| 2002-02-07 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |
| | |
| | NIETHER STANDARD BUILDING CODE 1997 OR |
| | FLORIDA BUILDING CODE 2001 ARE STATED ON |
| | THE PLANS.THE PLANS HAVE BEEN REVIEWED |
| | FOR COMPLIANCE WITH STANDARD BUILDING |
| | CODE 1997 AS PER TELEPHONE CONVERSATION |
| | WITH MPA ARCHITECTS', RICHARD LOGAN |
| | |
| | SBC = STANDARD BUILDING CODE 1997 |
| | SBC*= STANDARD BUILD'G CODE (CITY AMEND) |
| | |
| | 1) SBC* 104.1.1A SEPARATE PERMIT |
| | APPLICATION WILL BE REQUIRED FOR THE NEW |
| | CANOPY. |
| | |
| | 2) SBC 1012.4HORIZONTAL SLIDING DOORS |
| | IN A MEANS OF EGRESS.THE AUTOMATIC |
| | SLIDING ENTRANCE DOORS SHALL COMPLY WITH |
| | THE REQUIREMENTS, STATED IN THE CODE, |
| | FOR SLIDING DOORS IN A MEANS OF EGRESS. |
| | |
| | 3) SBC* 104.2STAIRCASE/ELEVATOR LOBBY. |
| | SUBMIT DETAILS TO DESCRIBE THE FINISHED |
| | FLOOR LEVELS, IN THIS AREA, FOLLOWING |
| | REMOVAL OF THE EXISTING RAMP BETWEEN THE |
| | STAIRCASE AND THE ELEVATOR LOBBY. |
| | |
| | 4) SBC* 1606.4 AND SBC 2405NEW STORE- |
| | FRONT.THE PLANS STATE THAT 1/4" THICK |
| | TEMPERED GLASS IS TO BE USED BUT, TO |
| | COMPLY WITH THE CONDITIONS OF THE |
| | PRODUCT APPROVAL, THE GLASS SHALL BE |
| | 9/16" THICK LAMINATED GLASS (0.09 INTER- |
| | LAYER BETWEEN TWO LAYERS OF 1/4" THICK |
| | HEAT STRENGTHENEND GLASS).AMEND THE |
| | PLANS TO AVOID CONFUSION. |
| | |
| | 5) SBC 2405SHEET A-6, DOOR SCHEDULE. |
| | ANY GLAZING IN DOORS, INLUDING THE |
| | ELEVATOR DOOR AND ADJACENT GLAZED PANEL, |
| | IS IN A 'HAZARDOUS LOCATION' AND IS |
| | REQUIRED TO BE SAFETY GLASS SATISFYING |
| | THE REQUIREMENTS OF THE CONSUMER PRODUCT |
| | SAFETY COMMISSION 16, CODE OF FEDERAL |
| | REGULATIONS, PART 1201 (CPSC 16-CFR, |
| | PART 1201).SUBMIT DETAILS TO |
| | DEMONSTRATE COMPLIANCE. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | IF YOU HAVE ANY QUERIES PLEASE CALL: |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |