| Plan Review Stops For Permit 01121474 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2002-06-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-12 |
Time |
13:44 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-05-30 00:00:00 | BUILDING PROVISO | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT SHOP DRAWINGS FOR GUARDRAILS | | | AT SECOND FLOOR COVERED PORCHES FOR | | | APPROVAL PRIOR TO INSTALLATION. | | | | | | 4) PROVIDE INSTALLATION SCHEDULE FOR | | | THE STORM PANELS THAT WILL BE USED ON | | | THE FIRST FLOOR. | | | | | | 5)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - STRUCTURAL MULLIONS THAT CAN BE | | | INSTALLED AS PART OF AN IMPACT | | | RESISTANT UNIT. | | | - IMPACT RESISTANT SLIDING GLASS DOORS | | | | | | 6) SITE SPECIFIC ENGINEERING (PRODUCT | | | APPROVAL) REQUIRES THE WET SIGNATURE, | | | DATE AND EMBOSSED SEAL OF THE ENGINEER | | | CERTIFYING THE PRODUCT AND OF THE DESIGN | | | PROFESSIONAL OF RECORD. PLEASE SUBMIT | | | ORIGINAL SIGNED AND SEALED DOCUMENTS FOR | | | THE IMPACT RESISTANT SLIDING GLASS DOORS | | | OR SBCCI/METRO-DADE PRODUCT APPROVALS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2002-04-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-04-15 |
Time |
14:25 |
Rev Time |
3.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-15 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT SHOP DRAWINGS FOR GUARDRAIL AT | | | 2ND FLOOR COVERED PORCH FOR APPROVAL | | | PRIOR TO INSTALLATION. | | | | | | 4)THE REAR ELEVATION SHOWS THE 2ND FLOOR | | | GUARDRAIL WITH A 4" SPACE BETWEEN THE | | | BOTTOM RAIL AND THE FLOOR. THE CODE | | | REQUIRES THAT THE BOTTOM RAIL REJECT THE | | | PASSAGE OF A 2" SPHERE. PLEASE CORRECT. | | | | | | 5) SECTION B-B ON SHEET A7 SHOWS A 9.5" | | | TREAD EXCLUSIVE OF THE NOSING WITH A | | | 7.37" RISER AND THE STAIR DETAIL (1/A7) | | | NOTES 10"TREAD EXCLUSIVE OF NOSING WITH | | | A 7.22" RISER. PLEASE CORRECT. | | | | | | 6) THE FRONT ELEVATION ON A5 NOTES A | | | CEMENTITOUS FINISH OVER CONCRETE BLOCK | | | CONSTRUCTION AT THE EXTERIOR WALL OF THE | | | 2ND FLOOR BEDROOM #3, WHICH IS WOOD | | | FRAME. PLEASE CORRECT AND INDICATE THE | | | EXTERIOR FINISH THAT WILL BE APPLIED TO | | | THIS WALL. (WIRE LATH AND STUCCO?) | | | | | | 7) INDICATE FIREBLOCKING WHERE THE WOOD | | | EXTERIOR WALL AND CEILING INTERSECT AT | | | THE GABLE END OF 2ND FLOOR BEDROOM #3 ON | | | SECTION A-A ON SHEET A7. | | | INDICATE THAT THE GABLE ENDWALL WILL | | | BE BALLOON FRAMED TO THE VAULTED CEILING | | | DIAPHRAM. | | | | | | 8) SHEET A1 IS MISSING THE FOOTING | | | DESIGNATIONS. THE COLUMN AND FOOTING | | | MARKS THAT TIE TO THE SCHEDULES ARE ALSO | | | MISSING. PLEASE CORRECT. | | | | | | 9) PROVIDE (2) PRODUCT APPROVALS, KEY | | | PLANS AND INSTALLATION SCHEDULES | | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | | TO BE USED FOR STORM PANELS. | | | IMPACT GLAZING OR PERMANENTLY AFFIXED | | | PROTECTIVE DEVICES ARE REQUIRED ABOVE | | | THE FIRST LEVEL. PERMANENTLY AFFIXED | | | PROTECTIVE DEVICES REQUIRE THE WRITTEN | | | APPROVAL OF THE BUILDING OFFICIAL. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-03-22 |
Time |
17:00 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-03-22 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) SAME COMMENTS AS 01121475. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-02-08 |
Time |
14:16 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-08 00:00:00 | *************BUILDING UNSAT************* | | | | | | SAME COMMENTS AS PERMIT # 01121475. | | | | | | TRUSSES DENIED | | | SAME COMMENTS AS PERMIT # 01121475. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2002-12-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-20 |
Time |
10:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2002-12-20 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-03-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-03-15 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-03-15 |
Time |
16:37 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2002-02-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-02-05 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-02-05 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2002-02-05 00:00:00 | *******************UNSAT!*************** | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATION AND RESUBMIT. | | | | | | 1) A.I.C. RATING AT FIRST MEANS OF | | | DISCONNECT,ALL UNITS. | | | | | | 2) "A" & "B" UNITS CONFORM TO 230-3. | | | | | | 3) BATH ROOMS TO COMPLY WITH | | | 210-52D.INCLUDE SAME IN PANEL SCHEDULES | | | AND LOAD CALCULATIONS. | | | | | | 4) GROUND LEVEL UNITS COMPLY WITH | | | 210-52E. | | | | | | 5)CONDENSING UNITS GFCI,210-63 NEC & | | | 309.2 MECH. | | | | | | 6)UNIT "D" BED ROOMS 2&3 AND UNIT "C" | | | BED ROOM #3 TO COMPLY WITH NFPA-72 | | | 2-2.1.1.1. | | | | | | 7) ALL WIRING TO CONFORM TO THE FAIR | | | HOUSING ACT,CHAPTER#524 CFR 100-205. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 | | | EXT.8392 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-02-08 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2002-03-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-03-20 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-03-20 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2002-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-03-15 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-06 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2002-02-06 00:00:00 | 1) BUILDING ADDRESSES REQUIRED. | | | 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING AND AFTER CONSTRUCTION. | | | 3) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | 4) ELECTRIC POWERED SMOKE DETECTORS ARE | | | REQUIRED. | | | 5) PLEASE INDENTIFY ALL EGRESS WINDOWS | | | ON THE PLANS AND MAXIMUM SILL HEIGHTS. | | | 6) PLEASE INDENTIFY INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | 7) THE C LABELED FIRE DOORS ARE REQUIRED | | | TO BE EQUIPPED WITH SELF-CLOSING | | | DEVICES. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-12-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-12-12 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-12-12 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
| 2002-12-12 00:00:00 | ROB M./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2002-04-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-04-18 |
Time |
09:38 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2002-04-18 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2002-04-18 00:00:00 | 1997 SMC - BUILDING #4 | | | MECHANICAL PERMIT 02041143 | | | | | | MANUFACTURER SUBMITTAL DATA FOR THE | | | DRYERS SUBMITTED. | | | | | | SEE ALSO A-3 FOR ADDITIONAL MECHANICAL | | | NOTES. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2002-02-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-05 |
Time |
08:52 |
Rev Time |
1.20 |
| Received By |
pkrauss |
Date |
