Plan Review Details - Permit 02021544
Plan Review Stops For Permit 02021544
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2004-02-26 Cont ID  
Sent By mmclean Date 2004-02-26 Time 08:45 Rev Time 1.25
Received By jwitmer Date 2004-02-26 Time 08:39 Sent To  
Notes
2004-02-26 00:00:00REV 12/12/02OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2003-12-29 Cont ID  
Sent By pkrauss Date 2004-02-05 Time 14:22 Rev Time 0.50
Received By jwitmer Date 2003-12-29 Time 13:11 Sent To Z
Notes
2003-12-29 00:00:00DRIVEWAY REVISIONS & A/C CONDENSOR RE-
 LOCATIONJW 12/29/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-12-30 Cont ID  
Sent By pkrauss Date 2003-12-22 Time 16:13 Rev Time 0.77
Received By jwitmer Date 2002-12-30 Time 16:30 Sent To  
Notes
2002-12-30 00:00:00REVISIONS: DATED 12-12-02OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-07-01 Cont ID  
Sent By btrobaug Date 2002-12-20 Time 18:46 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-04-08 Cont ID  
Sent By jwitmer Date 2002-04-08 Time 10:12 Rev Time 3.50
Received By jwitmer Date 2002-04-08 Time 07:36 Sent To  
Notes
2002-04-08 00:00:00BUILDING PLAN REVIEW
 PERMIT # 02021544
 141 GREGORY PLACE
 O/B MICHAEL SAINT JOHN
 H 586-0484
 B 874-8610 BEEPER
  
 SBC= 1997 STANDARD BUILDING CODE
 SBC*= AMENDMENTS STANDARD BUILDING CODE
  
 1)- MISSING PRODUCT APPROVALS:
 A) WINDOW MULLION REPORT
 B) GARAGE SIDE DOOR ENTRY
 C) OVERHEAD GARAGE DOOR
 D) GLASS BLOCK ALSO WALL THICKNESS OF
 THE GLASS BLOCK?
 2) FIXED WINDOWS REPORT MISSING THE
 TECH. DRAWINGS AND PRESSURES +/-.
 3)- 2ND FLOOR LIVING ROOM REAR ELEVATION
 INDICATES (3) FIXEDWINDOWS VS. FLOOR
 PLAN, A-2, 2ND FLOOR PLAN INDICATES
 (3)25 SH WINDOWS ?
 4)- SHEET S-2 INDICATES HUGHES CONNECTIO
 NS ON PLAN, THEY ARE NO LONGER IN BUSI-
 NES.
 5)- SHEET S-3 CONN SCHEDULE HETAL-16,
 SCHEDULE INDICATES 1365 LBS UPLIFT,
 IS THIS A TYPE-O? SIMPON @ 160% INDI-
 CATES 1635? CONNECTION #1 ON PLAN INDI-
 CATES 1653 WITH 1 CONNECTION?
 SHEET S-4 INDICATES STUCCO SOFFIT, NO
 SPEC AS TO WIRE LATH OR NAILING FOR
 HORIZONTAL SURFACES? SEE ASTM 1063
 7.10.2.3. EXPANED 3/8" RIB LATH AND
 SHEET LATH SHALL BE ATTACHED TO HORIZON-
 TAL WOOD SUPPORTS.7.10.1.1 FOR 3/8 RIB
 LATH SHALL BE ATTACHED AT EACH RIB (4").
 6)- THE CONTRACTOR SHALL SUBMIT THE
 PLANS TO PALMBEACH COUNTY BUILD. DEPT
 FOR IMPACT FEE ASSESSMENT BEFORE THE
 ISSUANCE OF PERMIT.
 7)- PAY STATE RADON FEES TO CITY.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-12-17 Cont ID  
Sent By btrobaug Date 2003-12-17 Time 13:36 Rev Time 0.50
Received By btrobaug Date 2003-12-17 Time 12:50 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-12-30 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:04 Rev Time 0.50
Received By btrobaug Date 2002-12-30 Time 17:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-03-13 Cont ID  
Sent By btrobaug Date 2002-03-13 Time 14:46 Rev Time 0.00
Received By btrobaug Date 2002-03-13 Time 06:42 Sent To R
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-27 Cont ID  
Sent By csiegber Date 2004-01-27 Time 10:13 Rev Time 0.00
Received By csiegber Date 2004-01-27 Time 10:13 Sent To M
Notes
2004-01-27 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-10 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:04 Rev Time 0.00
Received By csiegber Date 2003-12-10 Time 16:03 Sent To E
Notes
2003-12-10 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-20 Cont ID  
Sent By btrobaug Date 2002-12-20 Time 18:46 Rev Time 0.00
Received By btrobaug Date 2002-12-20 Time 18:46 Sent To B
Notes
2002-12-20 00:00:00TO JIM W./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2004-02-05 Cont ID  
Sent By pkrauss Date 2004-02-05 Time 13:42 Rev Time 0.40
Received By pkrauss Date 2004-02-05 Time 12:21 Sent To B
Notes
2004-02-05 00:00:00PROVISO:
 1.CONDENSING UNITS SHALL HAVE
 SUFFICIENT CLEARANCE FOR SERVICE,
 REPAIR, AND INSPECTION.2001 FBC(M)
 306.1.
  
 2.EQUIPMENT INSTALLED AT A HEIGHT
 GREATER THAN 16 FT, SHALL HAVE A
 PERMENANT MEANS OF ACCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2003-12-22 Cont ID  
Sent By csiegber Date 2004-01-27 Time 10:13 Rev Time 0.05
Received By pkrauss Date 2003-12-22 Time 16:11 Sent To B
Notes
2003-12-22 00:00:00NO MECHANICAL REVISION SUBMITTED FOR
 REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-06-20 Cont ID  
Sent By kstevens Date 2003-12-18 Time 17:54 Rev Time 0.50
Received By hmoser Date 2002-06-20 Time 18:57 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-03-07 Cont ID  
Sent By hmoser Date 2002-03-07 Time 17:24 Rev Time 0.50
Received By hmoser Date 2002-03-07 Time 17:23 Sent To  
Notes
2002-03-07 00:00:00PLAN DENIED
 PLANS DO NOT MATCH ENERGY CALCS.
 PLANS SHOW THREE A/C UNITS
 ENERGY CALCS SHOW ONE A/C UNIOT
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-12-18 Cont ID  
Sent By kstevens Date 2003-12-18 Time 17:54 Rev Time 0.50
Received By kstevens Date 2003-12-18 Time 17:54 Sent To M
Notes
2003-12-18 00:00:00REVISION OK - DELETED 2ND FLOOR W/M AND
 ASSOCIATED FLOOR DRAIN

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-15 Cont ID  
Sent By btrobaug Date 2003-12-17 Time 13:36 Rev Time 0.33
Received By jleech Date 2002-06-15 Time 06:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-02 Cont ID  
Sent By jleech Date 2002-03-02 Time 09:40 Rev Time 0.50
Received By jleech Date 2002-03-02 Time 09:40 Sent To  
Notes
2002-03-02 00:00:00DENIED;
 SANITARY RISER DIAGRAM;
 1.MASTER BATH BIDET NOT VENTED.
 2.POWDER BATH UNVENTED (NO VENT ON LAV)
 3.SECOND FLOOR BATH 3 W/C UNVENTED.
 4.NO MORE THAN 2 W/C ON 3" HORIZONTAL
 BRANCH 94 SPC TABLE 714.1 NOTE 3.
 5.BATH 4 TUB NOT VENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT 8369

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2002-04-08 Cont ID  
Sent By btrobaug Date 2002-03-13 Time 14:46 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2004-02-26 Cont ID  
Sent By mmclean Date 2004-02-26 Time 08:45 Rev Time 0.00
Received By mmclean Date 2004-02-26 Time 08:45 Sent To B
Notes
2004-02-26 00:00:00DENIED, NEED TO PROVIDE DIMENSION FOR
 DRIVEWAY (LENTH WIDTH) AND DIMENSION OF
 LOT.

Review Stop Z ZONING
Rev No 2 Status F Date 2004-01-06 Cont ID  
Sent By mmclean Date 2004-01-06 Time 10:42 Rev Time 0.00
Received By mmclean Date 2004-01-06 Time 10:42 Sent To  
Notes
2004-01-06 00:00:00DENIED, NEED 2 COPY OF SURVEY SHOWING
 WORK WITH DIMENSION (LENGTH & WIDTH OF
 DRIVEWAY) NEED TO MEET THE 1000SQ FT OR
 75% OF LANDSCAPE WHICHEVER IS LESS
 TRIED CALLING OWNER BAD NUMBER FILE M MM

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-28 Cont ID  
Sent By jwitmer Date 2003-12-29 Time 13:12 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***