| Plan Review Stops For Permit 01121737 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-01-23 |
Time |
14:06 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2003-01-23 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2003-01-23 00:00:00 | 01-23-03 PRODUCT APPROVAL SKYLIGHT / | | | WITH LARGE MISSLE IMPACTJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2003-01-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-23 |
Time |
10:31 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-13 00:00:00 | REVISION DATED 12-22-02 STAIR SHOP | | | DRAWINGS OKJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2003-01-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-10 |
Time |
16:37 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-09 00:00:00 | REV 01-07-03 OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2002-12-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-08 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2002-12-31 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2002-12-31 00:00:00 | SHOP DRAWINGS :GUARDRAILS/ HANDRAILS | | | SEE FL ACCESSIBILITY CODE: 4.9.4(2) | | | SEE PAGE 2 SECTION 2 THERE IS NO EXTEN- | | | SION ATTHE BOTTOM OF STAIR. | | | AT THE TOP, THE EXTENSION SHALL BE | | | PARALLEL WITH THE FLOOR AT LEAST 12" | | | BEYOND THE TOP RISER, AT THE BOTTOM THE | | | HANDRAIL SHALL CONTINUE THE SLOPE FOR A | | | DISTANCE OF THE WIDTH OF 1 TREAD FROM | | | THE RISER, THE REMAINDER OF THE EXTEN- | | | SION SHALL BE HORIZONTAL (12"). | | | BUILDING PLAN REVIEW | | | JIM WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2002-12-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-12-31 |
Time |
15:19 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-12-31 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2002-12-31 00:00:00 | REVISION DATED 12/23/02 ACCESS TO ELEC | | | ROOM OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-12-11 |
Time |
15:17 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-12-31 00:00:00 | REVISIONS: DELETE CORRIDOR FIRST FLOOR | | | RECONFIGURE 2ND FLOOR. OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2002-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-31 |
Time |
10:53 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
2002-12-11 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2002-12-11 00:00:00 | BUILDING PLAN REVIEW | | | REVISION DATED: 11-15-02REVIEWED | | | PERMIT: 01121737 | | | ADD: 707 N DIXIE | | | CONT: GSP & ASSOCIATES | | | TEL: (561)722-3301 | | | SBC = 1997 STANDARD BUILDING CODE | | | | | | 1) SUITE 102/104 DELETION OF CORRIDOR. | | | BUILDING PLAN REVIEW | | | J WITMER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-04-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-26 |
Time |
18:02 |
Rev Time |
1.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-01 00:00:00 | PROVISO: | | | 1) PLANS TO BE REVIEWED BY COUNTY FOR | | | ASSESSMENT FOR IMPACT FEES! BEFORE | | | ISSUANCE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-01-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-01-15 |
Time |
09:12 |
Rev Time |
4.50 |
| Received By |
jwitmer |
Date |
2002-01-15 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2002-01-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01121737 | | | 711 N DIXIE | | | CONT: GSP & ASSOCIATES | | | TEL: (561) 697-8444 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS STANDARD BUILDING CODE | | | FL ACC CODE= FLORIDA ACCESSIBILITY CODE | | | 1997 EDITION | | | | | | 1)- SBC* 104.2.2 ADDITONAL INFORMATION | | | REQUIRED. BETWEEN THE SITE PLAN & ARCH. | | | PLANS PATH OF TRAVEL FOR HANDICAPPED IS | | | UNCLEAR FOR ENTRY RAMP. | | | | | | 2)- PLEASE INDICATE WHAT TYPE OF BUILD- | | | ING DESIGN WAS USED IN THE DESIGN? | | | PLANS INDICATE A EXISTING FIRE RISER, IS | | | THIS TO BE CONSIDERED A FIRE SPRINKLERED | | | BUILDING? IF SO,ADDITIONAL INFORMATIOIN | | | WILL BE REQUIRED TO DO A COMPETENT PLAN | | | REVIEW. THIS PLAN REVIEW WAS COMPLETED | | | AS A WORSE CASE, NO FIRE SPRINKLERS | | | SINCE THE REQUIRED INFORMATION WAS LACK- | | | ING. | | | | | | 3)- SBC (FIRE DISTRICT) 102.1 TYPES OF | | | CONSTRUCTION PRMITTED. TYPE I,II,III, | | | IV OR V ARE PERMITTED IN FIRE DISTRICT. | | | | | | 4)- BALCONY INDICATES USE OF WOOD ON THE | | | EXTERIOR WALLS. | | | | | | 5)-SBC FI02.2.5 ALL WALLS, FLOORS, | | | ROOFS, & THEIR SUPPORTING STRUCTURAL | | | MEMBERS SHALL PROVIDE NOT LESS THAN | | | 1-HR FIRE RESISTANCE. | | | | | | 6)- SBC TABLE 600 INDICATE COMPLIANCE | | | WITH TYPE V BUILDING 0'-3' FROM PROPERTY | | | LINE 3 HR EXTERIOR WALLS. | | | | | | 7)- SURVEY INDICATES THE FRONT ENTRY | | | PROJECTING 1'-0" INTO THE PUBLIC PROPER- | | | TY AT GRADE ? | | | | | | 8)- BALCONY CORBELS, WHAT TYPE OF MATER- | | | IAL, HOW WILL IT BE ATTACHED? | | | | | | 9)- F 102.2.7 ARCH. TRIM APPROVED NON- | | | COMBUSTIBLE TRIM SHOW COMPLIANCE REPORT | | | FOR NONCOMBUSTIBLES, (EXPANDED POLYSTI- | | | RENE SYSTEMS). | | | | | | 10)- ENERGY CALS W/ MANUAL "J" | | | | | | 11)- SHEET A101, SHOW DOORWAYS INTO | | | TENANT SPACE. SBC1001.1.2.IN EVERY BUILD | | | ING HEREAFTER ERECTED, MEANS OF EGRESS | | | SHALL COMPLY WITH THE MINIMUM REQUIRE- | | | MENTS OF THIS CHAPTER. THE PLANS DO NOT | | | INDICATE EGRESS FROM TENANT SPACE OR | | | COMMON ELEMENTS AS RESTROOMS. | | | | | | 12)- SECOND FLOOR EGRESS, SBC 1020.1- | | | SINGLE EGRESS REQUIREMENTS > 3500 SQ FT, | | | DO NOT MEET REQUIREMENTS, 1004.2.2 REQUI | | | RES A MINIMUM OF 2 MEANS OF EGRESS ARE | | | REQUIRED. | | | | | | 13)- SHEET 101/201 SBC 1004.1.4. WHERE | | | 2 OR MORE EXITS OR EXIT ACCESS DOORS | | | SHALL BE PLACED A DISTANCE APART EQUAL | | | TO NOT LESS THAN ONE HALF OF THE LENGTH | | | OF THE MAXIMUM OVERALL DIAGONAL DIMEN- | | | SION OF THE BUILDING OR AREA TO BE | | | SERVED. | | | | | | 14)- EXITS, SPIRAL STAIRS, SBC 1006.1.1. | | | EXIT STAIRWAYS BETWEEN FLOORS SHALL BE | | | ENCLOSED IN OR SEPERATED BY FIRE RESIS- | | | TANT CONSTRUCTION IN ACCORDANCE WITH | | | 705.2 & TABLE 705.1.2.PRPOTECTION OF | | | FLOOR OPENINGS. | | | | | | 15)- SBC 704.2.4. EXIT ACCESS CORRIDORS: | | | FIRE EXIT RATINGS SHALL BE IN ACCORDANCE | | | WITH TABLE 704.2.3.2. | | | | | | 16)- SBC 705.1.1.FIRE RATED ASSEMBLIES | | | SHOW COMPLIANCE EITHER UL LISTING OR GYP | | | SUM ASSOC NUMBER. | | | | | | 17)- SBC 705.5.1.2. FIRESTOP SYSTEMS, | | | LIST PRODUCTS ,CUT SHEETS. | | | | | | 18)- SPIRAL STAIRS: SBC SHOW HOW ONCE | | | YOU LEAVE THE STAIR ENCLOSURE FOR SPIRAL | | | STAIRS COMPLIANCE FOR EXIT PASSAGEWAYS | | | SBC 1010.3. | | | | | | 19)- 1004.3.1 ACCESSIBLE MEANS OF EGRESS | | | WHERE MORE THAN 1 MEANS OF EGRESS IS RE- | | | QUIRED FROM ANY REQUIRED ACCESSIBLE | | | SPACE, EACH ACCESSIBLE PORTION OF SPACE | | | SHALL BE SERVED BY NOT LESS THAN 2A | | | CCESSIBLE MEANS OF EGRESS. | | | 1004.3.2.1. TO BE AN ACCESSIBLE MEANS OF | | | EGRESS SHALL HAVE A CLEAR WIDTH OF 48" | | | BETWEEN THE HANDRAILS AND INCORPARATE | | | AN AREA OF REFUGE WITHIN