Plan Review Details - Permit 01121705
| Plan Review Stops For Permit 01121705 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-01-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-05 |
Time |
07:02 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-01-09 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01121705 | | | 828 W LAKEWOOD RD | | | O/B LAZO, CARDID | | | TEL: 963-0357 | | | | | | SBC= 1997 STANDARD BUILDING CODE | | | SBC*= AMENDMENTS/ STANDARD BUILDING CODE | | | | | | 1)- SBC 104.2.1 SEE ATTACHMENT FOR QAULI | | | TY OF PLANS. | | | 2)- ATTACHED ARE SOME PRESCRIPTIVE RE- | | | QUIREMENTS FOR DESIGN. PLANS SHALL RE- | | | FLECT THIS ADDITIONAL INFORMATION. | | | STRUCTURAL PLANS WILL INDICATE THE | | | FOLLOWING: | | | FLOOR PLAN, | | | WALL ELEVATIONS INDICATE THE WINDOW | | | SIZES, WALL FINISHES, | | | WALL SECTIONS SEE ATTACHMENT, HEADER | | | SIZES, ANCHOR AND STRAPPING REQUIREMENT | | | 3)- SBC 1814.2.4 WALL & FLOOR JOINTS AND | | | PENETRATIONS SHALL BE MADE WATERTIGHT | | | USING APPROVED METHODS ANS MATERIALS. | | | 4)- 2304.2.5. CLEARENCE BETWEEN WOOD | | | SIDING, SHEATHING SHALL BE NOT LESS THAN | | | 6" ABOVE THE NATURAL GRADE. | | | 5)- OWNER WILL TAKE THE PLANS TO THE | | | COUNTY FOR IMPACT FEE ASSESSMENT. | | | 6)- PRODUCT APPROVAL REPORTS REQUIRE | | | 2 COPIES. | | | 7)- THE WINDOW REPORT SUBMITTED HAS NOT | | | BEEN TESTED FOR LARGE MISSLE IMPACT | | | RESISTANCE, STORM SHUTTERS SHALL BE REQU | | | IRED SUBMIT 2 COPIES OF PRODUCT TESTING | | | REPORTS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096X8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2001-12-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2001-12-28 |
Time |
16:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2001-12-28 |
Time |
16:26 |
Sent To |
B |
|
| Notes |
| 2001-12-28 00:00:00 | CAN'T REVIEW,NO ELECTRICAL PLANS WITH AP | | | PLICATION.PLEASE RESUBMIT WITH DRAWINGS | | | TO COMPLY WITH ALL NEC.AND LOCAL CODES. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | (561) 659-8096 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-05 |
Time |
07:01 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2002-01-05 |
Time |
07:00 |
Sent To |
B |
|
| Notes |
| 2002-01-05 00:00:00 | | | | NO MECHANICAL PLANS SUBMITTED WITH THIS | | | PERMIT APPLICATION.PLEASE PROVIDE | | | PLANS WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2002-01-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-01-05 |
Time |
06:45 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2002-01-05 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2002-01-05 00:00:00 | NO PLUMBING SHOWN ON DRAWINGS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-28 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-12-28 |
Time |
09:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|