| Plan Review Stops For Permit 01120633 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2002-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-06-29 |
Time |
08:42 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 01120633 | | | ADD: 1501 DIVISION AV | | | CONT: WINGATE BUILDERS | | | TEL: (561)863-9560 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) SEPERATE PERMIT REQUIRED, NOT PART OF | | | BUILDING PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-12-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-12-28 |
Time |
14:49 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-28 00:00:00 | BUILDING PROVISO: | | | PERMIT # 01120633 | | | 1501 DIVISION AV. | | | CONT: WINGATE CONT. | | | TEL: (561) 718-2000 | | | | | | 1)- THE PLANS FOR THE APOSTOLIC CHILD | | | DEVELOPMENT CENTER DO NOT INDICATE THE | | | TYPE OF MATERIALS THE ACCESSIBLE FRONT | | | ENTRY RAMP WILL BE CONSTRUCTED OF? | | | | | | THE ACCESSIBLE ENTRY SHALL COMPLY WITH | | | ALL THE REQUIREMENTS OF THE 1997 FL ACC | | | CODE 4.8.1 - 4.8.8.TWO SETS OF DETAILS | | | SHALL BE REQUIRED BEFORE THE FIRST | | | INSPECTION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-20 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-20 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2002-06-25 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-06-25 |
Time |
10:25 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-06-25 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2002-06-25 00:00:00 | FAILED : | | | 1. PLEASE REFER TO THE REVIEW COMMENTS | | | DATED 12-24-01, MUST SUBMIT APPLICATIONS | | | FOR CIVIL /SITE PERMITTING FOR BOTH | | | PROPOSED PARKING AREA AND SITE | | | SEPARATELY. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2001-12-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-12-27 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2001-12-27 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2001-12-27 00:00:00 | APPLICANT WILL APPLY FOR SITE/UNDER- | | | GROUND UTILITIES WORKS SEPARATELY. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-12-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-12-24 |
Time |
10:23 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2001-12-24 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2001-12-24 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE STORM WATER | | | CALCULATIONS FOR OUR REVIEW AND APPROVAL | | | 2. PLEASE STATE THAT, WHY THERE ARE TWO | | | DETAILS SHOWN FOR EXFILTRATION TRENCH, | | | SHEET 3 OF 4 AND 4 OF 4. | | | 3. IS THERE ANY NEW CONNECTIONS TO THE | | | CITY'S WATER AND SEWER.IF SO, BACKFLOW | | | PREVENTERS AND CLEAN-OUT MUST BE SHOWN. | | | ALSO PLANS FOR SUCH CONNECTIONS MUST BE | | | SUBMITTED TO PUBLIC UTILITIES FOR THIER | | | REVIEW AND APPROVAL, 659-8040. | | | 4. CONCRETE TURNOUTS MUST BE AT MIN. PER | | | CITY'S STANDARD. SEE ATTACHED. | | | 5. AT MIN. 12" SUBGRADE MUST BE PROVIDED | | | 6. ALL OFF- STREET PARKING STALLS MUST | | | BE PAINTED WITH DOUBLE 4" WHITE AND BLUE | | | FOR H.C. | | | 7. A SEPARATE PERMIT APPLICATION FOR | | | SITE/UNDRGROUND UTILITIES WORKS IS | | | REQUIRED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-12-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-12-27 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-12-27 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-12-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-12-18 |
Time |
16:41 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-12-18 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-01-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-24 |
Time |
07:50 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-01-24 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2003-01-24 00:00:00 | CHANGED BACKFLOW FROM DUAL TO SINGLE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2002-06-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-06-26 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-06-26 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2002-06-26 00:00:00 | REVISION OK - SEWER SHOWN - METER & | | | BACKFLOW/WATER SERVICE - IRRIGATION WILL | | | BE ON WELL - SFWM APPROVAL REQUIRED FOR | | | WELL - SEPARATE PERMIT REQUIRED FOR | | | IRRIGATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-12-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-19 |
Time |
15:15 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-19 00:00:00 | PLUMBING PLAN REVIEW:PROVISO. | | | SANITARY SEWER NOT SHOWN, PROVIDE PLBG. | | | ISOMETRIC FOR CONNECTION OF MODULAR | | | UNITS TO SANITARY SEWER. | | | SHOW LOCATION OF BACK FLOW PREVENTERS | | | FOR DOMESTIC AND IRRIGATION WATER. | | | END OF COMMENTSPAUL SCHMITZ | | | QESTIONS561-659-8096XX 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-12-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-12-13 |
Time |
15:48 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|