Plan Review Details - Permit 01121474
Plan Review Stops For Permit 01121474
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2002-06-04 Cont ID  
Sent By btrobaug Date 2002-12-12 Time 13:44 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-05-30 00:00:00BUILDING PROVISO
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT SHOP DRAWINGS FOR GUARDRAILS
 AT SECOND FLOOR COVERED PORCHES FOR
 APPROVAL PRIOR TO INSTALLATION.
  
 4) PROVIDE INSTALLATION SCHEDULE FOR
 THE STORM PANELS THAT WILL BE USED ON
 THE FIRST FLOOR.
  
 5)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL MULLIONS THAT CAN BE
 INSTALLED AS PART OF AN IMPACT
 RESISTANT UNIT.
 - IMPACT RESISTANT SLIDING GLASS DOORS
  
 6) SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND OF THE DESIGN
 PROFESSIONAL OF RECORD. PLEASE SUBMIT
 ORIGINAL SIGNED AND SEALED DOCUMENTS FOR
 THE IMPACT RESISTANT SLIDING GLASS DOORS
 OR SBCCI/METRO-DADE PRODUCT APPROVALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2002-04-15 Cont ID  
Sent By rmcdouga Date 2002-04-15 Time 14:25 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-04-15 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT SHOP DRAWINGS FOR GUARDRAIL AT
 2ND FLOOR COVERED PORCH FOR APPROVAL
 PRIOR TO INSTALLATION.
  
 4)THE REAR ELEVATION SHOWS THE 2ND FLOOR
 GUARDRAIL WITH A 4" SPACE BETWEEN THE
 BOTTOM RAIL AND THE FLOOR. THE CODE
 REQUIRES THAT THE BOTTOM RAIL REJECT THE
 PASSAGE OF A 2" SPHERE. PLEASE CORRECT.
  
 5) SECTION B-B ON SHEET A7 SHOWS A 9.5"
 TREAD EXCLUSIVE OF THE NOSING WITH A
 7.37" RISER AND THE STAIR DETAIL (1/A7)
 NOTES 10"TREAD EXCLUSIVE OF NOSING WITH
 A 7.22" RISER. PLEASE CORRECT.
  
 6) THE FRONT ELEVATION ON A5 NOTES A
 CEMENTITOUS FINISH OVER CONCRETE BLOCK
 CONSTRUCTION AT THE EXTERIOR WALL OF THE
 2ND FLOOR BEDROOM #3, WHICH IS WOOD
 FRAME. PLEASE CORRECT AND INDICATE THE
 EXTERIOR FINISH THAT WILL BE APPLIED TO
 THIS WALL. (WIRE LATH AND STUCCO?)
  
 7) INDICATE FIREBLOCKING WHERE THE WOOD
 EXTERIOR WALL AND CEILING INTERSECT AT
 THE GABLE END OF 2ND FLOOR BEDROOM #3 ON
 SECTION A-A ON SHEET A7.
 INDICATE THAT THE GABLE ENDWALL WILL
 BE BALLOON FRAMED TO THE VAULTED CEILING
 DIAPHRAM.
  
 8) SHEET A1 IS MISSING THE FOOTING
 DESIGNATIONS. THE COLUMN AND FOOTING
 MARKS THAT TIE TO THE SCHEDULES ARE ALSO
 MISSING. PLEASE CORRECT.
  
 9) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
 IMPACT GLAZING OR PERMANENTLY AFFIXED
 PROTECTIVE DEVICES ARE REQUIRED ABOVE
 THE FIRST LEVEL. PERMANENTLY AFFIXED
 PROTECTIVE DEVICES REQUIRE THE WRITTEN
 APPROVAL OF THE BUILDING OFFICIAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-03-22 Cont ID  
Sent By rmcdouga Date 2002-03-22 Time 17:00 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-03-22 00:00:00*************BUILDING UNSAT*************
  
 1) SAME COMMENTS AS 01121475.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2002-02-08 Cont ID  
Sent By rmcdouga Date 2002-02-08 Time 14:16 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-02-08 00:00:00*************BUILDING UNSAT*************
  
 SAME COMMENTS AS PERMIT # 01121475.
  
 TRUSSES DENIED
 SAME COMMENTS AS PERMIT # 01121475.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-12-20 Cont ID  
Sent By btrobaug Date 2002-12-20 Time 10:35 Rev Time 0.50
Received By btrobaug Date 2002-12-20 Time 07:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-03-15 Cont ID  
Sent By btrobaug Date 2002-03-15 Time 17:00 Rev Time 0.00
Received By btrobaug Date 2002-03-15 Time 16:37 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2002-02-05 Cont ID  
Sent By btrobaug Date 2002-02-05 Time 10:18 Rev Time 0.00
Received By btrobaug Date 2002-02-05 Time 09:56 Sent To  
Notes
2002-02-05 00:00:00*******************UNSAT!***************
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND RESUBMIT.
  
 1) A.I.C. RATING AT FIRST MEANS OF
 DISCONNECT,ALL UNITS.
  
 2) "A" & "B" UNITS CONFORM TO 230-3.
  
 3) BATH ROOMS TO COMPLY WITH
 210-52D.INCLUDE SAME IN PANEL SCHEDULES
 AND LOAD CALCULATIONS.
  
 4) GROUND LEVEL UNITS COMPLY WITH
 210-52E.
  
 5)CONDENSING UNITS GFCI,210-63 NEC &
 309.2 MECH.
  
 6)UNIT "D" BED ROOMS 2&3 AND UNIT "C"
 BED ROOM #3 TO COMPLY WITH NFPA-72
 2-2.1.1.1.
  
 7) ALL WIRING TO CONFORM TO THE FAIR
 HOUSING ACT,CHAPTER#524 CFR 100-205.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 (561) 659-8096
 EXT.8392

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2002-02-08 Cont ID  
Sent By rmcdouga Date 2002-02-08 Time 14:21 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-03-20 Cont ID  
Sent By mcarsill Date 2002-03-20 Time 11:24 Rev Time 0.00
Received By mcarsill Date 2002-03-20 Time 11:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2002-02-06 Cont ID  
Sent By btrobaug Date 2002-03-15 Time 17:00 Rev Time 0.00
Received By mcarsill Date 2002-02-06 Time 08:20 Sent To  
Notes
2002-02-06 00:00:001) BUILDING ADDRESSES REQUIRED.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 3) PORTABLE FIRE EXTINGUISHERS REQUIRED.
 4) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED.
 5) PLEASE INDENTIFY ALL EGRESS WINDOWS
 ON THE PLANS AND MAXIMUM SILL HEIGHTS.
 6) PLEASE INDENTIFY INTERIOR FINISH
 CLASSIFICATIONS FOR WALLS AND CEILINGS.
 7) THE C LABELED FIRE DOORS ARE REQUIRED
 TO BE EQUIPPED WITH SELF-CLOSING
 DEVICES.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-12-12 Cont ID  
Sent By btrobaug Date 2002-12-12 Time 13:44 Rev Time 0.00
Received By btrobaug Date 2002-12-12 Time 13:44 Sent To B
Notes
2002-12-12 00:00:00ROB M./WRT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-04-18 Cont ID  
Sent By pkrauss Date 2002-04-18 Time 09:38 Rev Time 0.50
Received By pkrauss Date 2002-04-18 Time 09:38 Sent To  
Notes
2002-04-18 00:00:001997 SMC - BUILDING #4
 MECHANICAL PERMIT 02041143
  
 MANUFACTURER SUBMITTAL DATA FOR THE
 DRYERS SUBMITTED.
  
 SEE ALSO A-3 FOR ADDITIONAL MECHANICAL
 NOTES.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2002-02-05 Cont ID  
Sent By pkrauss Date 2002-02-05 Time 08:52 Rev Time 1.20
Received By pkrauss Date 2002-02-05 Time 08:52 Sent To  
Notes
2002-02-05 00:00:00 
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE THE FOLLOWING
 INFORMATION WITH MECHANICAL PLANS AND
 PERMIT.
  
 1.DUCT LAYOUT - SIZE, MATERIAL, R -
 VALUE, AND CFM DISTRIBUTION.
  
 2.PROVIDE GRILLE SIZE.
  
 3.HVAC EQUIPMENT SCHEDULE - MAKE,
 MODEL, BTU, KW HEAT STRIP AND SEER
 OF THE CONDENSER.
  
 4.INDICATE SIZE OF THE REFRIGERATION
 AND CONDENSATE LINES.PROVIDE
 PIPING LAYOUT FROM AHU TO CONDENSER.
  
 5.CONDENSATE FROM UNITS LARGER THAN
 3 TON SHALL TERMINATE INTO AN
 APPROVED DRYWELL OR STORM DRAIN.
  
 6.PROVIDE DETAIL OF DRYER EXHAUST.
 INDICATE TERMINATION (ROOF OR WALL),
 ARE DUCTS IN A FIRE RATED CHASE?
 PLEASE NOTE AS PER 1997 SMC 509.3,
 MINIMUM SIZE 4" WITH A MAXIMUM
 LENGTH OF 25' (5' REDUCTION FOR EACH
 90 DEGREE BEND & 2 1/2 REDUCTION FOR
 EACH 45 DEGREE BEND).WALL OR ROOF
 CAP SHALL BE NON SCREENED WITH A
 BACKDRAFT DAMPER.
  
 7.BATHROOM EXHAUST - INDICATE DUCT
 SIZE, MATERIAL, AND TERMINATION.
  
 ALL ENVIRONMENTAL CONTROLS SHALL COMPLY
 WITH THE FAIR HOUSING ACT REGULATIONS,
 CHAPTER 5 FOR ACCESSIBLE LOCATION AND
 HEIGHT REQUIRMENTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-06-03 Cont ID  
Sent By kstevens Date 2002-06-03 Time 18:01 Rev Time 0.00
Received By kstevens Date 2002-06-03 Time 18:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-05-01 Cont ID  
Sent By kstevens Date 2002-05-01 Time 14:07 Rev Time 0.00
Received By kstevens Date 2002-05-01 Time 14:06 Sent To  
Notes
2002-05-01 00:00:00DENIED
 REFERENCE: SPC-94 - FHA AMEND-98 DESIGN
 MANUAL
  
 1) SHT A-16 SANITARY RISER DIAGRAM FOR
 UNITS A & C, BATH #3 FROM UPPER UNIT
 SHALL NOT DRAIN PAST LAUNDRY SINK ON
 WASTE STACK. BATH #3 SHALL BE TAKEN OFF
 BELOW LAUNDRY SINK. (FROM PREVIOUS REV-
 IEW)
 2) SHT A-16 SANT RISER DIAG., M/BATH
 FROM UPPER UNIT SHALL NOT DRAIN INTO
 BRANCH LINE FOR FIRST FLOOR M/BATH. UP-
 PER M/BATH SHALL DRAIN INTO BLDG DOWN-
 STREAM OF M/BATH ON 1ST FLOOR.
 3) SHT A-16 SANT RISER DIAG., 4 FIXTURE
 UNITS MAXIMUM FOR 2" WET VENT IN MASTER
 BATH SANITARY. 3" PIPE REQUIRED TO STACK
 (ADDRESSED FOR 2ND FLOOR BUT NOT 1ST)
 4) SHT A-16 SANT RISER DIAG., SAME AS
 NOTE #1, BUT FOR RISER B & D.
 5) SHT A-16 SANT RISER DIAG., SAME AS
 NOTE #2, BUT FOR RISER B & D.
 6) SHT A-16 SANT RISER DIAG., SAME AS
 NOTE #3, BUT FOR RISER B & D>
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2002-03-14 Cont ID  
Sent By kstevens Date 2002-03-14 Time 10:27 Rev Time 1.00
Received By kstevens Date 2002-03-14 Time 10:27 Sent To  
Notes
2002-03-14 00:00:00DENIED
 REFERENCE: SPC-94 - FHA AMEND-98 DESIGN
 MANUAL.
  
 1) FROM PERVIOUS REVIEW - PLEASE SUBMIT
 MEASUREMENTS FOR WATER CLOSET OPENINGS
 IN MASTER BATH ALL UNITS. SHTS A-3/A-4
 2) SHT A-16 SANITARY RISER DIAGRAM FOR
 UNITS A & C. BATH #3 FROM UPPER UNIT CAN
 NOT DRAIN PAST LAUNDRY SINK ON WASTE
 STACK. BATH #3 SHALL BE TAKEN OFF BELOW
 LAUNDRY SINK.
 3) SHT A-16 SANT RISER DIAG, M/BATH FROM
 UPPER UNIT DRAINS INTO 2" SHOWER DRAIN.
 4) SHT A-16 SANT RISER DIAG, 4 FIXTURE
 UNITS MAXIMUM FOR 2" WET VENT IN MASTER
 BATH SANITARY. 3" PIPE REQUIRED TO STACK
 SEE NOTE #7 FROM PREVIOUS REVIEW.
 5) SHT A-16 SANT RISER DIAG. FOR UNITS
 B & D, NO LAUNDRY SINK SHOWN FOR UPPER
 UNIT.
 6) SHT A-16 SANT RISER DIAG, BATH #2
 DOES NOT REFLECT FLOOR PLAN. FLOOR PLAN
 SHOWS BATH #2 TAKEN OFF BLDG DRAIN BE-
 TWEEN WASHER-LAUNDRY SINK & KITCHEN, BUT
 RISER DIAGRAM SHOWS BATH #2 TAKEN OFF
 BEFORE WASHER-LAUNDRY SINK. PLSE CLAIRFY
 7) SHT A-16 SANT RISER DIAG, SAME AS
 NOTE #2 EXCEPT FOR RISER B & D.
 8) SHT A-16 SANT RISER DIAG, SAME AS
 NOTE #3 EXCEPT FOR RISER B & D.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2002-02-04 Cont ID  
Sent By kstevens Date 2002-02-04 Time 18:25 Rev Time 2.00
Received By kstevens Date 2002-02-04 Time 18:25 Sent To  
Notes
2002-02-04 00:00:00DENIED
 REFERENCE: SPC-94 - FHA-AMENDED-98
 DESIGN MANUAL
  
