| Plan Review Stops For Permit 02021900 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-06-06 |
Time |
17:54 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-06 00:00:00 | REVISION: PROVIDE 18' PRODUCT APPROVAL | | | FOR GARAGE DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-04-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-04-26 |
Time |
15:31 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-04-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-04-10 |
Time |
09:33 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2002-04-10 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2002-04-10 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 02021900 | | | 8521 EGRET LAKES LANE | | | CONT: CLASSIC DESIGNER HOMES, INC | | | TEL: (954) 345-2727 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS STANDARD BUILDING CODE | | | | | | 1)- FL ENERGY CODE 601. MISSING ENERGY | | | CALS W/ MANUAL J | | | 2)- SBC 1804.2.7.2(3) SOILS REPORT/ W | | | MINIMUM BEARING VALUE. | | | 3)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | A) GARAGE DOORS INDICATE (CIRCLE OR | | | HIGHLIGHT) WHICH DOOR SHALL BE USED. | | | B) THE VARIOUS REPORTS SUBMITTED INDI- | | | CATE THE USE OF IMPACT RESISTANT GLAZING | | | AND THER REPORTS NON IMPACT GLAZING, | | | THERE IS NO INFORMATION AS TO STORM | | | SHUTTERS, OR A KEY INSTALATION PLAN NOR | | | A INSTALLTION SCHEDULE. | | | 4)- TRUSS ANCHOR SCHEDULE, MARK TC-5 | | | INDICATES A ALLOWABLE UPLIFT OF 2233 | | | FOR A DOUBLE STRAP, THE USP CATALOG ONLY | | | ALLOWS 2090 LBS UPLIFT. | | | 5) TRUSS ANCHOR SCHEDULE, MARK TC-7 | | | INDICATES AN UPLIFT OF 1433, THE CATALOG | | | INDICATES 1350 FOR 1 1/2" #10 NAILS, | | | 1520 FOR #10'S CLICHED OVER, WHAT VALUE | | | IS TAKEN FOR 1433? | | | 6) SHEET A-6 TRUSS LAYOUT: | | | A) 2M GIRDER OVER THE SITTING RM 2200 | | | VALUE TO HIGH FOR TYPE ANCHOR VALUED @ | | | 2090. | | | B) GIRDER OVER THE DINING RM. A) 4495LB | | | DETAIL17/A-9 UPLIFT VALUE TO HIGH, PLUS | | | NO FI/F2 VALUE.SAME GIRDER TRUSS, INDICA | | | TES 13,747 SAME DETAIL WHEN THERE IS A | | | COLUMN INDICATED BELOW? | | | C) COVERED PATIO A) INDICATES 1986 LBS | | | UPLIFT, 2 STRAPS VS SHEET A-6 INDICATING | | | A BUCKET? B) SAME DETAIL, SIDE ELEVATION | | | CONNECTION WITH 3396 LBS UPLIFT NO INFOR | | | MATION GIVEN, BUCKET? | | | D) DETAIL 18/A9 INDICATES 3 SIMPON FACE | | | MOUNTED BUCKETS, AT THE CORNER OF A | | | COLUMN, WITH ONE OF THE FLANGES BENT. | | | THIS DETAIL IS FOR SIMPSON BUCKETS, | | | SIMPSON VOIDS ANY WARRENTY ON THERE | | | PRODUCTS,SEE TERMS & CONDITIONS OF SALE | | | & WARRANTY. THE SECOND ISSUE IS THE FLAN | | | GE IS ONLY 2" WIDE, WHAT FACTOR IS TO BE | | | USED IN DERATING BECAUSE OF THE EDGE | | | DISTANCE? | | | E) FAMILY ROOM GIRDER @ SLIDING GLASS | | | DOORS, 5510 LBS UPLIFT, NO CONNECTION TO | | | BEAM? | | | 7) CONTRACTOR TO SUBMIT PLANS TO | | | P B COUNTY FOR COUNTY IMPACT FEE ASSESS- | | | MENT. | | | 8) CITY ADDITIONAL FEE DUE. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-07 |
Time |
15:29 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-07 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-05 |
Time |
13:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-05 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE CORRECT AND RESUBMIT FOR REVIEW. | | | | | | 1} THE #4 GEC IS INCORRECT FOR FOR THE | | | SERVICE SHOWN.MUST BE #2 PER 250-66. | | | | | | 2} THE FEED FROM THE METER TO PANEL "B" | | | IS INCORRECTLY SHOWN WITH A GROUND WIRE | | | PARALLELING THE NEUTRAL. | | | | | | 3} PANEL "B" IS SHOWN AS A "MLO" PANEL. | | | THIS PANEL MUST HAVE A MAIN DISCONNECT | | | PER 230-71,OR HAVE A MAIN DISCONNECT | | | AHEAD OF IT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
