Plan Review Details - Permit 02011590
Plan Review Stops For Permit 02011590
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-02-12 Cont ID  
Sent By btrobaug Date 2002-02-11 Time 10:30 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2002-02-12 00:00:00***************PROVISO***********
  
 POOL WILL BE INSPECTED ACCORDING TO THE
 FBC 2001 CHAPTER 424

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-02-11 Cont ID  
Sent By btrobaug Date 2002-02-11 Time 10:30 Rev Time 0.00
Received By btrobaug Date 2002-02-11 Time 10:30 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2002-03-26 Cont ID  
Sent By pschmitz Date 2002-03-26 Time 16:06 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-03-26 00:00:00REVISION, OK PES.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-03-08 Cont ID  
Sent By kstevens Date 2002-03-08 Time 09:13 Rev Time 0.50
Received By kstevens Date 2002-03-08 Time 09:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-03-06 Cont ID  
Sent By kstevens Date 2002-03-06 Time 16:52 Rev Time 1.00
Received By kstevens Date 2002-03-06 Time 16:51 Sent To  
Notes
2002-03-06 00:00:00DENIED
 REFERENCE: FBC-2001
  
 1) GENERAL NOTES #1 THE CURRENT CODE IS
 FBC-2001, SEC 424.2.6 ENGINEERING DESIGN
 NOT SBCCI-94 PBC SWIMMING POOL CODE.
 2) NOTE #5 DISPOSAL OF WATER. SEE FBC
 2001, SEC 424.2.10 WASTE WATER DISPOSAL.
 3) NOTE #7 WATER SUPPLY. SEE FBC 2001
 SEC 424.2.9 WATER SUPPLY, AND LOCAL ORD
 #2853-95 BACKFLOW PREVENTER REQUIRED ON
 WATER SERVICE.
 4) POOL, SPA SCHEMATIC NOT APPROVED.
 SPA MAIN DRAIN NOT SHOWN ON SCHEMATIC.
 INDICATE VENTS FOR MAIN DRAINS AND VAC
 LINE ON SCHEMATIC.
 5) FLA ENERGY CODE SEC 612.1ABC 2.3.2
 SPAS, HEATED POOLS SHALL BE EQUIPED WITH
 A COVER TO MINIMIZE HEAT LOSS.
 6) FBC-2001 SEC 424.2.13.2 JOINTS, CON-
 NECTIONS. PURPLE PRIMER REQUIRED ON PVC
 PIPING, FBC 2001 PLUMBING, SEC 605.21
 7) ANY CHANGES ON SIGNED AND SEALED
 PLANS SHALL BE REDRAWN, RESIGNED AND RE-
 SEALED, OR CHANGES SHALL BE INITIALED
 AND DATED BY ENGINEER OF RECORD.
 8) FBC 2001 SEC 424.2.6.6.2 SHOW DETAIL
 FOR TESTING AND ACCEPTING BY RECOGNIZED
 TESTING FACILITY FOR ALL SUCTION FITT-
 INGS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-02-28 Cont ID  
Sent By kstevens Date 2002-02-28 Time 19:10 Rev Time 1.25
Received By kstevens Date 2002-02-28 Time 19:10 Sent To  
Notes
2002-02-28 00:00:00DENIED
 REFERENCE: FLA. BLD. CODE - 2001 - POOLS
  
 1) 424.2.6.2 EQUIPMENT LIST WITH MFG.
 CUT SHEETS.
 2) 424.2.6.4 MORE MFG. INFO REQUIRED,
 GIVE MFG RECOMMENDATIONS PLUS LISTING
 AGENCY APPROVAL.
 3) 424.2.6.6.2 SHOW ANSI/ASME A112.19.8M
 SUCTION FITTINGS COVERS INFO FOR ACCEPT-
 ANCE.
 4) 424.2.6.6.3 VENT NOT SHOWN FOR SPA
 MAIN DRAIN OR VACUUM LINE. ARE #'S 1 OR
 2 BEING USED? PLEASE PROVIDE DETAILS.
 5) 424.6.6.5 6" TO 12" BELOW MIN WATER L
 LEVEL. SHOW DETAILS OR STATE ON PLANS.
 6) 424.2.14.2 WATER RETENTION, NOT ABLE
 TO RETAIN WATER IN HEATER WITH ONLY ONE
 VALVE LOCATED WHERE SHOWN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-09 Cont ID  
Sent By pschmitz Date 2002-02-09 Time 12:51 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2002-02-09 00:00:00DENIED, REVIWED FBC 2001, SEE ATTACHED
 SEC 424.2.6PAUL SCHMITZ

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-30 Cont ID  
Sent By sgraham Date 2002-01-30 Time 16:33 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***