Plan Review Details - Permit 02021424
Plan Review Stops For Permit 02021424
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-02-07 Cont ID  
Sent By dpalmer Date 2003-02-07 Time 11:10 Rev Time 0.50
Received By dpalmer Date 2003-02-07 Time 11:10 Sent To P
Notes
2003-02-07 00:00:00210-52D. NOTED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-06-25 Cont ID  
Sent By btrobaug Date 2003-01-27 Time 12:48 Rev Time 0.00
Received By btrobaug Date 2002-06-25 Time 16:00 Sent To R
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-05-13 Cont ID  
Sent By pkrauss Date 2002-06-19 Time 10:10 Rev Time 0.00
Received By btrobaug Date 2002-05-13 Time 14:26 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-03-12 Cont ID  
Sent By dpalmer Date 2002-03-12 Time 05:55 Rev Time 0.00
Received By dpalmer Date 2002-03-11 Time 16:47 Sent To B
Notes
2002-03-12 00:00:00***************** UNSAT ****************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS ON PANEL SCHEDULE PER
 210-12
  
 4) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
 MISSING FOOTER STEEL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-27 Cont ID  
Sent By btrobaug Date 2003-01-27 Time 12:48 Rev Time 0.00
Received By btrobaug Date 2003-01-24 Time 12:48 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status N Date 2003-02-10 Cont ID  
Sent By pkrauss Date 2003-02-10 Time 15:09 Rev Time 0.20
Received By pkrauss Date 2003-02-10 Time 15:09 Sent To  
Notes
2003-02-10 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 RE-STAMP

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2003-02-07 Cont ID  
Sent By hmoser Date 2003-02-07 Time 09:08 Rev Time 0.50
Received By hmoser Date 2003-02-07 Time 09:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-06-27 Cont ID  
Sent By pkrauss Date 2002-06-27 Time 08:41 Rev Time 0.40
Received By pkrauss Date 2002-06-27 Time 08:40 Sent To R
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2002-06-19 Cont ID  
Sent By pkrauss Date 2002-06-19 Time 09:56 Rev Time 0.45
Received By pkrauss Date 2002-06-19 Time 09:56 Sent To E
Notes
2002-06-19 00:00:00 
 ONLY ONE SET OF ENERGY CALCS SUBMITTED
 & NO MANUAL J CALCULATIONS SUBMITTED.
  
 AS PER 1997 SMC 304.4.1, ACCESS OPENING
 FOR EQUIPMENT IN THE ATTIC SHALL BE NO
 LESS THAN 22" X 36" CONTINUOUS FROM THE
 OPENING TO ITS CONTROLS.AS PER COUNTY
 WIDE AMMENDMENTS 304.4.2 EQUIPMENT IN
 THE ATTIC MUST ALSO HAVE AN ACCESSIBLE
 DISCONNECT SWITCH & A 110-120 VOLT A/C
 GROUNDING TYPE CONVENIENCE OUTLET & A
 LIGHT ON THE SERVICE SIDE OF THE EQUIP.
 CONTROLED BY A SWITCH AT THE ACCESS
 OPENING.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2002-05-28 Cont ID  
Sent By pkrauss Date 2002-05-20 Time 15:26 Rev Time 0.45
Received By pkrauss Date 2002-05-20 Time 15:25 Sent To R
Notes
2002-05-20 00:00:00CODE REVIEWED UNDER THE 1997 SMC
  
  
 NO PLANS SUBMITTED FOR THE FIRST FLOOR.
 ENERGY CALCS INDICATE A CENTRAL UNIT
 WITH CAPACITY OF 116.0, PLANS INDICATE
 (2) 2 1/2 TON UNITS.
  