AN ENLARGED | | | STORY LEVEL LANDING OR SHALL BE ACCESSED | | | FROM EITHER AN AREA OF REFUGE COMPLYING | | | WITH 1004.3.5 OR A HORIZONTAL EXIT. | | | | | | 20)- SHEET A.104 SHOW COMPLIANCE WITH | | | SECTION 1007.5.5.12" HANDRAIL EXTENTIONS | | | | | | 21)- SHEET A-105 SEC 2: GUARDRAILS SEE | | | 1015.3 FOR 4" SPHERE (BALCONY), ALSO | | | SHEET A104 SEC BB GAURDRAIL 2" SPHERE | | | AT NEW GUARDRAIL. | | | | | | 22)-SBC 1606.2.6.2 COMPONENTS & CLADDING | | | PROVIDE (2 COPIES) OF PRODUCT APPROVAL | | | REPORTS FOR ALL GLAZED OPENINGS, WINDOWS | | | DOORS & SKYLIGHTS. DOORS WITH NO GLAZING | | | (EXTERIOR) SHALL ALSO BE REQUIRED TO SUB | | | MIT PRODUCT TESTING REPORTS. | | | | | | 23)- MISSING WINDOW & DOOR BUCK ATTACH- | | | MENT. | | | | | | 24)- PROVIDE INFORMATION ON NEW ROOF | | | ACCESS ? | | | | | | 25)- UNCLEAR AS TO WHAT IS GOING TO | | | HAPPEN AT EXISTING SKYLIGHT? IS THE SKY- | | | LIGHT BEING USED FOR THIS PURPOSE? | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-01-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-08 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2003-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-07 |
Time |
14:00 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-01-07 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-04-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-04-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-04-08 |
Time |
12:57 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2002-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-03-25 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-03-25 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2002-03-25 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT ONLY THE | | | ELECTRICAL RISER DIAGRAM IS STILL | | | SUBMITTED? PLEASE CLARIFY WHERE SHELL | | | ELECTRICAL IS SHOWN? | | | | | | 2)NOTE: PLEASE NOTE THAT NOTE#1 FROM | | | FIRST REVIEW STILL NEEDS TO BE ADDRESSED | | | PLEASE NOTE LOAD CALCUALTIONS NEED TO | | | BE SHOWN. WATTS PER SQ FT ETC. | | | NEC ART 220. | | | | | | PLEASE NOTE FIRE REVIEW NOTES FOR EM LTS | | | AND EXIT LTS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMAITON FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-01-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-08 |
Time |
07:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-08 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2002-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE NOTE LOAD CALACULATIONS | | | NEED TO BE SHOWN. 215-5,220-3,220-10, | | | 220-11,220-13 ETC. PLEASE ALSO NOTE | | | THAT ALL CONTINUOUS LOADS NEED TO BE | | | SHOWN AT 125%. 230-42,215-3. | | | | | | 2)NOTE: PLEASE NOTE THAT TOTAL EXCEEDS | | | RATING OF SERIVCE ENTRANCE CONDUCTORS | | | 310-16. | | | ALSO NOTE OCP IS NOT LARGE ENOUGH FOR | | | LOAD SHOWN. | | | | | | 3)NOTE: PLEASE CLARIFY METHOD OF EQUIP- | | | -MENT GROUNDING BETWEEN DISCONNECT AND | | | UNIT PANELS. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 5)NOTE: PLEASE PROVIDE SIZING OF GUTTER. | | | 374 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2002-04-03 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-04-03 |
Time |
16:53 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-04-03 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2002-04-03 00:00:00 | N/A | | | THIS PEMITT IS FOR SHELL ONLY, WILL | | | APPLY FOR SITE/CIVIL SEPARATLY. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2002-03-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-27 |
