| Plan Review Stops For Permit 02010292 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-02-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-02-13 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-02-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-02-07 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-07 00:00:00 | THE FOLLOWING ITEMS THAT WERE NOTED IN | | | THE JANUARY 25, 2002 COMMENTS HAVE NOT | | | BEEN ADDRESSED. | | | | | | THE POOL DESIGN STANDARD IS NOT SHOWN. | | | NSPI - 5. | | | | | | THE ENTRAPMENT AVOIDANCE DEVICE(S) ARE | | | NOT SHOWN FOR THE VACUUM FITTING OR | | | THE SECONDARY BACKUP SYSTEM AS REQUIRED | | | BY FBC 424.2.6.6.3. | | | | | | THE EQUIPMENT FOUNDATION IS SHOWN | | | WITHOUT DIMENSIONS.SEE FBC 424.2.22. | | | | | | THE SWIMMING POOL BARRIER AS SHOWN ON | | | THE PERIMETER OF THE PROPERTY DOES NOT | | | PREVENT ACCESS TO THE POOL FROM THOSE | | | ON THE PROPERTY AS IS THE INTENT OF THE | | | CODE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-01-25 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2002-01-25 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2002-02-01 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2002-01-25 00:00:00 | PERMITS FOR SWIMMING POOLS APPLIED FOR | | | ON OR AFTER JANUARY 1, 2002 MUST COMPLY | | | WITH SECTION 424 OF THE 2001 FLORIDA | | | BUILDING CODE. (FBC) | | | | | | SHOW THAT THE DESIGN, TOGETHER WITH ANY | | | NECESSARY NOTATIONS, ENSURE THAT THE | | | CONSTRUCTION AND WORKMANSHIP WILL | | | COMPLYWITH ANSI/NSPI-5.SEE FBC | | | 424.2.6. | | | | | | PROVIDE THE INFORMATION AND | | | SPECIFICATIONS FOR THE PROPOSED HEATER. | | | | | | NOTE A POOL COVER IS REQUIRED BY SEC | | | 612.1.ABC.2.3.2 OF THE FLORIDA ENERGY | | | CODE.PLEASE INDICATE INTENTION OF | | | COMPLIANCE ON PLANS. | | | | | | SHOW THE METHOD OF ENTRAPMENT AVOIDANCE | | | FOR THE VALVED VACUUM FITTING AND THE | | | BACK UP SYSTEM IN ACCORDANCE WITH FBC | | | 424.2.6.6.3. | | | | | | NOTE THE INSTALLATION DEPTH OF THE | | | VACUUM FITTING IN ACCORDANCE WITH FBC | | | 424.2.6.6.5. | | | | | | SHOW THE LOCATION OF THE PUMP AND | | | EQUIPMENT FOUNDATION.SEE FBC 424.2.22. | | | | | | CLEARLY SHOW THE METHOD OF SWIMMING | | | POOL ENCLOSURE - BARRIER AS PROVIDED | | | FOR IN FBC 424.2.17. | | | | | | EXCERPTS FROM THE FBC ARE ATTACHED FOR Y | | | OUR USE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-01-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-01-22 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-02-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-01 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-02-01 |
Time |
07:08 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-01-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-01-22 |
Time |
11:56 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2002-01-22 |
Time |
11:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-01-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-01-15 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-01-15 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2002-01-15 00:00:00 | ****************UNSAT!****************** | | | | | | 1) PLEASE SUBMIT ELECTRICAL LOAD | | | CALCULATIONS WHEN INSTALLING POOL | | | HEATERS. | | | 2) SHOW POOLHEATER WIRING. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | (561 659-8096 EXT.8392 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-02-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-02-06 |
Time |
17:52 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2002-02-06 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2002-02-06 00:00:00 | BACKFLOW REQUIRED ON WATER SERVICE. | | | PLAN REVIEWED TO FBC-2001 KSTEVENS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2002-01-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-01 |
Time |
07:29 |
Rev Time |
0.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-01-14 00:00:00 | PROVISO: BACK FLOW PREVENTER ON WATER | | | SERVICE.PES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-01-10 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-01-10 |
Time |
11:49 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|