Plan Review Details - Permit 02011043
Plan Review Stops For Permit 02011043
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-26 Cont ID  
Sent By btrobaug Date 2002-03-26 Time 18:03 Rev Time 0.00
Received By btrobaug Date 2002-03-26 Time 17:48 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-31 Cont ID  
Sent By btrobaug Date 2002-01-31 Time 11:13 Rev Time 0.00
Received By btrobaug Date 2002-01-31 Time 10:07 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-07-23 Cont ID  
Sent By pkrauss Date 2002-07-23 Time 07:45 Rev Time 0.30
Received By pkrauss Date 2002-07-23 Time 07:36 Sent To R
Notes
2002-07-23 00:00:00RESTAMP - MECHANICAL PERMIT 02011045
 SEE COMMMENTS FROM PREVIOUS REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-03-27 Cont ID  
Sent By pkrauss Date 2002-03-27 Time 15:25 Rev Time 0.35
Received By pkrauss Date 2002-03-27 Time 15:12 Sent To R
Notes
2002-03-27 00:00:00 
 PROVISO:
  
 PRIOR TO INSPECTION PLEASE PROVIDE
 MANUAL J CALCULATIONS TO MATCH ENERGY
 CALCULATIONS.PLANS & ENERGY CALCS
 COINCIDE BUT THE MANUAL J'S DO NOT.
  
 PLEASE NOTE, AREAS WITH 300 CFM OR
 GREATER REQUIRE RETURN AIR FROM THAT
 AREA.
  
 FOUR PLANS SUBMITTED WITH THIS
 RESUBMITTAL.PLEASE REMOVE OLD PLANS
 FROM APPROVED SET.
  
 THIS APPROVAL IS FOR THE HVAC ONLY.
 ADDITIONAL INFORMATION REQUIRED FOR THE
 FIRE PLACE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-02-04 Cont ID  
Sent By btrobaug Date 2002-03-26 Time 18:03 Rev Time 0.50
Received By hmoser Date 2002-02-04 Time 18:00 Sent To  
Notes
2002-02-04 00:00:00#1 ATTIC ACCESS MUST BE AS LARGE AS THE
 LARGEST PIECE OF THE EQUIPMENT AND IN NO
 CASE LESS THAN 22X36 INCHES.304.4
 #2 110-120 VOLT A/C GROUNDING TYPE
 CONVENIENCE OUTLET
 #3A LIGHT LOCATED ON THE SERVICE SIDE
 OF THE EQUIPMENT WHICH IS CONTROLLED
 BY A SWITCH LOCATED AT REQUIRED
 PASSAGEWAY OPENING SHALL BE PROVIED.
 304.4
 PLANREVIEW BY HAROLD MOSER
 [561]659-8096 EXT.8390
  
 PROVISO
 ENERGY CALCS NEED REVISED
 ALL THREE SYSTEMS MUST BE ON ENERGY CALC
 WITH SEER REATINGS BEFOR PERMIT IS
 ISSUED

Review Stop P PLUMBING
Rev No 1 Status P Date 2002-01-26 Cont ID  
Sent By jleech Date 2002-01-26 Time 13:42 Rev Time 0.33
Received By jleech Date 2002-01-26 Time 13:42 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2002-07-18 Cont ID  
Sent By pkrauss Date 2002-07-23 Time 07:47 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-18 00:00:00RESTAMP PLANS AND PRODUCT APPROVALS

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2002-04-24 Cont ID  
Sent By rmcdouga Date 2002-04-24 Time 10:24 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-04-24 00:00:00************BUILDING PROVISO************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) AN UPDATED SIGNED AND SEALED LETTER
 FROM THE USP ENGINEER ADDRESSING THE
 LOAD CAPACITIES OF THE TRUSS ANCHORS
 WHEN SPACED LESS THAN 8" APART.
  
 NOTE: A SEPARATE PERMIT IS REQUIRED FOR
 GAS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-04-03 Cont ID  
Sent By rmcdouga Date 2002-04-03 Time 11:18 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-04-03 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE AT LEAST ONE BATHROOM WITH A
 DOOR THAT HAS A 29 INCH CLEAR OPENING.
 BECAUSE A FULL BATH IS PROVIDED AT GRADE
 LEVEL, THE DOOR WITH A 29 INCH CLEAR
 OPENING IS REQUIRED ON A FULL BATH PER
 97 FLORIDA ACCESSIBILITY CODE.
  
 4) PROVIDE LISTING INFORMATION AND
 MANUFACTURERS SPECIFICATIONS FOR THE GAS
 GRILL LOCATED ON THE COVERED PORCH. THE
 INFORMATION SUBMITTED WAS FOR GAS LOGS.
 NOTE: A SEPARATE PERMIT IS REQUIRED FOR
 GAS.
  
 5) PROVIDE CONSTRUCTION DETAILS FOR THE
 ARCH OPENINGS IN THE EXTERIOR WALLS,
 WHERE WINDOWS AND DOORS ARE TO BE
 INSTALLED.
  
 6) CASEMENT (CSMT) WINDOWS ARE INDICATED
 ON SHEET A-3 AT THE LIBRARY TO COMPLY
 WITH EGRESS REQUIREMENTS, HOWEVER, THE
 ELEVATION ON SHEET A-4 INDICATES FIXED
 GLASS (F.G.)WINDOWS. PLEASE CORRECT.
  
 7) THE LETTER FROM THE USP ENGINEER IS
 REQUIRED TO BE AN ORIGINAL SIGNED,SEALED
 AND DATED BY THE ENGINEER. THE DATE ON
 THE LETTER SUBMITTED IS 4/17/01, WHICH
 IS ALMOST A YEAR OLD.
  
