Plan Review Details - Permit 02020324
Plan Review Stops For Permit 02020324
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-01-14 Cont ID  
Sent By hpiskura Date 2003-01-14 Time 12:09 Rev Time 0.00
Received By hpiskura Date 2003-01-14 Time 11:54 Sent To P
Notes
2003-01-14 00:00:00REVISON #4 DATED 10/30/02 POOL MECHANICS
 , COLLINS PE

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-04-24 Cont ID  
Sent By hpiskura Date 2002-04-24 Time 13:47 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-03-01 Cont ID  
Sent By hpiskura Date 2002-03-01 Time 09:42 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-03-01 00:00:00A REVIEW BY THE BUILDING ENGINEER OF
 RECORD IS REQUIRED.

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2002-12-30 Cont ID  
Sent By dpalmer Date 2002-12-30 Time 16:30 Rev Time 0.25
Received By dpalmer Date 2002-12-30 Time 16:30 Sent To P
Notes
2002-12-30 00:00:00SENT TO PLUMB,
 REVISED EQUIPMENT LAYOUT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-16 Cont ID  
Sent By dpalmer Date 2002-04-16 Time 15:18 Rev Time 0.00
Received By dpalmer Date 2002-04-16 Time 15:18 Sent To  
Notes
2002-04-16 00:00:00NOTE:
 NOTE THAT MAIN PLANS NEED TO BE REVISED
 FOR ADDED POOL EQUIPMENT FOR POOL PANEL.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-02-14 Cont ID  
Sent By dpalmer Date 2002-02-14 Time 10:34 Rev Time 0.00
Received By dpalmer Date 2002-02-14 Time 10:34 Sent To  
Notes
2002-02-14 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NO ELECTRICAL
 WIRING DIAGRAM WAS SUBMITTED FOR REVIEW.
  
 PLEASE SHOW WIRING/CONDUIT/PANEL
 SCHEDULES OR WHERE FEEDS ARE COMING FROM
 AND DISCONNECTS ETC
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2002-02-14 Cont ID  
Sent By mcarsill Date 2002-02-14 Time 14:59 Rev Time 0.00
Received By mcarsill Date 2002-02-14 Time 14:59 Sent To  
Notes
2002-02-14 00:00:001) CHEMICAL STORAGE ROOM TO COMPLY
 WITH NFPA 430, THE STORAGE OF OXIDIZERS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-04-25 Cont ID  
Sent By hpiskura Date 2003-01-14 Time 12:09 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2002-04-25 00:00:00SEE PROVISOS ATTACHED TO SHEET 5 OF
 PERMIT PLANS.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-25 Cont ID  
Sent By kstevens Date 2002-02-25 Time 10:27 Rev Time 0.00
Received By kstevens Date 2002-02-21 Time 19:36 Sent To  
Notes
2002-02-25 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) SHT 5 CHEMICAL STORAGE ROOM, 4" FLOOR
 DRAIN SHALL DRAIN TO SANITARY.
 2) SHT 5 ALL WASTE TO DRAIN TO SANITARY
 AND OVERFLOW SHALL DRAIN TO STORM OR
 DRAIN FIELD.
 3) SHT 5 POOL WASTE DETAIL & NOTE #9,
 ALL WASTE TO SANITARY AND OVERFLOW TO
 STORM.
 4) SHT 5 CHLOLRINE ROOMS SHALL HAVE: CON
 TINUOUS FORCED DRAFT VENTILATION 64E-9.
 007(16)(A)1.A.
 5) SHT 5 EB TO DRAIN INDIRECTLY TO FLOOR
 SINK LOCATED NEAR EQUIPMENT SO PIPING
 DOES NOT RUN ACROSS FLOOR. FLOOR DRAIN
 SHOWN BUT FLOOR SINK REQUIRED.
 6) PLEASE SUBMIT POOL HEATER MANUFACTURE
 SHEET FOR REVIEW. MUST SHOW BTU'S AND
 APPROVING AGENCY, (LISTING AGENCY).
 7) PLEASE SUBMIT MSDS FOR CHEMICALS USED
 FOR POOLS.
 8) MENS ROOM IN MASTER PLAN (01030147)
 DO NOT SHOW URNAL. 64E-9.006(2)(F)1, SEE
 CHART.
 9) CHLORINE ROOM DOOR SHALL OPEN OUT AND
 SHALL NOT BE LOCATED ADJACENT TO THE
 FILTER ROOM ENTRANCE. 64E-9.007(16)(A)(1
 )A
  
 REVEIW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-13 Cont ID  
Sent By sgraham Date 2002-02-13 Time 13:57 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***