 PLEASE CLARIFY A/C FOR THE FIRST FLOOR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-03-07 Cont ID  
Sent By kstevens Date 2002-05-18 Time 08:33 Rev Time 0.50
Received By hmoser Date 2002-03-07 Time 18:24 Sent To  
Notes
2002-03-07 00:00:00NO PLANS,ONLEY ONE SET OF ENERGY CALCS,
 NO MANUAL J
 H.MOSER [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 4 Status   Date   Cont ID  
Sent By jgomez Date 2003-02-21 Time 09:40 Rev Time 0.25
Received By kstevens Date 2003-02-07 Time 13:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-07-23 Cont ID  
Sent By dpalmer Date 2003-02-07 Time 11:10 Rev Time 0.00
Received By kstevens Date 2002-07-23 Time 13:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-05-18 Cont ID  
Sent By kstevens Date 2002-05-18 Time 08:33 Rev Time 0.00
Received By kstevens Date 2002-05-18 Time 08:33 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-03-02 Cont ID  
Sent By btrobaug Date 2002-05-13 Time 14:53 Rev Time 0.50
Received By jleech Date 2002-03-02 Time 10:47 Sent To  
Notes
2002-03-02 00:00:00DENIED;
 RISER DIAGRAM;
 1.ONLY 2 W/C PERMITED ON 3" HORIZONTAL
 BRANCH 94 SPC TABLE 714.1 NOTE 3 (4"
 REQUIRED DOWN STREAM OF RISER TO BATH
 2 AND 3.
 2.TUB IN BATH 3 UNVENTED.
 3.BATH 4 2" TRAP AND DRAIN REQUIRED PER
 TABLE 713.1
 4.MASTER BATH BIDET NOT VENTED,2" REQ.
 FOR SHOWER.
 PLUMBING NOTES: PAGE 1
 NOTE 5 SHOCK ARRESTOR SHALL BE INSTALLED
 PER MANUFACTORS RECOMMENDATIONS AND SPC
 SEC 607.8.2.
 NOTE 8 MAXIMUM FLOW FOR SHOWER HEADS IS
 2.5 GAL PER MIN TABLE 406.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2003-02-21 Cont ID  
Sent By jgomez Date 2003-02-20 Time 17:33 Rev Time 1.00
Received By jgomez Date 2003-02-20 Time 17:33 Sent To  
Notes
2003-02-20 00:00:00BUILDING REVIEW COMMENTS:
 1-MISSING SHEETS #2, #3 AND #4 TO HAVE
 A COMPLETE SET OF DRAWINGS.
 2-PROVIDE ALL INFORMATION THAT WAS
 REQUESTED ON PROVISO DATED 6-28-02,
 WHICH WAS A CONDITION AGREED BY THE
 OWNER IN ORDER TO ISSUE THE BUILDING
 PERMIT AND START CONSTRUCTION.
 SEE ATTACHED COPY.
 3-PLANS NEED TO BE RE-STAMPED BY THE
 HISTORICAL PEOPLE PRIOR TO SUBMITTAL
 TO THIS OFFICE.
 4-PROVIDE INFORMATION FOR PLUMBING
 RE-STAMPING AS WELL.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-07-02 Cont ID  
Sent By jgomez Date 2002-06-28 Time 18:29 Rev Time 0.00
Received By jgomez Date 2002-06-28 Time 18:29 Sent To  
Notes
2002-06-28 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A5. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-PROVIDE ATTIC ACCESS @ MASTER BATHROOM
 ROOF. SEC. 2309.6 SBC 1997.
 3-BEFORE INSTALLATION OR CONSTRUCTION
 PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR. SEE PLANS FOR SIZE & SHAPE
 B)GARAGE SIDE DOOR. SEE SIZE ON PLANS.
 C)FRENCH DOORS AS SHOWN ON PLANS.
 D)CASEMENT WINDOWS.
 E)WINDOW MULLIONS AS SPECIFIED ON
 ARCHITECTURAL PLANS.
 F)FIXED WINDOWS AS SHOWN ON PLANS.
 G)ARCHED WINDOWS AS SHOWN ON PLANS.
 H)FIREPLACE UL LISTING & SPECIFICATIONS.
 I)EXTERIOR DOOR AT 3RD FLOOR BALCONY.
 SEE PLANS FOR SIZE AND SHAPE.
  
