| Plan Review Stops For Permit 02020812 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-06-27 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-06-27 |
Time |
20:42 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-06-27 |
Time |
20:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-06-11 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-06-11 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2002-06-11 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | NOTE: | | | THE PLANS WERE ORIGINALLY SUBMITTED FOR | | | PLAN REVIEW UNDER 1997 STANDARD BUILDING | | | CODE PRIOR TO MARCH 1, 2002.CHANGE OF | | | STATUS FROM PLAN REVIEW TO PERMIT | | | APPLICATION AFTER THAT DATE REQUIRES | | | THAT THE PLANS BE REVIEWED FOR | | | COMPLIANCE WITH 2001 FLORIDA BUILDING | | | CODE.THIS REVIEW HAS BEEN CARRIED OUT | | | TO THE NEW CODE.THE PLANS SHALL NOT | | | MAKE REFERENCE TO THE OUTGOING CODE. | | | | | | SHEET CS, COVER SHEET, SHALL BE AMENDED | | | TO REFER TO 2001 FLORIDA BUILDING CODE | | | INSTEAD OF 1997 SATNDARD BUILDING CODE. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 4/19/02: | | | | | | 3) FBC 1606.1.4PROTECTION OF OPENINGS | | | PLEASE NOTE THAT THE STOREFRONT DOOR | | | PRODUCT APPROVAL NOTICE OF ACCEPTANCE | | | NO. 01-0919.02, SHEET 2, SPECIFIC | | | CONDITIONS, ITEM 3.2 STATES THAT THE | | | DOOR UNIT SHALL ONLY BE INSTALLED AT | | | LOCATIONS PROTECTED BY A CANOPY OR | | | OVERHANG.REFER TO THE PRODUCT APPROVAL | | | FOR FURTHER DETAILS AND DESCRIBE THE | | | METHOD PROPOSED TO RESTRICT WATER | | | INFILTRATION. | | | | | | 6) FBC 11-4.1.3(10)ACCESSIBLE DRINKING | | | FOUNTAIN.BOTH DETAIL 6/A-5 AND 20/A-5 | | | SHOW THE 36" MAXIMUM HEIGHT DIMENSION | | | INCORRECTLY.THE DIMENSION SHOULD SHOW | | | 36" MAXIMUM SPOUT HEIGHT ABOVE THE FLOOR | | | SEE FIG. 27. | | | | | | THE FOLLOWING COMMENT IS A RESULT OF THE | | | REVISIONS TO THE PLANS SINCE THE LAST | | | REVIEW: | | | | | | C) FBC 704.1OCCUPANCY SEPARATION. | | | SHEET A-1, PARTITION TYPE A2 IS REQUIRED | | | TO BE TWO-HOUR FIRE-RATED.AMEND THE | | | PLANS TO SHOW THE UL LISTING REFERENCE | | | FOR THE PROPOSED TWO-HOUR ASSEMBLY. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-04-19 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-04-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-04-19 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2002-04-19 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | SBC = STANDARD BUILDING CODE 1997 | | | SBC*= STANDARD BUILD'G CODE (CITY AMEND) | | | FL ACC CODE = FLORIDA ACCESSIBILITY CODE | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 2/25/02: | | | | | | 3) SBC 1606.4PROTECTION OF OPENINGS. | | | THE DETAIL 4/A-3 REFERENCE TO PRODUCT | | | APPROVALS FOR THE STOREFRONT IS NOTED. | | | HOWEVER, TWO COPIES OF EACH PRODUCT | | | APPROVAL NOTICE OF ACCEPTANCE, WITH | | | ASSOCIATED APPROVED DRAWINGS, MUST BE | | | SUBMITTED. | | | | | | 6) FL ACC CODE 4.1.3(10)ACCESSIBLE | | | DRINKING FOUNTAIN.ON DETAIL 6/A-5, | | | BREAKROOM/KITCHEN ELEVATION, THE 27" | | | MINIMUM LEG CLEARANCE HEIGHT DIMENSION | | | IS SHOWN INCORRECTLY.ADD A SIDE | | | ELEVATION OF THE DRINKING FOUNTAIN TO | | | DEMONSTRATE COMPLIANCE WITH THIS, AND | | | EACH OF THE OTHER, CLEARANCE/REACH | | | REQUIREMENTS SHOWN IN FIG. 27 | | | | | | | | | THE