Plan Review Details - Permit 01121692
Plan Review Stops For Permit 01121692
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-02-06 Cont ID  
Sent By hpiskura Date 2002-02-06 Time 11:38 Rev Time 0.00
Received By hpiskura Date 2002-02-04 Time 16:03 Sent To  
Notes
2002-02-07 00:00:00THIS BUILDING WILL BE A THRESHOLD
 BUILDING AS DEFINED IN F.S. 553 AND
 WILL REQUIRE A THRESHOLD INSPECTION
 PLAN AND A THRESHOLD INSPECTOR.
 CONTACT DON NEELY, ASSISTANT BUILDING
 OFFICIAL, FOR MORE INFORMATION.
 561-659-8096 X 8219.
  
 BEFORE A PERMIT TO CONSTRUCT MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY FOR THE CITY, THE
 PERMIT PLANS STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED
 TO THE PERMIT APPLICATION.
  
 AT TIME OF PERMIT APPLICATION THE
 FOLLOWING ITEMS MUST ACCOMPANY THE
 APPLICATION: (THREE COPIES OF EACH FOR
 THRESHOLD BUILDINGS)
  
 A RECENT SIGNED AND SEALED PROPERTY
 SURVEY.
  
 ENERGY CODE CALCULATIONS
  
 THREE COMPLETE SETS OF WORKING DRAWINGS
  
 CODE COMPLIANCE NOTES:
  
 THE TOWER/CUPOLA MUST COMPLY WITH SBC
 1517.5.1.2.1. SINCE PORTIONS OF IT WILL
 BE MORE THAN 25' ABOVE THE ROOF AND
 PORTIONS IN CROSS SECTION WILL EXCEED
 200 SQUARE FEET. EITHER OF THE
 CONDITIONS REQUIRE COMPLIANCE WITH THE
 CODE SECTION.
  
 SHEET A7.1, PROVIDE DETAILS OF
 CONSTRUCTION FOR THE METAL STUD FRAMING
 INCLUDING CONNECTIONS.SEE SBC 104.2.
  
 SHEET A8.1 SECTION (3), THE VENTED
 SCREED IS SHOWN ON THE BOTTOM OF THE
 SUB-FASCIA, HOW IS THIS FUNCTIONAL?
  
 SHEET A8.1 SECTION (1) THE GABLE END IS
 SHOWN AS TYPE VI CONSTRUCTION. (WOOD)
 SBC TABLE 600 TYPE V CONSTRUCTION IS
 REQUIRED TO BE NON-COMBUSTIBLE.SEE
 TABLE 600 TITLE LINES "EXTERIOR
 BEARING, (AND NON-BEARING) WALLS AND
 GABLE ENDS OF ROOF."
  
 PROVIDE A CEILING CONSTRUCTION DETAIL
 FOR THE CUPOLA.SBC 104.2.
  
 NOTE THAT THIS IS A "PLAN REVIEW" AND
 NOT A PERMIT APPLICATION.PERMIT
 APPLICATIONS RECEIVED ON OR AFTER MARCH
 1, 2002 WILL BE SUBJECT TO REVIEW FOR
 CONFORMANCE WITH THE 2001 FLORIDA
 BUILDING CODE WHICH MAY HAVE DIFFERENT
 REQUIREMENTS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-01-25 Cont ID  
Sent By dpalmer Date 2002-01-25 Time 09:45 Rev Time 0.00
Received By dpalmer Date 2002-01-25 Time 06:53 Sent To  
Notes
2002-01-25 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PLANS ARE
 SHOWING A "FUTURE" GENERATOR. PLEASE
 CLARFIY PLANS ARE SHOWING A EMER DIST
 SYSTEM AT THIS TIME. PLEASE CLARFIY
 IF EM LTS AND EXIT LTS ARE ARE BATTERY
 BACK UP, PLEASE SHOW ON FIXTURE SCHEDULE
 .700-12
  
