Plan Review Details - Permit 01121619
Plan Review Stops For Permit 01121619
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-07-15 Cont ID  
Sent By rmcdouga Date 2002-07-15 Time 09:38 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-07-10 Cont ID  
Sent By rmcdouga Date 2002-07-10 Time 16:48 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-10 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) PRODUCT APPROVALS FROM TWO DIFFERENT
 STORM PANEL COMPANIES WERE SUBMITTED.
 PLEASE INDICATE WHICH ONE YOU WILL BE
 USING AND REMOVE THE OTHER. NOTE THE
 PRODUCT APPROVAL FOR THE EASTERN METAL
 SUPPLY STORM PANELS ARE NOT COMPLETE.
  
 3) INDICATE THE INSTALLATION OPTIONS
 THAT WILL BE USED BY CIRCLING THEM ON
 THE PRODUCT APPROVAL DRAWINGS.
  
 4) TAPCONS ARE NOT AN ACCEPTABLE ANCHOR
 FOR ATTACHMENT TO WOOD FRAME
 INSTALLATIONS. SEE SHEET 6 OF THE TOWN &
 COUNTRY PRODUCT APPROVAL.
  
 5) THE INSTALLATION SCHEDULE IS NOT
 FILLED OUT CORRECTLY. PLEASE REVISE.
 - THE SHUTTER HEIGHT WILL BE A MINIMUM
 OF 1-1/2" LARGER THAN THE OPENING DUE TO
 THE 3/4" EDGE DISTANCE REQUIREMENT FOR
 FASTENERS.SEE SHEET 6.
 - THE SHUTTER SPAN IS THE OPENING
 DIMENSION PARALLEL TO THE DIRECTION THE
 SHUTTER IS MOUNTED.
 - NO STORM BARS ARE REQUIRED FOR THE
 SPANS INDICATED.
 - NO HEADER REINFORCEMENT OR STORM PANEL
 BOLTING WILL BE REQUIRED.
 TYPICALLY EACH WINDOW OPENING IS GIVEN A
 NUMBER AND EACH NUMBER IS LISTED IN THE
 SCHEDULE ALONG WITH THE INFORMATION FOR
 THAT OPENING. DOUBLE WINDOWS ARE LISTED
 AS ONE OPENING. I HAVE ATTACHED A COPY
 OF A KEY PLAN AND SCHEDULE FOR YOU TO
 USE AS A GUIDE.
  
 6) THE PRODUCT APPROVALS FOR THE WINDOW
 MULLIONS ARE NOT COMPLETE AND THE
 DRAWINGS ARE ILLEGIBLE. TWO COPIES ARE
 REQUIRED.
  
 7) IF YOU DO NOT WANT THE ELECTRICAL
 PERMIT AT THIS TIME, PLEASE INDICATE ON
 REQUEST FOR PROPOSAL (WORK DESCRIPTION)
 THAT ITEM #3 WILL BE APPLIED FOR UNDER A
 SEPARATE PERMIT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-01-07 Cont ID  
Sent By rmcdouga Date 2002-01-07 Time 12:57 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-01-07 00:00:00*************BUILDING UNSAT*************
  
 1) PROVIDE A KEY PLAN INDICATING THE
 WINDOWS THAT ARE BEING REPLACED. IF THE
 BEDROOM WINDOWS ARE REPLACED, THE NEW
 WINDOWS MUST COMPLY WITH SECTION 1005.4
 FOR EMERGENCY EGRESS REQUIREMENTS.
 SAFETY GLAZING IS REQUIRED IN WINDOWS
 THAT ARE IN HAZARDOUS LOCATIONS PER 97
 SBC SEC. 2405.2.
  
 2) PROVIDE PRODUCT APPROVALS FOR
 STRUCTURAL MULLIONS IF ANY WINDOWS ARE
 JOINED TOGETHER.
  
 3) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.SEE ATTACHED
 ONLY PART OF THE PRODUCT APPROVALS (THE
 THE APPROVED DRAWINGS) FOR THE STORM
 PANELS WERE SUBMITTED.
  
 PLEASE CALL IF YOU HAVE ANY QUESTIONS.
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2002-07-10 Cont ID  
Sent By btrobaug Date 2002-07-10 Time 11:39 Rev Time 0.00
Received By btrobaug Date 2002-07-10 Time 11:39 Sent To R
Notes
2002-07-10 00:00:00THERE ARE STILL NO ELECTRICAL PLANS WITH
 THIS APPLICATION.PLEASE RESUBMIT
 WITH SAME FOR REVIEW.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 561/659-8096 EXT. 8392

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-01-07 Cont ID  
Sent By btrobaug Date 2002-01-07 Time 11:37 Rev Time 0.00
Received By btrobaug Date 2002-01-07 Time 11:36 Sent To  
Notes
2001-12-28 00:00:00THERE ARE NO ELECTRICAL PLANS WITH THIS
 APPLICATION.PLEASE RESUBMIT WITH SAME.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 (561) 659-8096