Plan Review Details - Permit 02020700
| Plan Review Stops For Permit 02020700 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-20 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2002-05-20 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-05-20 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2002-05-20 00:00:00 | BUILDING PLAN REVIEW | | | ******PROVISO******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | SBC = STANDARD BUILDING CODE 1997 | | | SBC*= STANDARD BUILD'G CODE (CITY AMEND) | | | | | | --PROVISO-- | | | TABLE 704.1 FIRE RATING OF THE OCCUPANCY | | | SEPARATION WALL BETWEEN 'TENANT 2' AND | | | 'TENANT 3'. THE RESPONSE TO COMMENT NO.3 | | | WAS NOTED ON THE COMMENT SHEET ONLY. | | | THIS INFORMATION SHALL BE ADDED TO THE | | | PLANS BY THE ARCHITECT OF RECORD OR | | | CONFIRMED BY LETTER.2 HOUR FIRE RATING | | | IS REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-02-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-17 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2002-02-21 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2002-02-21 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 659 8096 EXT 8499 | | | | | | REFER TO MECHANICAL AND FIRE REVIEW | | | COMMENTS ALSO. | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) UNTIL MARCH 1, 2002 EITHER STANDARD | | | BUILDING CODE 1997 OR FLORIDA BUILDING | | | CODE 2001 MAY BE USED.NEITHER CODE IS | | | REFERENCED ON THE PLANS.STATE WHICH | | | CODE THE WORK IS TO BE CONSTRUCTED TO. | | | | | | 2) ANNOTATE THE PLANS TO STATE THE USE/ | | | OCCUPANCY OF THE MAIN TENANT 3 AREA | | | AROUND THE SPRAY BOOTH. | | | | | | 3) TABLE 704.1THE OCCUPANCY SEPARATION | | | WALL TO 'TENANT 2' SHALL HAVE A TWO-HOUR | | | FIRE-RATING.THIS REQUIREMENT STANDS | | | WHETHER 'TENANT 3' IS CONSIDERED | | | FACTORY-INDUSTRIAL OR HAZARDOUS (SUB- | | | CLASSIFICATION H3, SEE FBC TABLE 308.2C) | | | AMEND THE PLANS TO DEMONSTRATE | | | COMPLIANCE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | IF YOU HAVE ANY QUERIES PLEASE CALL: | | | ROBERT BROWN(561) 659 8096 EXT 8499 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-14 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-14 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-05-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-05-10 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-05-10 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-02-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-14 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-21 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2002-02-14 00:00:00 | 1) "EXHAUST DUCT DISCHARGE POINT SHALL | | | BE AT LEAST 6 FEET FROM ANY EXTERIOR | | | WALL OR ROOF".RE: NFPA 1, SECTION | | | 17-3.5.4. | | | 2) "NO SMOKING OR OPEN FLAMES" IN LARGE | | | LETTERS ON A CONTRASTING BACKGROUND | | | SHALL BE INSTALLED IN ALL SPRAY AREAS | | | AND PAINT STORAGE ROOMS".RE: NFPA 1, | | | SECTION 17-3.8.8. | | | 3) THE SPRAY BOOTH SHALL BE ELECTRICALLY | | | GROUNDED AND BONDED".RE: NFPA 1, SECTION | | | 17-3.4.5. | | | 4) ELECTRICAL EQUIPMENT AND APPURTENANT | | | EQUIPMENT TO COMPLY WITH NFPA 1, SECTION | | | 17-3.4.1. | | | 5) PORTABLE FIRE EXTINGUISHERS | | | REQUIRED. RE: NFPA 1, SECTION 17-3.7.6. | | | 6) SIGNED AND SEALED LEGAL SURVEY | | | REQUIRED OR A LEASE AGREEMENT WITH | | | RAILROAD FOR USE OF RAILROAD EASEMENT. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-05-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-05-17 |
Time |
15:04 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-05-17 |
Time |
15:02 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2002-02-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-20 |
Time |
16:47 |
Rev Time |
2.00 |
| Received By |
pkrauss |
Date |
2002-02-20 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2002-02-20 00:00:00 | | | | | | | 1.PROVIDE INFORMATION ON THE STORING | | | OF THE TOOLING GEL COAT & POLYESTER | | | LAMINATING RESIN. | | | | | | 2.PROVIDE VENTILATION CALCULATIONS. | | | | | | 3.WHAT TYPE OF OCCUPANCY IS THE | | | ADJOINING TENANTS. | | | | | | SEE COMMENTS BY FIRE DEPT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-02-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-02-14 |
Time |
10:23 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2002-02-14 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2002-02-14 00:00:00 | FIXTURES RESET ONLY |
|
|
|