVE CORRECTIONS FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-03-21 Cont ID  
Sent By pkrauss Date 2002-03-21 Time 06:52 Rev Time 0.30
Received By pkrauss Date 2002-03-21 Time 06:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-03-25 Cont ID  
Sent By kstevens Date 2002-03-25 Time 14:02 Rev Time 0.00
Received By kstevens Date 2002-03-25 Time 14:02 Sent To  
Notes
2002-03-25 00:00:00RESUBMITTAL - NEW SANITARY RISER DIAGRAM

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-03-09 Cont ID  
Sent By jleech Date 2002-03-09 Time 10:21 Rev Time 0.33
Received By jleech Date 2002-03-09 Time 10:21 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-03-25 Cont ID  
Sent By lhatten Date 2002-03-25 Time 09:10 Rev Time 0.00
Received By ydavis Date 2002-04-04 Time 15:28 Sent To  
Notes
2002-03-25 00:00:00REVIEW & STAMPED PLANS 03/23/2002

Review Stop Z ZONING
Rev No 1 Status P Date 2002-03-05 Cont ID  
Sent By gjoyce Date 2002-03-05 Time 09:03 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved