| 2002-03-29 00:00:00 | CHECKLIST: |
| | 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| | 2-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING STAMPED DWGS AND PAID RECEIPT. |
| | 3-SPECIFY RISER HEIGHT AT ENTRY STEPS. |
| | SEE SEC. 1007.3 SBC 1997. |
| | 4-SPECIFY ON PLANS AREAS TO HAVE SAFETY |
| | GLASS. SEC. 2405.2 SBC/97. SEE PLANS. |
| | 5-PROVIDE ATTIC ACCESS AT ENTRY ROOF. |
| | SEC. 2309.6 SBC 1997. |
| | 6-TWO STORY WALL SECTION. PROVIDE SPECS |
| | FOR FIRE CUT AT FLOOR TRUSSES. SEE |
| | SEC. 2305.4 SBC 1997. |
| | 7-FLAT ROOF TO HAVE 1/4"/FT MIN. SLOPE. |
| | SEC. 1503.1.2.3 SBC 1997. |
| | 8-PROVIDE SCUPPERS AT FLAT ROOF. SEE |
| | SEC. 1517.6.4.3 SBC 1997. |
| | 9-SPECIFY DRAFSTOPPING MATERIAL AND |
| | LOCATION AT SECOND FLOOR FRAMING PLAN. |
| | SEC. 2305.2.2 SBC 1997. |
| | 10-PROVIDE COMPLETE SECTION/DETAIL THRU |
| | CHIMNEY. SPECIFY ALL FASTENERS AND |
| | TOP PLATE HEIGHT. SECTION 104.2.2 OF |
| | CITY AMENDMENTS TO SBC 1997. |
| | 11-PROVIDE COMPLETE FRAMING DETAILS AND |
| | SPECS FOR CANVAS CANOPY. SECTION |
| | 104.2.2 CITY AMENDMENTS TO SBC 1997. |
| | 12-SPECIFY CEILING INSTALLATION AT ENTRY |
| | PORCH INCLUDING FASTENERS TO BE USED. |
| | SEE ASTM C1063. |
| | SEC. 2504.2 SBC 1997. |
| | 13-PROVIDE SMOKE DETECTOR @ 1ST FLOOR BY |
| | THE STAIRWAY. SEC. 905.2.2 SBC 1997. |
| | 14-PROVIDE COMPLETE WALL SECTION AT 2ND |
| | FLOOR WALL SUPPORTED ON TRUSS GIRDER @ |
| | WEST WALL OF BEDROOM #3 AND @ SOUTH |
| | WALL OF BEDROOM #2.SPECIFY ALL |
| | FASTENERS TOP AND BOTTOM. |
| | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 |
| | 15-PROVIDE COMPLETE SECTION/DETAIL AND |
| | SPECS AT BALCONY GUARDRAI AND INTERIOR |
| | GUARDRAIL AND RAILINGS THAT COMPLY |
| | WITH SEC. 1608.2 SBC 1997. |
| | 16-PROVIDE SBCCI OR DADE COUNTY (BROWARD |
| | COUNTY ARE NOT ACCEPTED) PRODUCT |
| | APPROVAL FOR: |
| | A)OUTSWING FRENCH DOOR WITH SIDELITES. |
| | B)INSWING FRENCH DOORS. SEE PLANS. |
| | C)UL LISTING AND SPECS. |
| | D)INSWING ENTRY DOOR. (SEE MASTER BEDRM) |
| | E)GARAGE DOOR THAT MEETS THE DESIGN |
| | PRESSURES CALCULATED BY THE ARCHITECT. |
| | F)IMPACT WINDOW MULLIONS. |
| | G)ARCHED WINDOWS. SEE PLANS. |
| | H)FIXED WINDOWS. SEE PLANS. |
| | 17-DESIGN CERTIFICATION FOR BUILDING |
| | CODE COMPLIANCE FORM IS INCORRECT. |
| | A)REVISE MEAN ROOF HEIGHT, VELOCITY |
| | PRESSURE. |
| | B)ARCHITET TO SIGN, SEAL AND DATE FORM |
| | AS REQUIRED BY CHAPTER 481 FL. STATUTE |
| | 18-PROVIDE COMPLETE FRAMING DETAILS AND |
| | SPECS FOR CANOPY AT GARAGE SWING DOOR. |
| | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 |
| | 19-PROVIDE COMPLETE SPECS FOR PARAPET |
| | WALL. HOW IS IT ATTACHED TO CONCRETE |
| | TIE BEAM. STEEL BARS? |
| | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 |
| | 20-TRUSS DRAWINGS: |
| | A)PROVIDE SIGNED, SEALED AND DATED |
| | ENGINEERED DRAWINGS. |
| | B)TRUSS ENGINEER TO SIGN, SEAL AND DATE |
| | TRUSS LAYOUT ALSO. CH. 471 FL. STATUTE |
| | C)ARCHITECT TO REVIEW ALL TRUSS DRAWINGS |
| | PRIOR TO SUBMITTAL. USE REVIEW STAMP. |
| | 21-SEE PLANS FOR ADDITIONAL COMMENTS. |
| | PLEASE RETURN REVIEWED SET AFTER |
| | CORRECTIONS ARE DONE TO THE ORIGINAL |
| | DRAWINGS IN ORDER TO EXPEDITE THE |
| | REVIEW PROCESS. |
| | 22-OWES $379.35 FOR UPDATED VALUE AND |
| | RADON FEES. |