 4-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 5-SPECIFY SIZE OF ROOF SCUPPERS. SECTION
 1517.6.4 THRU 1517.6.4.3 SBC 1997.
 6-SPECIFY HOW ARE SOIL AND FOOTINGS
 GOING TO BE PROTECTED FROM WATER
 FALLING FROM ROOF VALLEYS & SCUPPERS.
 SEC. 1804.1.6 SBC 1997.
 7-SEE COMMENTS ATTACHED TO TRUSS PACKAGE

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-05-30 Cont ID  
Sent By pkrauss Date 2002-06-27 Time 09:47 Rev Time 4.00
Received By jgomez Date 2002-05-30 Time 17:11 Sent To  
Notes
2002-05-30 00:00:00SECOND CHECKLIST:
 1-AFTER CORRECTING ORIGINAL DRAWINGS,
 PLEASE PAY IMPACT FEES TO PALM BEACH
 COUNTY. BRING BACK STAMPED DRAWINGS
 AND COPY OF PAID RECEIPT.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-CLARIFY DISCREPANCY WITH THE FINISH
 FLOOR ELEVATION. ARCHITECT'S SITE PLAN
 NOTES SAYS 10.5" ABOVE SEA LEVEL.
 SURVEY SAYS 7.5', BUT THE LIVING ROOM
 WILL BE AT 7' ACCORDING TO ARCHITECT'S
 PLANS. (NEED 7.5'MIN. FIN. FL. ELEV.
 AT FLOOD ZONE A5).
 ON THE OTHER HAND NEED TO CONSIDER
 SOUTH NEIGHBOR FOR DRAINAGE SINCE THE
 HOUSE HAS 6.5' FIN. FL. ELEV.
 4-ARCHITECT CHANGED PLANS TO FBC 2001.
 SEE COMMENTS ON PLANS & REVISE/UPDATE
 THEM AS REQUIRED. NOTE: COMMENTS WERE
 NOT REVISED FROM PREVIOUS CHECKLIST.
 **PLEASE, PUT TOGETHER TWO NEW SETS AND
 RETURN ALL THE REVIEWED DRAWINGS TO
 EXPEDITE REVIEW PROCESS.
 5-OWES $662.35 FOR UPDATED VALUATION AND
 RADON FEES.PLEASE PAY ATTACHED RECEIPT
 6-PROVIDE ATTIC ACCESS AT MASTER BATHRM
 WING. SEC. 2309.6 FBC 2001
 7-CLEARLY SPECIFY ON PLANS AREAS TO HAVE
 SAFETY GLASS. IT'S NOT CLEAR IF ALL
 GLASS AREAS WILL BE MISSILE IMPACT
 GLAZING OR NOT. SEE SECTION 2405.1 AND
 SEC 2405.2 FBC 2001.
 8-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR. SEE SIZE, SHAPE AND DESIGN
 PRESSURES SHOWN ON PLANS.
 B)GARAGE SWING DOOR AS SHOWN ON PLANS.
 C)FRENCH DOORS AS SHOWN ON PLANS.
 D)CASEMENT WINDOWS (MISSING DRAWINGS).
 E)WINDOW MULLIONS (FOR IMPACT ASSEMBLIES
 IF USING IMPACT WINDOWS)
 F)FIXED WINDOWS AS SHOWN ON PLANS.
 G)ARCHED WINDOWS AS SHOWN ON PLANS.
 H)FIREPLACE UL LISTING & SPECIFICATIONS.
 I)EXTERIOR DOOR AT 3RD FLOOR BALCONY.
 SEE SIZE AND SHAPE ON DRAWINGS.
 9-REVISE A/C AREA ON ENERGY CALCULATIONS
 TO MATCH A/C AREA ON ARCHITECT'S PLANS
 NOTE: OWNERAGENT TO SIGN AND DATE
 BOTTOM OF FORM.
 10-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS: KEY PLAN AND COMPLETE
 INSTALLATION SCHEDULE.
 11-SPECIFY DRAINAGE & EMERGENCY SCUPPERS
 @ 3RD FL BALCONY. SEC. 1503.4 THRU
 1503.4.4 FBC 2001.
 12-SPECIFY ON PLANS HOW SOIL EROSION IS
 TO BE PREVENTED FROM WATER IMPACT FROM
 ROOF VALLEYS, SCUPPERS. ETC. AS REQ'D
 BY SECTION 1804.1.6 FBC 2001.
 13-AFTER ALL CORRECTIONS ARE DONE TO ALL
 ORIGINAL DRAWINGS, PLEASE TAKE THEM TO
