Plan Review Details - Permit 02021755
| Plan Review Stops For Permit 02021755 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-13 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-13 00:00:00 | PROVIDE CLEAR LEGIBLE COPIES OF THE | | | TESTREPORTS FOR THE HURRICANE SHUTTERS | | | TO BE USED TOGETHER WITH AN | | | INSTALLATION SCHEDULE AND THE | | | COMPONENTS TO BE USED MARKED. | | | | | | PROVIDE WDINDLOAD TEST REPORTS FOR THE | | | WINDOWS TO BE USED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-05-06 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-06 00:00:00 | PROVIDE TEST REPORTS AND OR PRODUCT | | | APPROVALS FOR THE NEW WINDOWS, DOORS | | | AND ROOF COVERING.SEE SBC 1707.4. | | | | | | SHOW HOW THE NEW EXTERIOR GLAZED AREAS | | | WILL COMPLY WITH THE CITY'S HURRICANE | | | MISSLE IMPACT REQUIREMENTS. | | | | | | THE ADDITION MAY BE SUBJECT TO IMPACT | | | FEES COLLECTED BY PALM BEACH COUNTY. | | | THE PERMIT PLANS MUST BE STAMPED BY | | | THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-05-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-01 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-01 |
Time |
16:28 |
Sent To |
M |
|
| Notes |
| 2002-05-01 00:00:00 | ~~~~~~~~~~~~~~~~~PROVISO!~~~~~~~~~~~~~~~ | | | | | | 1} PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | 2} PLEASE LIST THE REQ`D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE. PER 210-12 | | | | | | 3} SMOKE DETECTORS PER NFPA-72. | | | | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-05-01 |
Time |
16:50 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-05-02 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2002-05-02 00:00:00 | | | | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-05-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-02 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-02 |
Time |
19:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-05-01 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-28 |
Time |
10:04 |
Rev Time |
0.25 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-01 00:00:00 | PASS & REVIEWED BY ANGELLA VANN 5/1/02 | | | PASS ON TO BLDG 5/1/02 |
|
|
|