Plan Review Details - Permit 02010316
Plan Review Stops For Permit 02010316
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-05-07 Cont ID  
Sent By rbrown Date 2002-05-07 Time 13:31 Rev Time 0.00
Received By rbrown Date 2002-05-07 Time 13:31 Sent To  
Notes
2002-05-07 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
  
 --PROVISO--
 IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, PLANS STAMPED BY THEM AND A COPY
 OF THE RECEIPT SUBMITTED TO CITY OF WEST
 PALM BEACH BUILDING DEPARTMENT, BEFORE
 A BUILDING PERMIT CAN BE ISSUED.
  
 --PROVISO--
 SBC* 1707.4PRODUCT APPROVAL.THE
 SUBMITTED DRAWING SHEETS 1 THRO' 4 OF 4
 ATTACHED TO THE NOTICE OF ACCEPTANCE
 NO. 01-0629.08 FOR THE ALUMINUM SINGLE
 HUNG WINDOW ARE COPIES OF A FAX AND ARE
 NOT LEGIBLE.SUBMIT LEGIBLE COPIES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-04-15 Cont ID  
Sent By kstevens Date 2002-05-07 Time 07:51 Rev Time 0.00
Received By rbrown Date 2002-04-15 Time 10:30 Sent To  
Notes
2002-04-15 00:00:00BUILDING PLAN REVIEW
 ******PROVISO*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
  
 --PROVISO--
 IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, PLANS STAMPED BY THEM AND A COPY
 OF THE RECEIPT SUBMITTED TO CITY OF WEST
 PALM BEACH BUILDING DEPARTMENT, BEFORE
 A BUILDING PERMIT CAN BE ISSUED.
  
 --PROVISO--
 SBC 1506.1SEPARATE ROOFING PERMIT
 (#02010321).SUBMIT A PRODUCT APPROVAL
 FOR THE FIBERGLASS SHINGLE ROOF COVERING
  
 --PROVISO--
 SBC* 1707.4PRODUCT APPROVAL.THE
 SUBMITTED NOTICE OF ACCEPTANCE
 NO. 01-0516.10 FOR THE ALUMINUM SINGLE
 HUNG WINDOW IS MISSING DRAWING SHEET
 1 OF 8.SUBMIT DRAWING SHEET 1.
  
 --PROVISO--
 SBC 2309.6ACCESS TO ATTIC SPACE.
 TAKING INTO ACCOUNT THE POSITION AND
 SIZE OF THE NEW AIR HANDLING UNIT AND
 WATER HEATER, ATTIC ACCESS NOT LESS THAN
 22"X36" SHALL BE PROVIDED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-01-24 Cont ID  
Sent By dpalmer Date 2002-01-14 Time 19:39 Rev Time 0.00
Received By rbrown Date 2002-01-24 Time 14:59 Sent To  
Notes
2002-01-24 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FL ENERGY CODE = FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILD'G CONSTR'N
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SBC* 1707.4PRODUCT APPROVALS.THE
 SUBMITTED PRODUCT APPROVALS DO NOT HAVE
 VALID EXPIRATION DATES.
  
 4) SHEET 2, ROOF FRAMING PLAN.CLARIFY
 DORMER ROOF FRAMING.THE DORMER DETAIL
 SHOWS 2'X8" RAFTERS AT 16 O/C WHILST
 PLAN SHOWS TRUSSES.TRUSS DRAWINGS,
 INCLUDING GIRDER TRUSSES, SHALL BE
 SUBMITTED.
  
 5) SHEET 2, FLOOR FRAMING PLAN.WHERE
 THE EXISTING STAIR OPENING IS TO BE
 FILLED IN, THE PROPOSED 'SIMPSON WS28'
 IS NOT A VALID SIMPSON CONNECTOR
 REFERENCE. PROVIDE CORRECT REFERENCE.
  
 6) SBC 1015.3GUARDRAIL RAILINGS SHALL
 BE SPACED TO REJECT THE PASSAGE OF A 4"
 DIAMETER SPHERE.ADD NOTES TO ENSURE
 COMPLIANCE.
  
 7) SBC 1005.4EMERGENCY EGRESS WINDOW.
 THE SILL HEIGHT OF THE OPENING SHALL NOT
 BE GREATER THAN 44" ABOVE THE FLOOR AND
 THE CLEAR OPENING SHALL BE MINIMUM OF
 24" HIGH AND 20" WIDE.ADD THE REQUIRED
 HEIGHT INFORMATION TO THE PLANS.
  
