| Plan Review Stops For Permit 02020081 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-02 |
Time |
06:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-12-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-18 |
Time |
17:39 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-12-18 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-09-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-09-12 |
Time |
11:44 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-26 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-04-26 |
Time |
13:52 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-26 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-26 |
Time |
07:22 |
Sent To |
B |
|
| Notes |
| 2002-02-26 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | | | | 3)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTION PER 210-12 | | | | | | 4) NOTE: PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52. | | | MISSING DINING ROOM. | | | | | | 5)NOTE: PLEASE NOTE THAT GFI FOR A/C | | | COND UNIT IS SHOWN AS OPTIONAL? PLEASE | | | NOTE THAT THE GFI OUTLET IS REQ`D PER | | | MECH CODE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-12-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-12-26 |
Time |
10:39 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2002-12-26 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2002-12-26 00:00:00 | MECH REV PERMIT 02020086 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2002-02-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2002-02-23 |
Time |
10:13 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2002-02-23 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-07-16 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2002-07-16 |
Time |
13:34 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-07-16 00:00:00 | PLBG PLAN REVIEW REVISION, PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2002-06-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-20 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-20 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2002-06-20 00:00:00 | REVISION DENIED - FLOOR PLAN SHOWS A | | | SHOWER IN BATH #3, BUT SANT. RISER DIA- | | | GRAM SHOW NONE. PLEASE CLAIRFY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-05-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-05-02 |
Time |
13:00 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-05-02 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-04-26 |
Time |
13:52 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2002-02-09 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2002-02-09 00:00:00 | DENIED; | | | PAGE A-7. PLUMBING RISER NOT TO CODE. | | | UNVENTED FIXTURES AND MAJOR FIXTURES | | | OVER MINER FIXTURES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2002-05-06 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-05-06 |
Time |
19:58 |
Rev Time |
1.25 |
| Received By |
lhatten |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-07 00:00:00 | RESUB OKED ! BUT STILL NO ADDRESS FOR | | | HOUSE05/07/2002 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2002-04-03 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2002-04-03 |
Time |
21:33 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2002-03-09 |
Time |
21:31 |
Sent To |
|
|
| Notes |
| 2002-04-03 00:00:00 | REVIEW & STAMPED PLANS - PROVISO WINDOW | | | AND EXTERIOR DOORMUST BE SIGNED & | | | SEALED BY ARCHITECT IN SPACE PROVIDED | | | 03/09/2002 | | | PLAT NOT RECORDED YET ! |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-08 |
Time |
08:21 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|