 1) ALL UNIT TYPES SHALL COMPLY WITH
 FAIR HOUSING ACT AMENDED 1998 DESIGN
 MANUAL REQUIREMENTS 1 THRU 7. INDICATE
 ON PLANS EITHER OPTION "A" OR "B" FOR
 BATHROOMS.
 2) SHOW CLEAR FLOOR SPACE FOR ALL FIX-
 TURES IN ALL UNITS PER FHA DESIGN MANUAL
 3) ALL WATER CLOSETS SHALL HAVE A MINI-
 MUM OPENING OF 2'9". SOME SHOW 2'8" AND
 SOME HAVE NO MEASURMENTS ON THEM. PLEASE
 SHOW DETAILS ON PLANS FOR PROPER W/C
 SPACE.
 4) PLEASE SEE FHA DESIGN MANUAL FOR LAV
 TO BE CENTERED ON PARALLEL APPROACH OR
 IF FRONTAL APPROACH SHOW REMOVABLE BASE
 CABINET. PLEASE PROVIDE DETAILS ON PLAN.
 5) SHT A-16 "A" PLUMBING RISER DIAGRAM,
 RISER DIAGRAM DOES NOT REFLECT FLOOR
 PLAN. LAUNDRY SINK NOT SHOWN, 1 BATHROOM
 MISSING, KITCHEN TO BE ON SAME SIDE OF
 UNIT AS W/M, WHY ISLAND VENT IN KITCHEN
 AND WHAT IS OTHER VENT BEFORE ISLAND
 VENT FOR?, 3" TO STACK IN MASTER BATH
 (ONLY 4 F.U. ON 2" WET VENT).
 6) SHT A-16 "B" PLUMBING RISER DIAGRAM.
 RISER DIAGRAM DOES NOT REFLECT FLOOR
 PLAN. LAUNDRY SINK NOT SHOWN, KITCHEN TO
 BE ON SAME SIDE OF UNIT AS W/M STK, WHY
 ISLAND VENT FOR KIT. AND WHAT IS VENT
 BEFORE ISLAND VENT FOR?, BATH #2 TO BE
 ON OTHER SIDE OF RISER DIAGRAM, 3" TO
 STACK IN M/BATH (ONLY 4 F.U. ON 2" WET
 VENT)
 7) SHT A-16 "C" PLUMBING RISER DIAGRAM.
 RISER DIAGRAM DOWS NOT REFLECT FLOOR
 PLAN. LAUNDRY SINK NOT SHOWN, KITCHEN
 SHALL BE ON SAME SIDE AS W/M, WHY ISLAND
 VENT FOR KIT. SINK AND WHAT IS VENT BE-
 FORE ISLAND SINK FOR?, 3" REQUIRED TO
 STACK FOR M/BATH (ONLY 4 F.U. ON 2" WET
 VENT.
 8) SHT A-16 "D" PLUMBING RISER DIAGRAM.
 RISER DIAGRAM DOES NOT REFLECT FLOOR
 PLAN. LANUDRY SINK NOT SHOWN, W/M AND
 BATH #2 TO BE ON LEFT SIDE OF RISER DIA.
 WITH M/BATH, KITCHEN SHALL BE ON RIGHT
 SIDE OF DIAG., WHY ISLAND VENT FOR KIT.
 SINK AND WHAT IS VENT BEFORE ISLAND VENT
 FOR?.
 9) IF UNITS ARE NOT INDIVIDUALLY METERED
 A RPZ BACKFLOW SHALL BE REQUIRED.
 10) PLEASE SUBMIT A FLAT DRAWING OF THE
 BLDG DRAIN AND COMPLETE RISER FOR SAME
 WITH PIPE SIZING. THIS WILL NOT BE REQ-
 UIRED IF EACH UNIT IS PIPED OUT OF BLDG
 INDIVIDUALLY.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2002-08-01 Cont ID  
Sent By rmcdouga Date 2002-08-01 Time 09:14 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-08-01 00:00:00STORM PANEL SUBMITTAL DENIED
  
 1) THE MEANS OF EGRESS FROM THE UNITS
 MUST BE MAINTAINED. THE STORM PANEL
 INSTALLATION SCHEDULE INDICATES THAT
 THE FRONT DOOR AND SIDELITE ARE BEING
 SHUTTERED. THE ONLY EXIT FROM THE
 STRUCTURE WOULD BE THROUGH THE GARAGE
 AND OUT THROUGH THE OVERHEAD DOOR. THE
 BUILDING OFFICIAL WILL NOT ALLOW THIS.
 THEIR ARE SEVERAL OPTIONS. THE FRONT
 DOOR CAN BE IMPACT RATED METAL OR WOOD
 AND THE SIDELITE CAN BE SHUTTERED. THE
 FRONT DOOR ASSEMBLY CAN BE IMPACT
 RESISTANT GLAZING. THE PANELS CAN BE
 MOUNTED TO A WOOD DOOR WITH BUSHINGS SO
 THAT THE GLAZING IS PROTECTED. THERE MAY
 BE OTHER ACCEPTABLE OPTIONS. APPROPRIATE
 PRODUCT APPROVALS WILL BE REQUIRED FOR
 THE SELECTED OPTION. PLEASE INDICATE
 HOW COMPLIANCE WILL BE MET.
  