 8) INDICATE THE TYPE OF FASTENERS THAT
 WILL BE USED TO ATTACH THE STORM PANELS.
 PLEASE CIRCLE THE APPROPRIATE FASTENER
 ON THE PRODUCT APPROVAL.
  
 9)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - CASEMENT WINDOWS
  
 10) SEVERAL OF THE PRODUCT APPROVALS
 SUBMITTED ARE MISSING THE APPROVED
 DRAWINGS. PLEASE SUBMIT THE APPROVED
 DRAWINGS FOR THE FOLLOWING:
 LAWSON WINDOWS
 - SERIES 4000 CIRCLE TOP WINDOW
 - SERIES 6000 ALUMINUM FIXED WINDOW
 - SERIES SH-7500 SINGLE HUNG WINDOW
 - SERIES 8500 ALUMINUM HORIZONTAL
 SLIDING WINDOW
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-02-21 Cont ID  
Sent By pkrauss Date 2002-03-27 Time 15:35 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-02-21 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) NO FOUNDATION IS SHOWN ON A-2 FOR THE
 WING WALLS THAT EXTEND FROM THE GARAGE
 AT THE FRONT ELEVATION.
  
 4) THE DOTTED LINE INDICATING THE EDGE
 OF THE F3 FOOTING IS MISSING BETWEEN THE
 GARAGE AND BEDROOM #2. (A-2)
  
 5) THE STEEL COLUMNS AT THE FRONT ENTRY
 HAVE NO TAG MARK TO TIE THEM TO THE
 COLUMN SCHEDULE. (A-2)
  
 6) THE HEAD DETAIL FOR THE SLIDING GLASS
 DOOR BUCKS (A-7) DOES NOT INDICATE THE
 FASTNERS, SPACING, ETC. FOR ATTACHING
 THE 1X4 BUCK.
  
 7) PROVIDE AT LEAST ONE FULL BATHROOM
 WITH A DOOR THAT HAS A 29 INCH CLEAR
 OPENING.
  
 8) SAFETY GLASS IS REQUIRED IN THE
 WINDOW OF BED ROOM #4 THAT IS WITHIN 2'
 OF THE BATHROOM DOOR. 97SBC 2405.2.1 (3)
  
 9) THE ATTIC ACCESS OPENINGS SHALL NOT
 BE LESS THAN 22"X 36" PER 97SBC 2309.6.
  
 10) PROVIDE LISTING INFORMATION AND
 MANUFACTURERS SPECIFICATIONS FOR THE
 GAS GRILL. A SEPARATE PERMIT IS REQUIRED
 FOR GAS.
  
 11) PROVIDE FRAMING DETAILS FOR ARCH
 OPENINGS.
  
 12) INDICATE ROOF NAILING SCHEDULE THAT
 COMPLIES WITH THE CITY OF WPB AMENDMENTS
 TO THE 97SBC. 8D COMMOMON NAILS 6" O.C.
 AT EDGES AND INTERMEDIATE FOR ZONES 1 &
 2 AND 4" O.C. AT EDGES AND 6" O.C.
 INTERMEDIATE FOR ZONE 3.
  
 13) EGRESS WINDOW IS REQUIRED IN THE
 LIBRARY, WHICH COULD BE USED AS A
 SLEEPING ROOM. 97SBC 1005.4
  
 14) THE TRUSS ANCHOR SCHEDULE ON A-6
 STATES THAT TAPR222 WITH 10-10D NAILS IS
 RATED FOR 1485# OF UPLIFT. HOWEVER,THE
 2001 USP CATALOG REQUIRES 14-10D NAILS.
 PLEASE CORRECT.
  
 15) PROVIDE A LETTER FROM USP FOR
 INSTALLATION OF TRUSS CONNECTORS STRAPS
 SPACED CLOSER THAN 8" INDICATING THE
 REDUCED LOAD VALUES.
  
 16) THE USP CATALOG DOES NOT LIST AN
 RT24. PLEASE CLARIFY. RT20,RT24F AND
 RT24T ARE LISTED.
  
 17) THE PLATE TO STUD CONNECTORS FOR THE
 INTERIOR BEARING PARTITIONS ON DETAIL C
 ON A-9 ARE GIVEN AS (USP) TPP. THESE ARE
 MENDING PLATES IN THE USP CATALOG AND
 NOT INTENDED FOR STRUCTURAL USE. PLEASE
 INDICATE APPROPRIATE CONNECTORS, SUCH AS
 USP SPT66 OR TP6X.
  
 18) WALL SECTION 1 ON A-7 SHOULD
 INDICATE THAT THE BOTTOM OF THE FOOTING
 SHALL BE A MINIMUM OF 12" BELOW GRADE
 AND THE FINISH FLOOR SHALL BE A MINIMUM
 OF 4" ABOVE FINISH GRADE. 97SBC 1804.1.3
 & CITY OF WPB AMENDMENTS 1804.1.9.
  
 19)PLEASE INDICATE (CIRCLE) ON THE
 PRODUCT APPROVAL THE TYPE OF
 FASTENERS THAT WILL BE USED TO ATTACH
 STORM PANELS.
  
 20) THE PRODUCT EVALUATION FROM SBCCI
 # 9652 HAS BEEN REPLACED BY # 9652A. THE
 16' X 8' GARAGE DOOR THAT IS INDICATED
 ON THE EVALUATION THAT WAS REPLACED IS
 NO LONGER LISTED ON THE UPDATED REPORT.
 PLEASE INDICATE WHICH DOOR WILL BE USED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-24 Cont ID  
Sent By sgraham Date 2002-01-24 Time 11:21 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***