Plan Review Details - Permit 02020133
| Plan Review Stops For Permit 02020133 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2002-02-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-11 |
Time |
12:29 |
Rev Time |
0.05 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-05-22 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2002-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-06 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-02-05 |
Time |
17:52 |
Sent To |
M |
|
| Notes |
| 2002-02-06 00:00:00 | *****************PROVISO**************** | | | PLEASE NOTE AND COMPLY WITH THE | | | FOLLOWING BEFORE CALLING INSPECTION: | | | | | | 1) PROVIDE A.I.C. RATINGS AS PER 110-9 & | | | 110-10. | | | | | | 2) RISER AS PER 230-28. | | | | | | 3) FEEDER CONDUCTORS IDENTIFIED AS PER | | | 215-8 CITY AMMENDMENTS.(SEE NOTES ON | | | PLAN.) | | | | | | 4) REMOVE #6 GROUNDING ELECTRODE | | | CONDUCTOR FROM MAIN DISCONNECT,USE ONLY | | | THE ONE FROM THE METER ENCLOSURE TO | | | PREVENT PARALLEL PATHS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT.8392 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-08 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-08 |
Time |
16:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-06 |
Time |
11:23 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-02-08 |
Time |
08:00 |
Sent To |
B |
|
| Notes |
| 2002-02-06 00:00:00 | ****************PROVISO!**************** | | | PLEASE NOTE AND CORRECT THE FOLLOWING BE | | | FORE CALLING INSPECTION: | | | 1) PROVIDE A.I.C. RATING. | | | | | | 2) COMPLY WITH 230-28 WHEN INSTALLING RI | | | ER. | | | | | | 3) IDENTIFY FEEDER CONDUCTORS AS PER 215 | | | -8,CITY AND COUNTY AMMENDMENTS. | | | | | | 4) ELIMINATE THE #6 GROUNDING CONDUCTOR | | | FROM MAIN DISCONNECT TO PREVENT PARALLEL | | | PATHS.USE ONLY THE ONE FROM THE METER E | | | NCLOSURE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT.8392 |
|
|
|