 2) PLEASE SUBMIT YOUR STORM PANEL
 INSTALLATION PLAN FOR THE BUILDING
 OFFICIALS REVIEW. THE FOLLOWING ITEMS
 MUST BE ADDRESSED.
 A) WHO WILL INSTALL (BUILDING STAFF)
 B) TIME TO INSTALL
 C) STORED ON SITE, INDICATE ON PLANS
 (IF STORED STANDING, AN ENGINEER IS TO
 DESIGN THE ENCLOSURE)
 D) THE BUILDING OFFICIAL MUST APPROVE
 THE WRITTEN PLAN
 E) ALLOWED ONLY ON GROUND FLOOR
  
 INDICATE ON THE PLAN THAT YOU ARE
 INSTALLING IMPACT RESISTANT GLAZING ON
 THE SECOND FLOOR.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2002-07-31 Cont ID  
Sent By rmcdouga Date 2002-07-31 Time 15:14 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-07-31 00:00:00DENIED
 SHOP DRAWINGS FOR SECOND FLOOR COVERED
 PORCH GUARD RAILS
  
 1) SECOND SHEET OF ENGINEERED DRAWINGS
 NOT SIGNED AND SEALED BY THE ENGINEER.
  
 2) THE PICKETS ON SHEET 2 ARE NOT THE
 SAME AS SHEET 1. HOW WILL PICKETS SHOWN
 ON SHEET 1 BE ATTACHED TO RAILS?
  
 3) SPECIFY THE TYPE OF 1/4"X 3" ANCHORS
 THAT WILL BE USED. TAPCONS?
  
 4) INDICATE HOW THE TOP RAIL OF THE
 GUARDRAIL WILL ATTACH TO WALL OF THE
 STRUCTURE AND TO THE 402 COLUMN. SPECIFY
 NUMBER AND TYPE OF FASTENERS.
  
 5) IN ADDITION TO WINDLOADS, GUARDRAILS
 MUST BE CAPABLE OF WITHSTANDING LOADS
 APPLIED TO THE TOP OF THE GUARDRAIL AND
 A CONCENTRATED HORIZONTAL LOAD AT ANY
 POINT IN THE GUARDRAIL SYSTEM INCLUDING
 INTERMEDIATE RAILS. SEE 2001 FBC SECT.
 1608.2.2.1 AND 1608.2.2.3 INDICATE THE
 LOADS THE GUARDRAIL IS CAPABLE OF
 WITHSTANDING ON THE DRAWINGS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2002-06-12 Cont ID  
Sent By rmcdouga Date 2002-06-12 Time 10:07 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2002-06-12 00:00:00DENIED
  
 ADDITIONAL INFORMATION IS REQUIRED ON
 THE SHOP DRAWINGS FOR THE SECOND FLOOR
 GUARDRAILS.
  
 1) INDICATE THE HEIGHT OF THE GUARDRAIL
 ON THE DRAWINGS. THE MINIMUM REQUIRED
 HEIGHT IS 42". SEE FBC SEC.1015.2.
  
 2) INDICATE THE ATTACHMENT AND FASTENERS
 THAT WILL BE USED. FBC SEC. 1015.4
  
 3) INDICATE ON THE DRAWINGS THE LOADS
 THAT THE GUARDRAIL SYSTEM IS CAPABLE OF
 RESISTING. SEE FBC SEC 1608.2.2.
  
 4) IN ADDITION TO THE ORNAMENTAL PATTERN
 THAT RESISTS THE PASSAGE OF A 4-INCH
 DIAMETER SPHERE A BOTTOM RAIL OR CURB IS
 REQUIRED THAT WILL REJECT THE PASSAGE OF
 A 2-INCH DIAMETER SPHERE. PLEASE
 INDICATE THIS ON THE PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2002-02-04 Cont ID  
Sent By sgraham Date 2002-02-04 Time 14:04 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***