 2)NOTE: PLEASE NOTE SPACING FOR GEN.
 DISC. REQ`D TO BE GROUPED WITH MAINS
 PER 230-72 ALSO PLEASE NOTE 230-76&79
 FOR DISCONNECT REQ`MENTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVEIW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-01-14 Cont ID  
Sent By mamini Date 2002-01-14 Time 14:09 Rev Time 0.00
Received By mamini Date 2002-01-14 Time 14:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-01-15 Cont ID  
Sent By mcarsill Date 2002-01-15 Time 12:58 Rev Time 0.00
Received By mcarsill Date 2002-01-15 Time 12:58 Sent To  
Notes
2002-01-15 00:00:001) SITE PLAN DOES NOT INDICATE FIRE
 HYDRANT LOCATIONS, FIRE MAINS, ETC.
 2) HOW IS FIRE RESCUE EXPECTED TO
 ENTER THE GUARD HOUSE. WILL IT BE
 STAFFED FULL TIME OR PART TIME.
 3) BUILDING ADDRESS REQUIRED ON
 BUILDING.
 4) PANIC HARDWARE REQUIRED ON EXIT
 DOORS.
 5) PROVISIONS ARE TO BE MADE FOR AT
 LEAST TWO HANDICAPPED PERSONS.
 6) NO HYDRAULIC CALCULATIONS PROVIDED
 WITH FIRE SPRINKLER PLANS.
 7) SEPARATE PLANS AND PERMITS REQUIRED
 FOR FUTURE GENERATOR INSTALLATION.
 8) PROVIDE PRODUCT APPROVALS FOR FIRE
 SHUTTER BETWEEN DINING 141 AND SERVICE
 142.
 9) SEPARATE PLANS AND PERMITS REQUIRED
 FOR HOOD,DUCT AND EXTINGUISHING SYSTEM.
 10) PLEASE PROVIDE INTERIOR FINISH
 INFORMATION.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2002-01-28 Cont ID  
Sent By pkrauss Date 2002-01-28 Time 08:46 Rev Time 4.00
Received By pkrauss Date 2002-01-28 Time 07:48 Sent To  
Notes
2002-01-28 00:00:00********************DENIED**************
  
  
 1.PLAN SHEET M1 INDICATES TYPE "B"
 FLUE VENT PLEASE PROVIDE DETAIL OF
 FLUE VENT PENETRATION THROUGH THE
 ROOF.
  
 2.PROVIDE CALCULATION FOR COMBUSTION
 AIR IN THE MECHANICAL ROOM.
  
 3.PROVIDE DETAIL FOR THE "SHAFT" FLUE
 DUCT.
  
 4.PLEASE PROVIDE MANUFACTURER
 SUBMTTIAL DATA FOR THE METALBESTOS
 FLUE DUCT.
  
 5.PLAN SHEET M2 ON THE HOOD DETAIL
 INDICATES 3" LIMITED COMBUSTIBLES &
 12" TO COMBUSTIBLES.AS PER 1997
 SMC 504.4, HOOD SHALL HAVE A MINIMUM
 CLEARANCE OF 18" FROM COMBUSTIBLE
 CONSTRUCTION & MAY BE REDUCED TO NOT
 LESS THAN 3" WHERE THE COMBUSTIBLE
 MATERIAL PROTECTED WITH MATERIALS AS
 APPROVED FOR 1 HR FIRE RESISTANCE.
  
 PLEASE NOTE ADDITIONAL PERMITS
 REQUIRED FOR HOOD, FIRE SUPRESSION &
 WALKIN COOLERS/FREEZERS.PROVIDE
 PLANS & MANUFACTURER SUBMTTAL DATA
 WITH PERMIT APPLICATION.
  
 6.PLEASE INDICATE SIZE, TERMINATION &
 MATERIAL OF FLUE DUCT FOR THE FIRE
 PLACE.
  