08:43 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-04-30 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE CORRECT THE FOLLOWING AND | | | RESUBMIT FOR REVIEW. | | | | | | 1} THE #6 GEC IS INCORRECT FOR THE | | | SERVICE SHOWN.MUST BE #2 PER 250-66. | | | | | | 2} THE RISER DIAGRAM SHOWS BOTH SUB | | | PANELS COMING FROM PANEL "A",ONLY ONE | | | LISTED ON THE THE SCHEDULE.PLEASE | | | CLARIFY. | | | | | | 3} THE SUB FEEDERS IN PVC MUST CONTAIN | | | AN EQUIPMENT GROUND PER 250-122. | | | | | | 4} THE OCP FOR CIRCUIT #5 & 7,IS NOT | | | CORRECT FOR #4 WIRE SHOWN FOR THE SUB | | | FEED. | | | | | | 5} PLEASE LIST AND INCLUDE THE SMALL | | | APPLIANCE CIRCUITS REQUIRED IN | | | 220-16(A),IN THE SCHEDULE AND LOAD | | | CALCS. | | | | | | 6} CIRCUITS #25 & 27IN PANEL "B" FOR THE | | | LIVING ROOM SHOW NO LOADS,PLEASE | | | CLARIFY. | | | | | | 7} THE RISER DIAGRAM SHOWS TWO SUB | | | PANELS BUT ONLY ONE FEED IS SHOWN AND | | | ONLY ONE SUB PANEL SCHEDULE IS | | | SHOWN,PLEASE CLARIFY. | | | | | | IF THERE ARE ANY QEUSTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-03-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-03-20 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-03-20 |
Time |
16:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
08:43 |
Sent To |
E |
|
| Notes |
| 2003-05-05 00:00:00 | BT DESK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-05-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-29 |
Time |
07:56 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-05-29 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2002-05-29 00:00:00 | PROVISO:MECHANICAL PERMIT 02021977 | | | | | | A/C #2 - PLAN INDICATES ONLY 660 CFM | | | DISTRIBUTION.2 1/2 TON ?PLEASE | | | REVISE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2002-04-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-04-29 |
Time |
17:42 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-04-29 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2002-04-29 00:00:00 | PLAN DENIED | | | CFM.ON A/C 1,2 ON PLAN DO NOT MATCH CFM. | | | ON EQUIPMENT,CAN NOT FIND EQUIPMENT IN | | | ARI MANUAL. | | | PLAN REVIEW BY HAROLD MOSER | | | [561]659-8096 EXT 8390 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-03-20 |
Time |
18:01 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-03-21 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2002-03-21 00:00:00 | NO PLANS,ENERGY CALCS,OR MANUAL J | | | HAROLD MOSER [561]659-8096 EXT.8390 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-03-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-03-09 |
Time |
07:24 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-03-09 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2002-03-09 00:00:00 | PROVISO; | | | REVISED RISER DIAGRAM REQUIRED BEFORE | | | FINAL PLUMBING INSPECTION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2002-05-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-29 |
Time |
08:12 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-29 00:00:00 | BUILDING REVIEWED BY J WITMER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-06-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-06-05 |
Time |
10:51 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-03-05 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2002-03-05 |
Time |
09:04 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|