 8) FL ENERGY CODE 103.0COMPLIANCE
 SHALL BE DEMONSTRATED BY SUBMITTAL OF
 APPROPRIATE ENERGY CODE COMPLIANCE FORMS
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-04-29 Cont ID  
Sent By dpalmer Date 2002-04-29 Time 14:06 Rev Time 0.00
Received By dpalmer Date 2002-04-29 Time 14:05 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-04-03 Cont ID  
Sent By dpalmer Date 2002-04-03 Time 06:27 Rev Time 0.00
Received By dpalmer Date 2002-04-03 Time 06:27 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-14 Cont ID  
Sent By pkrauss Date 2002-01-14 Time 08:23 Rev Time 0.00
Received By dpalmer Date 2002-01-14 Time 19:39 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-05-06 Cont ID  
Sent By pkrauss Date 2002-05-06 Time 10:03 Rev Time 0.30
Received By pkrauss Date 2002-05-06 Time 10:03 Sent To P
Notes
2002-05-06 00:00:00MECHANICAL PERMIT REQUIRED

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-04-01 Cont ID  
Sent By dpalmer Date 2002-04-29 Time 16:03 Rev Time 0.30
Received By pkrauss Date 2002-04-01 Time 16:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-01-14 Cont ID  
Sent By pkrauss Date 2002-01-14 Time 08:20 Rev Time 0.35
Received By pkrauss Date 2002-01-14 Time 08:14 Sent To E
Notes
2002-01-14 00:00:00 
 MECHANICAL PLANS NOT SUBMITTED WITH
 PERMIT APPLICATION FOR REVIEW.PLEASE
 PROVIDE PLANS WITH MECHANICAL PERMIT
 APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-05-07 Cont ID  
Sent By kstevens Date 2002-05-07 Time 07:51 Rev Time 0.00
Received By kstevens Date 2002-05-07 Time 07:51 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-04-11 Cont ID  
Sent By pkrauss Date 2002-05-06 Time 10:06 Rev Time 0.00
Received By kstevens Date 2002-04-11 Time 12:33 Sent To  
Notes
2002-04-11 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) RISER DIAGRAM NOT TO CODE. 2ND FLOOR
 BATHROOM SHALL NOT WASH PAST WASH MACH-
 INE AND LAUNDRY SINK. SEPARATE STACK OR
 TIE INTO STACK BELOW W/M & LAUNDRY SINK.
  
 2) HEATER PAN REQUIRED FOR HEATER IN
 ATTIC. 1" DRAIN LINE SHALL BE REQUIRED
 TO BE PIPED OUTSIDE AND TERMINATE 6"
 ABOVE GRADE. SEC 507.8.2
  
 3) EVERY ATTIC SPACE IN WHICH MECHANICAL
 EQUIPMENT IS INSTALLED SHALL HAVE AN
 OPENING AS LARGE AS THE LARGEST PIECE OF
 EQUIPMENT. 22"X36" MIN. EVERY PASSAGEWAY
 SHALL BE UNOBSTRUCTED AND SHALL HAVE
 SOLID CONTINUOUS FLOORING NOT LESS THAN
 24" WIDE FROM OPENING TO EQUIPMENT. ON
 THE CONTROL SIDE AND OTHER SIDES WHERE
 ACCESS IS NECESSARY FOR SERVICING THE
 EQUIPMENT, A LEVEL WORKING PLATFORM EX-
 TENDING A MINIMUM OF 30 FROM THE EDGE OF
 THE EQUIPMENT WITH A 36" HIGH CLEAR
 WORKING SPACE SHALL BE PROVIDED. SECTION
 304.5.2 SMC-97
  
 4) MODEL COUNTYWIDE AMENDMENTS SEC 304.4
 ATTIC INSTALLATION, ALL AIR CONDITIONING
 AND HEATING EQUIPMENT INSTALLED IN AN
 ATTIC SHALL HAVE AN ACCESSIBLE DISCONNE-
 CT SWITCH AND A 110-120 VOLT A/C GROUND-
 ING TYPE CONVENIENCE OUTLET CONVENIENT
 TO THE GENERAL EQUIPMENT AREA. IN AN
 ATTIC, A LIGHT LOCATED ON THE SERVICE
 SIDE OF THE EQUIPMENT WICH IS CONTROLLED
 BY A SWITCH LOCATED AT THE REQUIRED PASS
 AGEWAY OPENING SHALL BE PROVIDED.
  
 5) APPLIANCES INSTALLED IN ATTIC SPACES
 SHALL BE SUPPORTED FROM THE TOP CHORDS
 OF TRUSSED OR ROOF FRAMING OR AS DE-
 SIGNED BY A PROFESSIONAL ENGINEER.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status N Date 2002-01-13 Cont ID  
Sent By pschmitz Date 2002-01-13 Time 10:04 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-01-13 00:00:00PROVISO: REVISON OF ISOMETRIC COMPLYING
 WITH SPC-94 BEFORE 1ST ROUGH. PES

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-09 Cont ID  
Sent By sgraham Date 2002-01-09 Time 16:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***