Time |
09:41 |
Rev Time |
3.00 |
| Received By |
mamini |
Date |
2002-03-27 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2002-03-27 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE STORM WATER CALC. | | | FOR OUR REVIEW AND APPROVAL. | | | 2. PLEASE PROVIDE PERVIOUS & IMPERVIOUS | | | CALC. FOR ENTIRE SITE. | | | 3. PLEASE NOTE THAT, ALL DRIVEWAY | | | APPROACHES MUST BE AT MIN. PER CITY OF | | | WPB STANDARD AND REQUIREMENTS.SEE | | | ATTACHED. | | | 4. PLEASE PROVIDE DETAILS FOR THE | | | PROPOSED DUMPSTER ENCLOSURE.IT SHOULD | | | BE CONSTRUCTED PER CITY'S REQUIREMENT IF | | | GARBAGE IS TO BE PICKED UP BY THE CITY. | | | SEE ATTACHED. | | | 5. IS THERE ANY NEW SEWER CONNECTIONS? | | | 6. PLEASE INCLUDE POLLUTION PREVENTION | | | PLAN (NOTES, DETAILS).IT SHOULD BE | | | INSTALLED IN THE FIELD PROIR TO ANY | | | EARTH WORKS. | | | 7. ALL CONNECTIONS TO THE CITY OF WPB | | | SERVICES AND BACKFLOW PREVENTERS MUST BE | | | APPROVED AND INSPECTED BY THE CITY | | | OFFICIALS, 659-8040. | | | 8. A SEPARATE PERMIT APPLICATION AND | | | FEES FOR UNDRGROUND UTILITIES/SITE WORKS | | | IS REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-01-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-02 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-02 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-04-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-04-09 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-04-09 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2002-04-09 00:00:00 | ELECTRICAL PLANS FOR SHELL ONLY. | | | | | | A) THE FIRE SPRINKLER SYSTEM IS TO BE | | | MONITORED BY LICENSED UL LISTED CENTRAL | | | STATION APPROVED BY THE FIRE DEPARTMENT. | | | B) ADDITIONAL EXIT SIGNS AND EMERGENCY | | | LIGHTING EQUIPMENT WILL BE REQUIRED | | | FOR THE FUTURE TENANT SPACES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-04-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-01-07 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2002-01-07 00:00:00 | 1) PLEASE BE ADVISED THAT THE BUILDING | | | IS LOCATED WITHIN THE CITY FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY. | | | 2) BUILDING ADDRESS REQUIRED PER CITY | | | CODE 3343-00. | | | 3) NO INDICATIONS ON PLANS REGARDING | | | THE RATINGS ON THE PROPOSED TENANT WALLS | | | 4) NO ILLUMINATED EXIT SIGNS OR | | | EMERGENCY LIGHTING SHOWN ON THE PLANS. | | | 5) NO INTERIOR FINISH CLASSIFICATION | | | INFORMATION ON PLANS FOR THE WALLS | | | AND CEILINGS. | | | 6) THE PLANS INDICATE AN EXISTING FIRE | | | SPRINKLER RISER, HOWEVER NO FIRE | | | SPRINKLER WERE SUBMITTED WITH THE | | | DRAWINGS. IT IS BELIEVED THAT THE | | | FIRE SPRINKLER SYSTEM IS OF AN OLDER | | | TYPE AND THE PRESENT CONDITION OF IT | | | IS UNKNOWN. | | | 7) NO EXIT DOORS SHOWN FROM TENANT | | | SPACE. | | | 8) PLEASE EXPLAIN HOW EXITING OCCURS | | | FROM THE BUILDING. PLEASE EXPLAIN | | | RATIONALE FOR EXITING. | | | 9) WHAT WILL THE CURVED STAIR TO BE | | | USED FOR. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-23 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-23 |
Time |
10:31 |
Sent To |
B |
|
| Notes |
| 2003-01-23 00:00:00 | TO JIM WITMERS DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-15 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-15 |
Time |
13:22 |
Sent To |
B |
|
| Notes |
| 2003-01-15 00:00:00 | TO JIM WITMER'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-01-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-10 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-10 |