FOLLOWING COMMENTS RESULT FROM THE | | | REVISIONS TO THE PLANS SINCE THE LAST | | | REVIEW: | | | | | | A) FL ACC CODE FIG. 30(A)TOILET STALLS | | | THE REVISION OF THE TOILET LAYOUT IS | | | NOTED.TOILET 1 SHALL HAVE ACCESSIBLE | | | STALL DIMENSIONS OF 60"WIDE AND 59"DEEP | | | FOR A FLOOR MOUNTED W.C.IF THE W.C. | | | WERE CHANGED TO WALL MOUNTED, THEN THE | | | MIN. STALL DIMENSIONS SHALL BE 60"WIDE | | | AND 56"DEEP.ANNOTATE/AMEND THE PLANS | | | TO DEMONSTRATE COMPLIANCE. | | | | | | B) SBC* 104.2.3THE REVISED | | | ARCHITECTURAL PLANS ARE NOT PROPERLY | | | SEALED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-02-25 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-02-25 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-02-25 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2002-02-25 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) THE 'PROJECT INFORMATION' (SHEET CS) | | | MAKES REFERENCE TO '1994 STANDARD | | | BUILDING CODE' WHICH IS NOT A CURRENT | | | CODE. UNTIL MARCH 1,2002 EITHER STANDARD | | | BUILDING CODE 1997 OR FLORIDA BUILDING | | | CODE 2001 MAY BE USED.NEITHER CODE IS | | | REFERENCED ON THE PLANS. THE PLANS MUST | | | STATE WHICH CODE THE WORK IS TO BE | | | CONSTRUCTED TO. | | | | | | 2) FBC* 104.2SHEET A-3, DETAIL 4, | | | IMPLIES THAT A NEW STOREFRONT IS TO BE | | | INSTALLED.ADD NOTES TO THE FLOOR PLAN | | | TO CONFIRM THIS.ALSO, ON THE PERMIT | | | APPLICATION FORM UNDER 'DESCRIBE PROJECT | | | IN DETAIL' THE ENTRY IS SIMPLY "INTERIOR | | | BUILD-OUT" WITH NO REFERENCE TO A NEW | | | STOREFRONT.PROVIDE SUFFICIENT | | | INFORMATION TO DESCRIBE THE SCOPE OF | | | WORK. | | | | | | 3) FBC 1606.1.4PROTECTION OF OPENINGS. | | | SUBMIT A PRODUCT APPROVAL FOR THE NEW | | | STOREFRONT. | | | | | | 4) FBC 2405.2THE GLAZING IN THE NEW | | | STOREFRONT, INTERNAL DOORS OR WITHIN 24" | | | OF ANY DOOR OPENING IS IN A 'HAZARDOUS | | | LOCATION' AND IS REQUIRED TO BE SAFETY | | | GLASS SATISFYING THE REQUIREMENTS OF THE | | | CONSUMER PRODUCT SAFETY COMMISSION 16, | | | CODE OF FEDERAL REGULATIONS, PART 1201 | | | (CPSC 16-CFR, PART 1201).SUBMIT | | | DETAILS TO DEMONSTRATE COMPLIANCE. | | | | | | 5) FBC* 104.2ANNOTATE THE PLANS TO | | | CLARIFY WHERE 'GLAZED' PARTITIONS ARE TO | | | BE INSTALLED.IS THE L-SHAPED PARTITION | | | ADJACENT THE RECEPTION DESK A GLAZED | | | PARTITION, IF SO, IS A CORNER MULLION/ | | | FRAMING PROPOSED?THERE ARE NO NOTES | | | DESCRIBING GLAZED PARTITION PROPOSALS. | | | | | | 6) FBC 11-4.1.3(10)AN ACCESSIBLE | | | DRINKING FOUNTAIN, COMPLYING WITH | | | FBC 11-4.15, SHALL BE PROVIDED. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | IF YOU HAVE ANY QUERIES PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2002-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-07-15 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-07-15 |
Time |
07:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2002-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-07-01 |
Time |
06:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-07-01 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2002-07-01 00:00:00 | ************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE NOTES ATTACHED FROM | | | THE FIRST THREE REVIEWS. | | | | | | | | | | | | | | | 2)NOTE: PLEASE CLARIFY A/C LOAD? | | | A/C AS 6.9? PLEASE NOTE LOAD SHOWN AS 15 | | | KW ON MECH PLANS? | | | PLEASE NOTE LOAD CALCS SHOW AS 16.8KW? | | | PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE ALSO NOTE THAT E-3 STILLS | | | SHOWS A/C EQUIPMENT COMING FROM OTHER | | | SERVICE? SEE LOWER RIGHT HAND CORNER. | | | | | | 4)NOTE: PLEASE SEE SHEET ATTACHED FOR | | | FS/FAC 553.80(2)(B). | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | | | | PLEASE ALSO NOTE WATER HEATER LOAD SHOWN | | | AS 6.0 ON LOAD CALCS AND 1.5 ON PANEL | | | SCHEDULE? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2002-06-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-06-04 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-06-04 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2002-06-04 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT RESPONSE | | | LETTER NOTES COMPLIANCE WITH GROUPING OF | | | MAINS AND SUPPLYING A/C EQUIPMENT FROM | | | PANEL "A", HOWEVER ONLY SHEET E-2 HAS | | | BEEN CHANGED TO REFLECT THOSE CHANGES. | | | PLEASE NOTE THAT E-3 STILL SHOWS OLD | | | CONFIGURATION . | | | | | | 2)NOTE: PLEASE REVISE PANEL SCHEDULE | | | AND LOAD CALCULATIONS TO CORRELATE WITH | | | E-2. | | | | | | ***NOTE** | | | PLEASE DO NOT SUBMIT "EXTRA" REVISED | | | SHEETS. PLEASE TAKE OLD SHEETS OUT AND | | | INSERT NEW/REVISED SHEETS FOR TWO | | | COMPLETE SETS FOR REVIEW. | | | | | | ***** NOTE****** | | | PLEASE ALSO NOTE THAT THERE MAY BE SOME | | | CHANGES NEEDED FOR OTHER TRADES DUE TO | | | THE PLANS NEEDING TO MEET 2001 FBC. | | | PLEASE NOTE THAT PLANS WERE NEVER | | | SUBMITTED FOR PERMIT, ONLY "PLAN REVIEW" | | | PLEASE ALSO NOTE THAT WE ARE STILL UNDER | | | THE "99" NEC AND ONLY CHANGES TO FIRE/ | | | OR MECH MAY CHANGE E-SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION AS | | | SET FORTH IN NOTE(1) WHEN ALL REVIEWS | | | ARE DONE. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-04-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-24 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-24 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2002-04-24 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE CLARIFY IF SECOND SERVICE | | | IS PERMITTED DUE TO DIFFERENT VOLTAGES, | | | (230-2), PLEASE NOTE GROUPING OF MAINS | | | PER 230-72. PLEASE NOTE LIFE SAFETY | | | ISSUE IF FIRE DEPT SHUTS DOWN MAIN FOR | | | ELECTRICAL IN UNIT AND THEN 277/480V | | | IS STILL PRESENT. PLEASE NOTE THAT THIS | | | CREATES A PROBLEM. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-27 |
Time |
6:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-26 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2002-02-26 00:00:00 | ******************** UNSAT ************ | | | | | | 1)NOTE: PLEASE NOTE LOAD CALCULATIONS | | | NEED TO BE SHOWN. WATTS PER SQ FT, 180VA | | | PER OUTLET, 220-3,220-11,220-11,220-13, | | | PLEASE ALSO NOTE THAT ALL CONTINUOUS | | | LOADS NEED TO BE SHOWN AT 125%. | | | 215-2/3,230-42. | | | | | | 2)NOTE: PLEASE NOTE THAT A/C SYSTEM IS | | | SHOWN BEING FED FROM ANOTHER SERVICE | | | THAT FEED ANOTHER SPACE. PLEASE NOTE, | | | THIS IS NOT PERMITTED. | | | SYSTEM NEEDS TO COME FROM THE SAME | | | SERVICE AS EACH TENANT SPACE. 230-72, | | | 230-2 ETC. | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 4)NOTE: PLEASE NOTE THAT INSTANT WATER | | | HEATER IS SHOWN AS SINGLE PHASE 120V | | | ON E-2 AND PANEL SCHEDUE AS 3-PHASE? | | | PLEASE CLARIFY. | | | | | | 5)NOTE: PLEASE NOTE MISSING OUTLET(S) | | | FOR "SHOW" WINDOWS. 