Plan Review Details - Permit 02010360
Plan Review Stops For Permit 02010360
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-02-27 Cont ID  
Sent By rbrown Date 2002-02-27 Time 14:43 Rev Time 0.00
Received By rbrown Date 2002-02-27 Time 14:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-12 Cont ID  
Sent By rbrown Date 2002-02-12 Time 19:46 Rev Time 0.00
Received By rbrown Date 2002-02-12 Time 19:46 Sent To  
Notes
2002-02-12 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 --PROVISO--
 A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-01-17 Cont ID  
Sent By rbrown Date 2002-01-17 Time 19:15 Rev Time 0.00
Received By rbrown Date 2002-01-17 Time 19:15 Sent To  
Notes
2002-01-17 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE
 SBC*= STANDARD BUILD'G CODE (AMENDMENTS)
 FL ACC CODE = FLORIDA ACCESSIBILITY CODE
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SBC 2405.2.1(3)GLAZING IN HAZARDOUS
 LOCATIONS.THE GLAZING IN THE WALL
 ADJACENT THE DOOR TO OFFICE-2 IS IN A
 HAZARDOUS LOCATION.SUBMIT DETAILS TO
 DEMONSTRATE COMPLIANCE WITH SBC 2405.1
  
 3) FL ACC CODE 4.1.6(1)(B) AND 4.1.3(10)
 AN ACCESSIBLE DRINKING FOUNTAIN IS
 REQUIRED IN THE NEW TENANT AREA.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-01 Cont ID  
Sent By dpalmer Date 2002-02-01 Time 07:05 Rev Time 0.00
Received By dpalmer Date 2002-02-01 Time 07:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-01-14 Cont ID  
Sent By dpalmer Date 2002-01-14 Time 20:00 Rev Time 0.00
Received By dpalmer Date 2002-01-14 Time 20:00 Sent To  
Notes
2002-01-14 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW ALL CONTINUOUS AT
 125%. (LIGHTING ETC)
  
 3) PLEASE CLARIFY EQUIPMENT GROUNDING
 METHOD BETWEEN FIRST MEANS OF DISCONNECT
 AND PANEL(S). EQUIPMENT GROUNDING
 CONDUCTORS ARE TO BE SIZED BY 250-122.
  
 4)NOTE: PLEASE CLARIFY EXISITNG LIGHTING
 EMERGENCY LTS/EXITS LTS ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICALPLANREVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-02-27 Cont ID  
Sent By rbrown Date 2002-02-27 Time 14:42 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-02-26 Cont ID  
Sent By mcarsill Date 2002-02-26 Time 11:46 Rev Time 0.00
Received By mcarsill Date 2002-02-26 Time 11:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2002-02-01 Cont ID  
Sent By mcarsill Date 2002-02-01 Time 13:53 Rev Time 0.00
Received By mcarsill Date 2002-02-01 Time 13:53 Sent To  
Notes
2002-02-01 00:00:00AGAIN NO FIRE SPRINKLER DRAWINGS
 PROVIDED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-01-09 Cont ID  
Sent By mcarsill Date 2002-01-09 Time 15:37 Rev Time 0.00
Received By mcarsill Date 2002-01-09 Time 15:37 Sent To  
Notes
2002-01-09 00:00:001) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2002-01-12 Cont ID  
Sent By pkrauss Date 2002-01-12 Time 06:12 Rev Time 0.40
Received By pkrauss Date 2002-01-12 Time 05:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-02-11 Cont ID  
Sent By kstevens Date 2002-02-11 Time 18:00 Rev Time 0.00
Received By kstevens Date 2002-02-11 Time 18:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By pschmitz Date 2002-01-15 Time 11:50 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-01-15 00:00:00PLUMBING PLAN REVIEW, DENIED
 SHT 2-5
 (1A) COMPLY WITH MIN FACILITIES SPC-94,
 TAB 407, WOMEN'S REST RM. 2-W/C, 2-LAVS.
 ALSO 1 DRINKING FOUNTAIN REQUIRED.
 (B) LOUNGE SINK TO COMPLY W/ FACBC-97
 SEC 4.24.1, HEIGTH, CLEAR FLOOR SPACE.
 (2) WATER HEATER,SHALL BE READLY ACCESS-
 IBLE SEC-501.
 SHT 1-5
 (3) PLUMBING ISOMETRIC, MENS REST ROOM
 W/C NOT VENTED.
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop Z ZONING
Rev No 1 Status N Date 2002-02-27 Cont ID  
Sent By rbrown Date 2002-02-27 Time 14:54 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
***NONE***