Time |
16:37 |
Sent To |
B |
|
| Notes |
| 2003-01-10 00:00:00 | TO JIM W./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2002-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-31 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-31 |
Time |
10:52 |
Sent To |
B |
|
| Notes |
| 2002-12-31 00:00:00 | TI JIM WITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2002-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-12-31 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-12-31 |
Time |
10:49 |
Sent To |
B |
|
| Notes |
| 2002-12-31 00:00:00 | TO JIM WITMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-11-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-11-26 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-11-26 |
Time |
18:02 |
Sent To |
B |
|
| Notes |
| 2002-11-26 00:00:00 | TO JIM W./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-04-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-01 |
Time |
10:19 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-04-01 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2002-04-01 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-05 |
Time |
10:14 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-01-05 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2002-01-05 00:00:00 | | | | | | | NO MECHANICAL PLANS SUBMTTED FOR REVIEW. | | | PLEASE PROVIDE MECHANICAL PLANS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2002-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-04-23 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-04-23 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2002-04-23 00:00:00 | THIS PERMIT FOR SHELL ONLY - ROOF DRAIN | | | CALCULATIONS FOR PRIMARY AND SECONDARY | | | DRAINS SUBMITTED, BUT FOR 1997 SPC NOT | | | 1994. CALCULATIONS WORK FOR EITHER CODE, | | | PIPE SIZE IS SUFFICIENT. REQUEST REVIS- | | | IONS FOR CALCULATIONS UNDER PROPER CODE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-04-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-04-12 |
Time |
23:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-04-12 |
Time |
23:58 |
Sent To |
|
|
| Notes |
| 2002-04-13 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SUBMIT CALCULATIONS FOR MINIMUM FAC- | | | ILITIES PER SPC-94 TABLE 407 AND SECTION | | | 407.1.3. DRINKING FOUNTAINS REQUIRED | | | | | | 2) SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS. INCLUDE ALL AREA | | | OF ROOFS THAT MAY DRAIN TO ROOF FROM | | | ABOVE AND 1/2 AREA OF ALL VERTICAL WALLS | | | PER SPC-94 SEC 1108 AND 1109. | | | | | | 3) SUBMIT A SANITARY RISER DIAGRAM. | | | | | | 4) SUBMIT A WATER RISER DIAGRAM. | | | | | | 5) SUBMIT A STORM RISER DIAGRAM. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2002-01-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-01-16 |
Time |
19:32 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2002-01-16 |
Time |
19:32 |
Sent To |
|
|
| Notes |
| 2002-01-16 00:00:00 | NO PLUMBING SHOWN; | | | 94 SPC 401.2.2 ALL BUILDINGS INTENDED | | | FOR HUMAN OCCUPANCY SHALL ADEQUATE | | | SANITARY FACILITIES. | | | SHOW WATER AND STORM DIAGRAMS AND | | | INFORMATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-03-14 |
Time |
10:38 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2002-01-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-01-04 |
Time |
15:11 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|