Plan Review Details - Permit 02021927
Plan Review Stops For Permit 02021927
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-07-10 Cont ID  
Sent By jwitmer Date 2002-07-10 Time 15:26 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-07-10 00:00:00REVISIONS BUILD/STRUC 6/18 6/24 REVIEWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-06-29 Cont ID  
Sent By jwitmer Date 2002-06-29 Time 15:23 Rev Time 0.55
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-29 00:00:00REVIEWED S-2/ S-7L MARTINEZ REV S-1

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-05-28 Cont ID  
Sent By jwitmer Date 2002-05-28 Time 10:46 Rev Time 3.50
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-28 00:00:00STRUCTURE IS LOCATED IN A,A5 FLOOD ZONE!
 ELEVATION CERTIFICATE REQUIRED!

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-09 Cont ID  
Sent By jwitmer Date 2002-04-09 Time 15:27 Rev Time 3.50
Received By jwitmer Date 2002-04-09 Time 11:18 Sent To  
Notes
2002-04-09 00:00:00BUILDING PLAN REVIEW
 PERMIT #02021927
 1111 FLAGLER DR
 CONT: POLO HOMES OF P B INC
 TEL: 833-7331
 CEL: 385-4400
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS STANDARD BUILDING CODE
  
 1) A NEW NOTICE OF COMMENCEMENT WITH THE
 CORRECT ADDRESS.
 2) PLANS DO NOT INDICATE AS TO WHICH
 CODE THEY WERE DESIGNED. JAN/ FEB 2002
 PLANS COULD BE APPLIED FOR PERMIT DESIGN
 ED TO 1997 BUILDING CODE OR THE 2001
 FLORIDA CODE.
 3) THE DESIGNER OF RECORD SHALL INDICATE
 THE CODE, AND DESIGN PARAMETERS AND
 ASSUMPTIONS FOR THIS STRUCTURE.
 4) SBC 3107 FLOOD PLAIN, TO REFER TO THE
 CITY CODE 12.17 THIS LOT IS PARTLY LOCAT
 ED IN A A-5 FLOOD PLAIN.THE REMAINDER OF
 THE LOT IS LOCATED IN A "B" ZONE. THE
 NEW STRUCTURE, IF ANY PORTION IS BUILT
 IN THE FLOOD ZONE THEN THE WHOLE STRUC-
 TURE HAS TO QUALIFY UNDER THE PROVISIONS
 FOR CONSTRUCTION IN FLOOD ZONES.THE
 ELEVATION FOR THE FINISH FLOOR ELEVATION
 IS NOT GIVEN. FOR FLOOD ZONE A-5 THE
 MINIMUM FLOOR ELEVATION FINISH FLOOR
 HEIGTH IS 7'-6" NGVD. NOTE ALL EXTERIOR
 POOL EQUIPMENT, AND A/C UNITS SHALL ALSO
 BE ABOVE THIS ELEVATION. THE OWNERS OF
 THIS SITE MAY INSIST THAT THE BUILDING
 BE BUILT OUTSIDE OF THE FLOOD ZONE FOR
 INSURANCE PURPOSES. A TIE IN SURVEY
 INDICATING THE FINISH FLOOR HEIGTH AND
 THE LOCATION OF THE A-5 ZONE IN REGARDS
 TO THE RELATIONSHIP OF THE BUILDING.
 5) ENERGY EFFICIENCY SHEET NOT SIGNED BY
 THE OWNER OR HIS AGENT OR THE CONTRACTOR
 6) FL STATE STATUTE61G15-23.002 ENGINEER
 TO SEAL ALL DOCUMENTS THAT ARE FOR PUB-
 LICRECORD (SOILS REPORT).
 7) SBC TABLE 500 INDICTES THAT A TYPE VI
 BUILDING UNPROTECTED CAN BE 2 STORIES,
 THE GAME ROOM CONSTITUTES A THIRD STORY,
 THIS WOULD MEAN FOR TYPE VI BUILDING
 1 HR PROTECTED WOULD ALLOW FOR A THIRD
 STORY. ALL STRUCTURAL ELEMENTS WOULD BE
 1 HR PROTECTED. INDICATE FLOOR/CEILING
 ASSEMBLY #'SEITHER UL OR GYPSUM ASSOC.
  
 8) 1606.2.6.2 COMPONENTS & CLADDING, ALL
 PRODUCT TESTING REPORTS REQUIRE 2 COPIES
 SBCCI OR DADE COUNTY REPORTS ARE ACCEPT-
 ED. ALL GLAZED OPENINGS REQUIRE LARGE
 MISSLE RESISTANCE TESTING FOR WINDOWS,
 DOORS AND SKYLIGHTS. IF THE GLAZED UNIT
 HAS NOT BEEN TESTED, THEN STORM SHUTTERS
 SHALL BE REQUIRED.
 THE FRONT DOOR MISSING REPORT.
 GARAGE DOORS: RAYNOR INDICATE AS TO
 WHICH MODEL SHALL BE USED?
 OUTSWING CASEMENT WINDOWS, REPORT HAS
 EXPIRED 1-28-02
 MULLION REPORT SHEET FOR CHART ILLEGABLE
 TO SMALL, REPORT EXPIRED
 STORM SHUTTERS: MISSING REPORT, NOT ON
 A-7 FOR STORM SHUTTERS.
 9) SHEET A-2 INDICATES 2,111 SQ FT.
 SBC 2305.2.2DRAFTSTOPPING EVERY 500 SQ
 FT OR EVERY PART THERE OF.
 10) SHEETS-5 DETAIL #3 FLOOR TRUSSES
 SHALL REQUIRE A FIRE CUT SBC 2305.4.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-03-27 Cont ID  
Sent By btrobaug Date 2003-03-27 Time 15:30 Rev Time 1.00
Received By btrobaug Date 2003-03-26 Time 07:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-07-15 Cont ID  
Sent By sthyng Date 2003-03-24 Time 08:04 Rev Time 0.00
Received By btrobaug Date 2002-07-15 Time 08:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-24 Cont ID  
Sent By btrobaug Date 2002-05-24 Time 09:38 Rev Time 0.00
Received By btrobaug Date 2002-05-24 Time 07:09 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-15 Cont ID  
Sent By btrobaug Date 2002-03-15 Time 13:09 Rev Time 0.00
Received By btrobaug Date 2002-03-15 Time 12:03 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-24 Time 08:04 Rev Time 0.00
Received By sthyng Date 2003-03-24 Time 08:04 Sent To E
Notes
2003-03-24 00:00:00TO BT DESK
 3 SETS AS BUILTS

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-12-04 Cont ID  
Sent By hmoser Date 2002-12-04 Time 15:10 Rev Time 0.75
Received By hmoser Date 2002-12-04 Time 15:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-05-18 Cont ID  
Sent By hmoser Date 2002-05-18 Time 15:57 Rev Time 0.50
Received By hmoser Date 2002-05-18 Time 15:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-03-07 Cont ID  
Sent By kstevens Date 2002-05-18 Time 15:27 Rev Time 0.50
Received By hmoser Date 2002-03-07 Time 19:12 Sent To  
Notes
2002-03-07 00:00:00PLAN DENIED
 A/C PLAN AND ENERGY CALCS DO NOT MATCH.
 NO MANUAL J
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-07-15 Cont ID  
Sent By pschmitz Date 2002-07-15 Time 11:14 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-07-15 00:00:00PLUMBING PLAN REVIEW, APPR PES.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-18 Cont ID  
Sent By btrobaug Date 2002-07-15 Time 09:21 Rev Time 0.00
Received By kstevens Date 2002-05-18 Time 15:24 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-02 Cont ID  
Sent By jleech Date 2002-03-02 Time 06:46 Rev Time 0.75
Received By jleech Date 2002-03-02 Time 06:46 Sent To  
Notes
2002-03-02 00:00:00RISER DIAGRAM;
 1.MISSING BAR SINK.
 2.BOTH TUB BATHS UPSTAIRS NOT VENTED
 PROPERLY. TIE TUB DRAINS INTO LAV
 BRANCH AND TUB WILL BE VENTED BY LAV
 VENT.
 3.3" BRANCH TO MASTER BATH SHOULD BE 4"
 94 SPC TABLE 714.1 NOTE 3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-04-09 Cont ID  
Sent By btrobaug Date 2002-05-24 Time 09:38 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-28 Cont ID  
Sent By sgraham Date 2002-02-28 Time 09:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***