210-62. | | | | | | 6)NOTE: PLEASE NOTE MISSING SIGN CIRCUIT | | | PER 600-5. NOTE #8 ON E-1 NEEDS TO BE | | | SHOWN. | | | | | | 7)NOTE: PLEASE NOTE LOAD CALCS FOR TRACK | | | LIGHTING NEEDS TO BE SHOWN. 220-12B. | | | | | | 8)NOTE: PLEASE NOTE THAT PANEL IS SHOWN | | | IN A STORAGE ROOM. PLEASE NOTE ON PLANS | | | THAT AREA MUST MEET 110-26 AND OUTLINED | | | MARKINGS ARE TO PAINTED ON FLOORS TO | | | SHOW CLEARENCE REQ`MENTS.110-26 AND | | | NOTE, 384-7. | | | | | | 9)NOTE: PLEASE NOTE THAT NOTE #2 UNDER | | | WIRE AND CABLE ON E-3. MENTIONS COLOR | | | CODING PER NEC. | | | PLEASE NOTE THAT PER LOCAL AMENDMENTS, | | | 215-8 | | | 120/208V, BLK/RED/BLUE AND 277/480V | | | BROWN/PURPLE/YELLOW. | | | PLEASE NOTE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-01 |
Time |
14:20 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2002-06-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-06-28 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-06-28 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2002-05-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-30 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-30 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-07 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-07 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-02-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-19 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-19 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2002-02-19 00:00:00 | 1) PLEASE INDICATE FIRE RATINGS OF | | | EXISTING TENANT DEMISING WALLS. WHAT | | | ARE THE OTHER OCCUPANCY TYPES ADJACENT | | | TO THE PROPOSED TD WATERHOUSE. | | | 2) THE KEY PLAN INDICATES THAT THE | | | REAR ROOM IS LABELED STORAGE. OTHER | | | DRAWINGS INDICATES THAT IT IS A | | | BREAKROOM. | | | 3) NO FIRE SPRINKLER DRAWINGS PROVIDED. | | | 4) NO FIRE ALARM EQUIPMENT SHOWN ON | | | THE PLANS. | | | 5) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR THE | | | WALLS AND CEILINGS OF PROPOSED SPACE. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-06-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-22 |
Time |
10:22 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-06-22 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2002-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-06-10 |
Time |
13:49 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-06-10 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2002-06-10 00:00:00 | PROVSIO: | | | PLAN SHEET PM-1 - (OUTSIDE AIR CALCS) | | | AS PER CONVERSATION W/STEVE CLEMIT/ENG. | | | | | | | | | 1.PROVIDE OUTSIDE AIR CALCULATIONS AS | | | PER 2001 FBC(M) TABLE 403.3 OR | | | ASHRAE 62-89. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-04-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-17 |
Time |
16:49 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-04-17 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-01 |
Time |