2002-02-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2002-02-05 00:00:00 | | | | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PLEASE PROVIDE THE FOLLOWING | | | INFORMATION WITH MECHANICAL PLANS AND | | | PERMIT. | | | | | | 1.DUCT LAYOUT - SIZE, MATERIAL, R - | | | VALUE, AND CFM DISTRIBUTION. | | | | | | 2.PROVIDE GRILLE SIZE. | | | | | | 3.HVAC EQUIPMENT SCHEDULE - MAKE, | | | MODEL, BTU, KW HEAT STRIP AND SEER | | | OF THE CONDENSER. | | | | | | 4.INDICATE SIZE OF THE REFRIGERATION | | | AND CONDENSATE LINES.PROVIDE | | | PIPING LAYOUT FROM AHU TO CONDENSER. | | | | | | 5.CONDENSATE FROM UNITS LARGER THAN | | | 3 TON SHALL TERMINATE INTO AN | | | APPROVED DRYWELL OR STORM DRAIN. | | | | | | 6.PROVIDE DETAIL OF DRYER EXHAUST. | | | INDICATE TERMINATION (ROOF OR WALL), | | | ARE DUCTS IN A FIRE RATED CHASE? | | | PLEASE NOTE AS PER 1997 SMC 509.3, | | | MINIMUM SIZE 4" WITH A MAXIMUM | | | LENGTH OF 25' (5' REDUCTION FOR EACH | | | 90 DEGREE BEND & 2 1/2 REDUCTION FOR | | | EACH 45 DEGREE BEND).WALL OR ROOF | | | CAP SHALL BE NON SCREENED WITH A | | | BACKDRAFT DAMPER. | | | | | | 7.BATHROOM EXHAUST - INDICATE DUCT | | | SIZE, MATERIAL, AND TERMINATION. | | | | | | ALL ENVIRONMENTAL CONTROLS SHALL COMPLY | | | WITH THE FAIR HOUSING ACT REGULATIONS, | | | CHAPTER 5 FOR ACCESSIBLE LOCATION AND | | | HEIGHT REQUIRMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2002-06-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-03 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-03 |
Time |
18:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2002-05-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-05-01 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-05-01 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2002-05-01 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA AMEND-98 DESIGN | | | MANUAL | | | | | | 1) SHT A-16 SANITARY RISER DIAGRAM FOR | | | UNITS A & C, BATH #3 FROM UPPER UNIT | | | SHALL NOT DRAIN PAST LAUNDRY SINK ON | | | WASTE STACK. BATH #3 SHALL BE TAKEN OFF | | | BELOW LAUNDRY SINK. (FROM PREVIOUS REV- | | | IEW) | | | 2) SHT A-16 SANT RISER DIAG., M/BATH | | | FROM UPPER UNIT SHALL NOT DRAIN INTO | | | BRANCH LINE FOR FIRST FLOOR M/BATH. UP- | | | PER M/BATH SHALL DRAIN INTO BLDG DOWN- | | | STREAM OF M/BATH ON 1ST FLOOR. | | | 3) SHT A-16 SANT RISER DIAG., 4 FIXTURE | | | UNITS MAXIMUM FOR 2" WET VENT IN MASTER | | | BATH SANITARY. 3" PIPE REQUIRED TO STACK | | | (ADDRESSED FOR 2ND FLOOR BUT NOT 1ST) | | | 4) SHT A-16 SANT RISER DIAG., SAME AS | | | NOTE #1, BUT FOR RISER B & D. | | | 5) SHT A-16 SANT RISER DIAG., SAME AS | | | NOTE #2, BUT FOR RISER B & D. | | | 6) SHT A-16 SANT RISER DIAG., SAME AS | | | NOTE #3, BUT FOR RISER B & D> | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2002-03-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-03-14 |
Time |
10:27 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2002-03-14 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2002-03-14 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA AMEND-98 DESIGN | | | MANUAL. | | | | | | 1) FROM PERVIOUS REVIEW - PLEASE SUBMIT | | | MEASUREMENTS FOR WATER CLOSET OPENINGS | | | IN MASTER BATH ALL UNITS. SHTS A-3/A-4 | | | 2) SHT A-16 SANITARY RISER DIAGRAM FOR | | | UNITS A & C. BATH #3 FROM UPPER UNIT CAN | | | NOT DRAIN PAST LAUNDRY SINK ON WASTE | | | STACK. BATH #3 SHALL BE TAKEN OFF BELOW | | | LAUNDRY SINK. | | | 3) SHT A-16 SANT RISER DIAG, M/BATH FROM | | | UPPER UNIT DRAINS INTO 2" SHOWER DRAIN. | | | 4) SHT A-16 SANT RISER DIAG, 4 FIXTURE | | | UNITS MAXIMUM FOR 2" WET VENT IN MASTER | | | BATH SANITARY. 3" PIPE REQUIRED TO STACK | | | SEE NOTE #7 FROM PREVIOUS REVIEW. | | | 5) SHT A-16 SANT RISER DIAG. FOR UNITS | | | B & D, NO LAUNDRY SINK SHOWN FOR UPPER | | | UNIT. | | | 6) SHT A-16 SANT RISER DIAG, BATH #2 | | | DOES NOT REFLECT FLOOR PLAN. FLOOR PLAN | | | SHOWS BATH #2 TAKEN OFF BLDG DRAIN BE- | | | TWEEN WASHER-LAUNDRY SINK & KITCHEN, BUT | | | RISER DIAGRAM SHOWS BATH #2 TAKEN OFF | | | BEFORE WASHER-LAUNDRY SINK. PLSE CLAIRFY | | | 7) SHT A-16 SANT RISER DIAG, SAME AS | | | NOTE #2 EXCEPT FOR RISER B & D. | | | 8) SHT A-16 SANT RISER DIAG, SAME AS | | | NOTE #3 EXCEPT FOR RISER B & D. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2002-02-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-02-04 |
Time |
18:25 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2002-02-04 |
Time |
18:25 |
Sent To |
|
|
| Notes |
| 2002-02-04 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA-AMENDED-98 | | | DESIGN MANUAL | | | | | | 1) ALL UNIT TYPES SHALL COMPLY WITH | | | FAIR HOUSING ACT AMENDED 1998 DESIGN | | | MANUAL REQUIREMENTS 1 THRU 7. INDICATE | | | ON PLANS EITHER OPTION "A" OR "B" FOR | | | BATHROOMS. | | | 2) SHOW CLEAR FLOOR SPACE FOR ALL FIX- | | | TURES IN ALL UNITS PER FHA DESIGN MANUAL | | | 3) ALL WATER CLOSETS SHALL HAVE A MINI- | | | MUM OPENING OF 2'9". SOME SHOW 2'8" AND | | | SOME HAVE NO MEASURMENTS ON THEM. PLEASE | | | SHOW DETAILS ON PLANS FOR PROPER W/C | | | SPACE. | | | 4) PLEASE SEE FHA DESIGN MANUAL FOR LAV | | | TO BE CENTERED ON PARALLEL APPROACH OR | | | IF FRONTAL APPROACH SHOW REMOVABLE BASE | | | CABINET. PLEASE PROVIDE DETAILS ON PLAN. | | | 5) SHT A-16 "A" PLUMBING RISER DIAGRAM, | | | RISER DIAGRAM DOES NOT REFLECT FLOOR | | | PLAN. LAUNDRY SINK NOT SHOWN, 1 BATHROOM | | | MISSING, KITCHEN TO BE ON SAME SIDE OF | | | UNIT AS W/M, WHY ISLAND VENT IN KITCHEN | | | AND WHAT IS OTHER VENT BEFORE ISLAND | | | VENT FOR?, 3" TO STACK IN MASTER BATH | | | (ONLY 4 F.U. ON 2" WET VENT). | | | 6) SHT A-16 "B" PLUMBING RISER DIAGRAM. | | | RISER DIAGRAM DOES NOT REFLECT FLOOR | | | PLAN. LAUNDRY SINK NOT SHOWN, KITCHEN TO | | | BE ON SAME SIDE OF UNIT AS W/M STK, WHY | | | ISLAND VENT FOR KIT. AND WHAT IS VENT | | | BEFORE ISLAND VENT FOR?, BATH #2 TO BE | | | ON OTHER SIDE OF RISER DIAGRAM, 3" TO | | | STACK IN M/BATH (ONLY 4 F.U. ON 2" WET | | | VENT) | | | 7) SHT A-16 "C" PLUMBING RISER DIAGRAM. | | | RISER DIAGRAM DOWS NOT REFLECT FLOOR | | | PLAN. LAUNDRY SINK NOT SHOWN, KITCHEN | | | SHALL BE ON SAME SIDE AS W/M, WHY ISLAND | | | VENT FOR KIT. SINK AND WHAT IS VENT BE- | | | FORE ISLAND SINK FOR?, 3" REQUIRED TO | | | STACK FOR M/BATH (ONLY 4 F.U. ON 2" WET | | | VENT. | | | 8) SHT A-16 "D" PLUMBING RISER DIAGRAM. | | | RISER DIAGRAM DOES NOT REFLECT FLOOR | | | PLAN. LANUDRY SINK NOT SHOWN, W/M AND | | | BATH #2 TO BE ON LEFT SIDE OF RISER DIA. | | | WITH M/BATH, KITCHEN SHALL BE ON RIGHT | | | SIDE OF DIAG., WHY ISLAND VENT FOR KIT. | | | SINK AND WHAT IS VENT BEFORE ISLAND VENT | | | FOR?. | | | 9) IF UNITS ARE NOT INDIVIDUALLY METERED | | | A RPZ BACKFLOW SHALL BE REQUIRED. | | | 10) PLEASE SUBMIT A FLAT DRAWING OF THE | | | BLDG DRAIN AND COMPLETE RISER FOR SAME | | | WITH PIPE SIZING. THIS WILL NOT BE REQ- | | | UIRED IF EACH UNIT IS PIPED OUT OF BLDG | | | INDIVIDUALLY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2002-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-08-01 |
Time |