 THE HISTORICAL DISTRICT PLAN REVIEWER
 FOR APPROVAL PRIOR TO SUBMITTING THEM
 TO THE BUILDING DEPARTMENT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-04-05 Cont ID  
Sent By pkrauss Date 2002-05-28 Time 07:45 Rev Time 5.00
Received By jgomez Date 2002-04-04 Time 18:19 Sent To  
Notes
2002-04-05 00:00:00CHECKLIST:
 1-AFTER CORRECTING ORIGINAL DRAWINGS,
 PLEASE PAY IMPACT FEES TO PALM BEACH
 COUNTY. BRING BACK STAMPED DRAWINGS
 AND PAID RECEIPT.
 2-NEED RECORDED NOTICE OF COMMENCEMENT.
 3-CONTRACTOR TO UPDATE INSURANCES.
 4-UPDATE/REVISE DRAWINGS. SEE COMMENTS
 ON PLANS. PLEASE, BRING BACK REVIEWED
 SET TO EXPEDITE REVIEW PROCESS.
 5-OWES $662.35 FOR UPDATED VALUATION AND
 RADON FEES.
 6-PROVIDE EGRESS WINDOW THAT COMPLIES
 WITH SEC. 1005.4 SBC 1997 AT LIBRARY.
 OR, WRITE VISIBLE NOTE UNDER LIBRARY
 STATING THAT ROOM NOT TO BE USED FOR
 SLEEPING PURPOSES (AS PER BUILDING
 OFFICIAL INTERPRETATION).
 7-PROVIDE ATTIC ACCESS AT ENTRY CUPOLA,
 AND MASTER BEDROOM WING. SEE SECTION
 2309.6 SBC 1997.
 8-CLEARLY SPECIFY ON PLANS AREAS TO HAVE
 SAFETY GLASS. SEE PLANS AND SECTION
 2405.2 SBC 1997.
 9-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR. SEE SIZE & SHAPE ON PLANS.
 B)GARAGE SWING DOOR. SEE SIZE AND TYPE.
 C)FRENCH DOORS. SEE SIZES ON PLANS.
 D)CASEMENT WINDOWS (MISSING DRAWINGS)
 E)WINDOW MULLIONS(IMPACT IF USING
 IMPACT WINDOWS).
 F)FIXED WINDOWS. SEE SIZES ON PLANS.
 G)ARCHED WINDOWS. SEE SIZES ON PLANS.
 H)FIREPLACE UL LISTING & COMPLETE SPECS.
 I)EXT. DOOR @ 3RD FL. BALCONY. SEE SIZE
 AND SHAPE ON PLANS.
 10-SPECIFY HEIGHT OF CHIMNEY TO VERIFY
 COMPLIANCE WITH SEC. 2804 SBC 1997.
 11-PROVIDE COMPLETE SPECIFICATIONS FOR
 CEILING INSTALLATION AT PORCHES.
 SPECIFY ALL FASTENERS AS REQUIRED. SEE
 ASTM C-1063. (SEC. 2505.2 SBC 1997)
 12-INFORMATION ON DESIGN CERTIFICATION
 BUILDING CODE COMPLIANCE FORM IS
 INCORRECT. SEE TABLE 1606.2A SBC 1997.
 NOTE: INFORMATION IN THIS FORM SHALL BE
 INCLUDED ON PLANS. NO SEPARATE FORM.
 13-PROVIDE TWO COPIES OF ENERGY CALCS.
 14-PROVIDE CURRENT SOIL TEST REPORT.
 SEE COMMENTS ON REPORT SUBMITTED.
 15-PROVIDE COMPLETE INFORMATION FOR
 SHUTTERS INCLUDING KEY PLAN & COMPLETE
 INSTALLATION SCHEDULE (SEE SAMPLE).
 ALSO, ON STORM PANEL DWGS INDICATE
 SPECIFIC MOUNTING CODITIONS AND ANCHOR
 TYPE AND SPACING TO BE USED ACCORDING
 TO MEAN ROOF HEIGHT, DESIGN PRESSURES,
 PANEL SPAN, EDGE DISTANCE, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO.
 16-SPECIFY DRAINAGE AND SCUPPERS FOR
 BALCONY AT THIRD FLOOR. SEC 1503.1.2.3
 AND 1517.6.4 SBC 1997.

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-28 Cont ID  
Sent By sgraham Date 2002-02-28 Time 12:03 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***