13:55 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2002-03-01 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2002-03-01 00:00:00 | | | | PLANS REVIEWED UNDER THE 2001 FLORIDA | | | BUILDING CODE, MECHANICAL | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | | | | 1.PROVIDE LOCATION OF OU-1.PLEASE | | | NOTE AS PER 2001 FBC, MECH 306.5 - | | | EQUIPMENT REQUIRING ACCESS ARE | | | INSTALLED ON ROOFS OR ELEVATED | | | STRUCTURES AT A HEIGHT EXCEEDING 16 | | | FEET, AN APPROVED PERMANENT MEANS OF | | | ACCESS IS REQUIRED. | | | | | | 2.PROVIDE INFORMATION AS TO WHAT WILL | | | BE KEPT IN THE "STORAGE" SPACE. | | | | | | 3.SEE ELECTRICAL PLAN REVIEW COMMENT | | | #3. | | | | | | PLEASE NOTE, AS PER 2001 FBC, MECHANICAL | | | 401.5, OUTSIDE AIR EXHAUST & INTAKE | | | OPENINGS SHALL BE LOCTED A MINUMUM OF | | | 10 FT FROM LOT LINES OR BUILDINGS ON | | | THE SAME LOT.401.5.2, EXHAUST | | | OPENINGS SHALL NOT BE DIRECTED ONTO | | | WALKWAYS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-07-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-07-05 |
Time |
19:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-07-05 |
Time |
19:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2002-06-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-12 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-12 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2002-06-12 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 11 | | | FBC-2001 PLUMBING | | | | | | 1) CODE REFERENCE SHALL BE FBC FOR ANY | | | APPLICATION RECIEVED AFTER FEBRUARY 28, | | | 2002. PLEASE CHANGE ALL CODE REFERENCES | | | 2) PER FBC-2001 TABLE 403.1 A SERVICE | | | SINK IS REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-05-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-04 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-04 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2002-05-04 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) SHTS A-1/A-2 PER RULE 9B-7.0043 FLA. | | | ADMIN CODE, (SEE FIG 30(E)) A LAVATORY | | | SHALL BE PROVIDED WITHIN THE ACCESSIBLE | | | TOILET STALL. | | | 2) SHTS A-1/A-2 WOMENS RESTROOM, THE | | | 5' TURNING RADIUS SHALL BE IN THE TOILET | | | ROOM, NOT THE STALL. | | | 3) ALL HDCP LAVSSHALL BE 1'3" TO CENT- | | | ER OFF THE WALL AND BE CENTERED IN THE | | | 30" CLEAR FLOOR SPACE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-02-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-02-27 |
Time |
13:52 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-02-27 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2002-02-27 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) SHT CS MINIMUM FACILITIES CALL FOR | | | 1 W/C & 1 LAV MALE - 2 W/C'S & 2 LAV'S | | | FEMALE. ALSO 1 DRINKING FOUNTAIN REQUIR- | | | ED. SPC TABLE 407 & SEC 407.1.3. | | | 2) SHT A-2 SHOW CLEAR FLOOR SPACE FOR | | | ALL HDCP FIXTURES. LAV'S, W/C'S, DRINK- | | | ING FOUNTAIN, AND BREAK ROOM SINK. | | | 3) SHT A-5 DETAIL #6, PLEASE SHOW COMP- | | | LIANCE WITH FACBC SEC 4.24 AND ALL SUB- | | | SECTIONS. | | | 4) SHT A-5 SHOW DETAIL OF DRINKING FOUN- | | | TAIN. COMPLY WITH FACBC SEC 4.15 AND ALL | | | SUBSECTIONS, AND SEC 4.1.3(10) FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | 5) SHT PM-1 PLEASE SUBMIT MANUFACTURE'S | | | INFORMATION ON INSTANTANIOUS W/HEATERS. | | | SHOW LISTING FOR PRODUCT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2002-03-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-03-01 |
Time |
14:20 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|