Plan Review Details - Permit 02020454
| Plan Review Stops For Permit 02020454 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2002-03-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-21 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-06 00:00:00 | NEEDS COUNTY IMPACT FEE REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-14 |
Time |
06:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-14 |
Time |
06:34 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-12 |
Time |
14:13 |
Sent To |
P |
|
| Notes |
| 2002-02-12 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2)NOTE: PLEASE NOTE THAT MAIN DISCONNECT | | | IS NOT SHOWN NEXT TO METERCAN. PLEASE | | | SHOW. | | | | | | 3)NOTE: PLEASE NOTE THAT NEW A/C COND. | | | UNITS IS NOT SHOWN. DISC PER 440-11 AND | | | GFI PER 309.2 MECH CODE | | | | | | 4)NOTE: PLEASE NOTE THAT EQUIPMENT | | | GROUNDING IS MISSING BETWEEN MAIN DISC | | | AND PANEL.PER 250-122 | | | | | | 5)NOTE: PLEASE LOAD FOR WATER HEATER, | | | LOAD CALCS SHOW "GAS" AND PANEL SCHEDULE | | | SHOW ELECTRICAL.?? | | | | | | 6) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | 7)NOTE: PLEASE CLARIFY DRYER LOAD? | | | PANEL SCHEDULE SHOWS 1-POLE 20A AND LOAD | | | | | | | | | 8)NOTE: PLEASE CLARIFY LOAD FOR "NEW" | | | AHU. PANEL SCHEDULE SHOWS 60A OCP WITH | | | 45A LOAD AND LOAD CALCS SHOW 5KW LOAD?? | | | PLEASE CORRELATE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-06-08 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-06-08 |
Time |
07:33 |
Rev Time |
0.33 |
| Received By |
hmoser |
Date |
2002-06-08 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-02-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-21 |
Time |
14:04 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2002-02-21 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-14 |
Time |
06:34 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2002-02-20 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2002-02-20 00:00:00 | REVIEWED UNDER SPC-94 CODE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-12 |
Time |
14:15 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|