Plan Review Details - Permit 02020780
Plan Review Stops For Permit 02020780
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-09-02 Cont ID  
Sent By jwitmer Date 2002-09-02 Time 15:34 Rev Time 0.25
Received By jwitmer Date 2002-09-02 Time 15:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-04 Cont ID  
Sent By btrobaug Date 2003-08-04 Time 14:01 Rev Time 1.00
Received By btrobaug Date 2003-08-04 Time 14:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-09-06 Cont ID  
Sent By alange Date 2003-07-23 Time 10:28 Rev Time 0.50
Received By btrobaug Date 2002-09-06 Time 17:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-07-30 Cont ID  
Sent By mcarsill Date 2002-07-30 Time 09:29 Rev Time 0.00
Received By mcarsill Date 2002-07-30 Time 09:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-20 Cont ID  
Sent By csiegber Date 2003-08-20 Time 15:58 Rev Time 0.00
Received By csiegber Date 2003-08-20 Time 15:57 Sent To  
Notes
2003-08-20 00:00:00TO PK DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-23 Cont ID  
Sent By alange Date 2003-07-23 Time 10:28 Rev Time 0.00
Received By alange Date 2003-07-23 Time 10:26 Sent To E
Notes
2003-07-23 00:00:00TO BT DESK
 TO DP DESK

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-09-15 Cont ID  
Sent By drunnels Date 2003-09-15 Time 14:16 Rev Time 0.50
Received By drunnels Date 2003-08-27 Time 08:46 Sent To  
Notes
2003-09-15 00:00:00OK PER HAROLD M PERMIT # CORRECTED DR

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-09-23 Cont ID  
Sent By pkrauss Date 2002-09-23 Time 16:25 Rev Time 0.15
Received By pkrauss Date 2002-09-23 Time 16:25 Sent To  
Notes
2002-09-23 00:00:00PLANS APPROVED 3-14-02

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-03-26 Cont ID  
Sent By kstevens Date 2003-03-26 Time 12:42 Rev Time 1.00
Received By kstevens Date 2003-03-26 Time 12:42 Sent To  
Notes
2003-03-26 00:00:00HEALTH DEPT STAMP ON POOL PLAN PERMIT
 NUMBER 02110476

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-03-25 Cont ID  
Sent By kstevens Date 2003-03-25 Time 12:54 Rev Time 1.50
Received By kstevens Date 2003-03-12 Time 17:56 Sent To  
Notes
2003-03-25 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PREVIOUS REVIEW COMMENTS HAVE NOT
 BEEN ADDRESSED.
  
 PLANS SHALL BE ROUTED TO THE PALM BEACH
 HEALTH UNIT.
  
 SHOW CLEAR FLOOR SPACE FOR URNAL
  
 WATER RISER - WATER HAMMER ARRESTORS
 SHALL BE LOCATED NEAR THE FIXTURES IN AN
 "EFFECTIVE RANGE"
  
 BACKFLOW PREVENTER IS REQUIRED ON WATER
 SERVICE TO POOL BATH BLDG.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-09-18 Cont ID  
Sent By kstevens Date 2002-09-18 Time 09:36 Rev Time 0.00
Received By kstevens Date 2002-09-18 Time 09:36 Sent To  
Notes
2002-09-18 00:00:00DENIED
 REFERENCE: SPC-94 - FACBC-97
  
 1) PLANS SHALL BE ROUTED TO THE PALM
 BEACH COUNTY HEALTH UNIT, DIVISION OF
 ENVIRONMENTAL HEALTH, 901 EVERNIA ST
 WPB (561) 355-3018 EXT 1134
 2) SHT A2.51 PLEASE SHOW CLEAR FLOOR
 SPACE FOR URNAL. (30"X48")
 3) SHT A2.51 URNAL HEIGHT SHALL BE 17"
 PER 4.18.2. PLEASE SHOW ON TOILET ELEV-
 ATION5/A2.51.
 4) SHT P2.51 WATER RISER DIAGRAM, WATER
 HAMMER ARRESTO SHALL BE LOCATED NEAR THE
 FIXTURES IN AN "EFFECTIVE RANGE" NOT AT
 THE TOP OF THE DROP AS SHOWN. PDI WH-201
 AND MANUFACTURES INSTALLATION INSTRUCT-
 IONS.
 5) SHT P2.51 WATER RISER DIAGRAM, A
 BACKFLOW PREVENTER IS REQUIRED ON WATER
 SERVICE FOR POOL BATH BLDG.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-06-25 Cont ID  
Sent By sgraham Date 2002-06-25 Time 12:08 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***