09:14 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-08-01 00:00:00 | STORM PANEL SUBMITTAL DENIED | | | | | | 1) THE MEANS OF EGRESS FROM THE UNITS | | | MUST BE MAINTAINED. THE STORM PANEL | | | INSTALLATION SCHEDULE INDICATES THAT | | | THE FRONT DOOR AND SIDELITE ARE BEING | | | SHUTTERED. THE ONLY EXIT FROM THE | | | STRUCTURE WOULD BE THROUGH THE GARAGE | | | AND OUT THROUGH THE OVERHEAD DOOR. THE | | | BUILDING OFFICIAL WILL NOT ALLOW THIS. | | | THEIR ARE SEVERAL OPTIONS. THE FRONT | | | DOOR CAN BE IMPACT RATED METAL OR WOOD | | | AND THE SIDELITE CAN BE SHUTTERED. THE | | | FRONT DOOR ASSEMBLY CAN BE IMPACT | | | RESISTANT GLAZING. THE PANELS CAN BE | | | MOUNTED TO A WOOD DOOR WITH BUSHINGS SO | | | THAT THE GLAZING IS PROTECTED. THERE MAY | | | BE OTHER ACCEPTABLE OPTIONS. APPROPRIATE | | | PRODUCT APPROVALS WILL BE REQUIRED FOR | | | THE SELECTED OPTION. PLEASE INDICATE | | | HOW COMPLIANCE WILL BE MET. | | | | | | 2) PLEASE SUBMIT YOUR STORM PANEL | | | INSTALLATION PLAN FOR THE BUILDING | | | OFFICIALS REVIEW. THE FOLLOWING ITEMS | | | MUST BE ADDRESSED. | | | A) WHO WILL INSTALL (BUILDING STAFF) | | | B) TIME TO INSTALL | | | C) STORED ON SITE, INDICATE ON PLANS | | | (IF STORED STANDING, AN ENGINEER IS TO | | | DESIGN THE ENCLOSURE) | | | D) THE BUILDING OFFICIAL MUST APPROVE | | | THE WRITTEN PLAN | | | E) ALLOWED ONLY ON GROUND FLOOR | | | | | | INDICATE ON THE PLAN THAT YOU ARE | | | INSTALLING IMPACT RESISTANT GLAZING ON | | | THE SECOND FLOOR. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2002-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-07-31 |
Time |
15:14 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-07-31 00:00:00 | DENIED | | | SHOP DRAWINGS FOR SECOND FLOOR COVERED | | | PORCH GUARD RAILS | | | | | | 1) SECOND SHEET OF ENGINEERED DRAWINGS | | | NOT SIGNED AND SEALED BY THE ENGINEER. | | | | | | 2) THE PICKETS ON SHEET 2 ARE NOT THE | | | SAME AS SHEET 1. HOW WILL PICKETS SHOWN | | | ON SHEET 1 BE ATTACHED TO RAILS? | | | | | | 3) SPECIFY THE TYPE OF 1/4"X 3" ANCHORS | | | THAT WILL BE USED. TAPCONS? | | | | | | 4) INDICATE HOW THE TOP RAIL OF THE | | | GUARDRAIL WILL ATTACH TO WALL OF THE | | | STRUCTURE AND TO THE 402 COLUMN. SPECIFY | | | NUMBER AND TYPE OF FASTENERS. | | | | | | 5) IN ADDITION TO WINDLOADS, GUARDRAILS | | | MUST BE CAPABLE OF WITHSTANDING LOADS | | | APPLIED TO THE TOP OF THE GUARDRAIL AND | | | A CONCENTRATED HORIZONTAL LOAD AT ANY | | | POINT IN THE GUARDRAIL SYSTEM INCLUDING | | | INTERMEDIATE RAILS. SEE 2001 FBC SECT. | | | 1608.2.2.1 AND 1608.2.2.3 INDICATE THE | | | LOADS THE GUARDRAIL IS CAPABLE OF | | | WITHSTANDING ON THE DRAWINGS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2002-06-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2002-06-12 |
Time |
10:07 |
Rev Time |
1.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-12 00:00:00 | DENIED | | | | | | ADDITIONAL INFORMATION IS REQUIRED ON | | | THE SHOP DRAWINGS FOR THE SECOND FLOOR | | | GUARDRAILS. | | | | | | 1) INDICATE THE HEIGHT OF THE GUARDRAIL | | | ON THE DRAWINGS. THE MINIMUM REQUIRED | | | HEIGHT IS 42". SEE FBC SEC.1015.2. | | | | | | 2) INDICATE THE ATTACHMENT AND FASTENERS | | | THAT WILL BE USED. FBC SEC. 1015.4 | | | | | | 3) INDICATE ON THE DRAWINGS THE LOADS | | | THAT THE GUARDRAIL SYSTEM IS CAPABLE OF | | | RESISTING. SEE FBC SEC 1608.2.2. | | | | | | 4) IN ADDITION TO THE ORNAMENTAL PATTERN | | | THAT RESISTS THE PASSAGE OF A 4-INCH | | | DIAMETER SPHERE A BOTTOM RAIL OR CURB IS | | | REQUIRED THAT WILL REJECT THE PASSAGE OF | | | A 2-INCH DIAMETER SPHERE. PLEASE | | | INDICATE THIS ON THE PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2002-02-04 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2002-02-04 |
Time |
14:04 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|