 7.PROVIDE AIR BALANCE SCHEDULE SHOWING
 COMPLIANCE WITH 1997 SMC 501.2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-01-26 Cont ID  
Sent By kstevens Date 2002-01-26 Time 13:35 Rev Time 0.00
Received By kstevens Date 2002-01-26 Time 13:35 Sent To  
Notes
2002-01-26 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) PLEASE ROUTE PLANS TO DEPT OF BUSIN-
 ESS REGULATION HOTEL & RESTURANT DIV.
 FOR REVIEW AND COMMENTS BEFORE RESUBMIT-
 ING FOR PLAN REVIEW.
 2) SHT P2, PLEASE CONTACT RODNEY COMPO
 ENVIRONMENTAL COMPLIANCE (561) 837-4074
 FOR GREASE TRAP SIZE. WASTE ORD. #2938-
 96. SUBMIT REVIEW LETTER BEFORE RESUBMIT
 ING FOR PLAN REVIEW,
 3) PLEASE SUBMIT CALCULATIONS FOR MINIM-
 UM FACILITIES PER SPC TABLE 407 AND SEC
 407.1.3. SHOW DEDUCTED AREAS.
 4) PLEASE PROVIDE A WATER RISER DIAGRAM.
 SHOW PIPE SIZES, WATER HAMMER ARRESTORS
 LOCATION OF BACKFLOW PREVENTERS ECT.
 REDUCED PRESSURE BACKFLOW REQUIRED ON
 WATER SERVICE TO CLUBHOUSE.
 5) STORM RISER DIAGRAM REQUIRED. INCLUDE
 PIPE SIZES AND SQ FT ADDED FROM EACH
 DOWNSPOUT AND TRENCH DRAIN.
 6) SHT A2.1 & SHT P2, STAFF TOILET ROOM
 #149B, DOOR SHALL NOT SWING INTO CLEAR
 FLOOR SPACE OF LAV. FACBC SEC 4.22.2
 7) SHT A5.4 DETAIL #8 STAFF SINK TO
 COMPLY WITH FACBC SEC 4.24. SHOW DETAILS
 FOR ALL SUBSECTIONS.
 8) SHT A5.3 RM #129 DETAIL #1 HAIRCARE
 VACUUM BREAKER REQUIRED ON WATER SUPPLY
 6" ABOVE FLOOD RIM LEVEL.
 9) SHT A2.1 & P1 FOUNTAIN, PLUMBING
 CONTRACTOR TO SUPPLY VALVE AND BACKFLOW
 FOR FOUNTAIN CONTRACTOR TO TIE INTO.
 10) SHTS P2/P3 #40 DISHWASHER, TIE INTO
 SANITARY NOT GREASE PER UTILITY DEPT.
 11) SHTS P2/P3 WITH DISHWASHER MOVED TO
 SANITARY A VENT IS REQUIRED IN GREASE
 LINE BEFORE THE LAST FLOOR DRAINS BY
 DISHWASHER AREA.
 12) SHTS P2/P3 2" VENT FROM GREASE TRAP
 NOT REQUIRED AND DOES NOT MEET CODE FOR
 HORIZONTAL DRY VENTS PLEASE REMOVE. SPC
 SEC 708.1
 13) SHT P2 PLEASE SUPPLY MANUFACTURE
 INFO FOR WATER FILTER #6. FILTER SHALL
 BE NSF APPROVED.
 14) SHT P2 PER MODEL COUNTYWIDE AMEND-
 MENTS TO SPC-94 SEC 607.7, ONLY 2 FIX-
 TURES ON 1/2" COLD WATER SUPPLY. (SEE
 ITEMS #'S 23/21 AND SINK P6 WITH GLASS
 FILLER.
 15) SHTS P2/P3/P4 ALL INDIRECT WASTE
 SHALL BE DRAINED TO FLOOR SINK NOT TO
 FLOOR DRAINS. SEE F.D. BY WALK IN COOLER
 AND WATER HEATER DETAIL (P-12) F.D.
 SPC SEC 804.5
 16) SHTS P1/P2/P3 FLOOR DRAINS ARE REQ-
 UIRED IN STAFF TOILET ROOM #149B AND
 IN GANG BATH RM'S #109 & #115. SEC 409.4
 17) SHTS P2/P3 SINK P-6 AT GLASS FILLER
 STATION NOT VENTED PROPERLY.
 18) SHT P3 SANITARY RISER DIAGRAM, VENT
 FOR 3-COMP. SINK DISPOSERS #35 & #41, &
 HAND SINK #26 NOT VENTED THROUGH THE
 ROOF AS REQUIRED.
 19) SHTS P2/P3 2-WAY CLEAN OUT IS REQ-
 UIRED NEAR JUNCTION OF BLDG. DRAIN AND
 BLDG SEWER FOR GREASE LINE. SEC 710.2.2
 20) SHT P4, GREASE TRAP DETAIL NOT APP-
 ROVED. PLEASE SEE ATTACHED SHEET WITH
 APPROVED GREASE TRAP DETAIL FROM WPB
 UTILITY DEPT.
 21) SEPARATE GREASE TRAP PERMIT REQUIRED
 PERMIT TO BE APPLIED FOR BY PROVIDER OF
 GREASE TRAP NOT PLUMBING CONTRACTOR.
 22) SEPARATE GAS PERMIT REQUIRED. SEE
 ATTACHED GAS PERMIT REQUIREMENT SHEET.
 NOTE NUMBERS 1, 3, 6, 7, 8, 9, 10, 11, &
 12 CIRCLED. INFORMATION REQUIRED FOR ALL
 CIRCLED NUMBERS FOR PLAN REVIEW.
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER STANDARD
 GAS CODE.
 3. TYPE OF GAS, (LP OR NATURAL)
 6. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER THE STANDARD GAS
 7. INDICATE THE DELIVERY PRESSURE (PSI)
 PER STANDARD GAS CODE SEC. 305.2. IF
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 CODE SECS. 402.4 THRU 402.4.4.7. NO 7"WC
 8. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER THE STANDARD GAS CODE SECS
 602 THRU 612.
 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 STANDARD GAS CODE SEC. 402.
 10. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 11. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 12. EMERGENCY HOOD SHUT DOWN SHUT OFF
 VALVE TO BE BELOW CEILING. MANUAL SHUT
 OFF VALVE TO BE UPSTREAM. UNION TO BE
 DOWN STREAM OF MANUAL VALVE.
 23) SHTS A2.1/A2.4 PLEASE SHOW CLEAR
 FLOOR SPACE FOR ALL ACCESSIBLE FIXTURES.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***