Plan Review Details - Permit 01120633
Plan Review Stops For Permit 01120633
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2002-06-29 Cont ID  
Sent By jwitmer Date 2002-06-29 Time 08:42 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-06-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 01120633
 ADD: 1501 DIVISION AV
 CONT: WINGATE BUILDERS
 TEL: (561)863-9560
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) SEPERATE PERMIT REQUIRED, NOT PART OF
 BUILDING PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-12-28 Cont ID  
Sent By jwitmer Date 2001-12-28 Time 14:49 Rev Time 2.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-12-28 00:00:00BUILDING PROVISO:
 PERMIT # 01120633
 1501 DIVISION AV.
 CONT: WINGATE CONT.
 TEL: (561) 718-2000
  
 1)- THE PLANS FOR THE APOSTOLIC CHILD
 DEVELOPMENT CENTER DO NOT INDICATE THE
 TYPE OF MATERIALS THE ACCESSIBLE FRONT
 ENTRY RAMP WILL BE CONSTRUCTED OF?
  
 THE ACCESSIBLE ENTRY SHALL COMPLY WITH
 ALL THE REQUIREMENTS OF THE 1997 FL ACC
 CODE 4.8.1 - 4.8.8.TWO SETS OF DETAILS
 SHALL BE REQUIRED BEFORE THE FIRST
 INSPECTION.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-12-20 Cont ID  
Sent By dpalmer Date 2001-12-20 Time 11:52 Rev Time 0.00
Received By dpalmer Date 2001-12-20 Time 11:52 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2002-06-25 Cont ID  
Sent By mamini Date 2002-06-25 Time 10:25 Rev Time 1.00
Received By mamini Date 2002-06-25 Time 10:25 Sent To  
Notes
2002-06-25 00:00:00FAILED :
 1. PLEASE REFER TO THE REVIEW COMMENTS
 DATED 12-24-01, MUST SUBMIT APPLICATIONS
 FOR CIVIL /SITE PERMITTING FOR BOTH
 PROPOSED PARKING AREA AND SITE
 SEPARATELY.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status N Date 2001-12-27 Cont ID  
Sent By mamini Date 2001-12-27 Time 10:14 Rev Time 0.00
Received By mamini Date 2001-12-27 Time 10:14 Sent To  
Notes
2001-12-27 00:00:00APPLICANT WILL APPLY FOR SITE/UNDER-
 GROUND UTILITIES WORKS SEPARATELY.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2001-12-24 Cont ID  
Sent By mamini Date 2001-12-24 Time 10:23 Rev Time 2.00
Received By mamini Date 2001-12-24 Time 10:23 Sent To  
Notes
2001-12-24 00:00:00FAILED:
 1. PLEASE PROVIDE STORM WATER
 CALCULATIONS FOR OUR REVIEW AND APPROVAL
 2. PLEASE STATE THAT, WHY THERE ARE TWO
 DETAILS SHOWN FOR EXFILTRATION TRENCH,
 SHEET 3 OF 4 AND 4 OF 4.
 3. IS THERE ANY NEW CONNECTIONS TO THE
 CITY'S WATER AND SEWER.IF SO, BACKFLOW
 PREVENTERS AND CLEAN-OUT MUST BE SHOWN.
 ALSO PLANS FOR SUCH CONNECTIONS MUST BE
 SUBMITTED TO PUBLIC UTILITIES FOR THIER
 REVIEW AND APPROVAL, 659-8040.
 4. CONCRETE TURNOUTS MUST BE AT MIN. PER
 CITY'S STANDARD. SEE ATTACHED.
 5. AT MIN. 12" SUBGRADE MUST BE PROVIDED
 6. ALL OFF- STREET PARKING STALLS MUST
 BE PAINTED WITH DOUBLE 4" WHITE AND BLUE
 FOR H.C.
 7. A SEPARATE PERMIT APPLICATION FOR
 SITE/UNDRGROUND UTILITIES WORKS IS
 REQUIRED.
 IF ANY QUESTIONS PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-12-27 Cont ID  
Sent By mcarsill Date 2001-12-27 Time 10:13 Rev Time 0.00
Received By mcarsill Date 2001-12-27 Time 10:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-18 Cont ID  
Sent By pkrauss Date 2001-12-18 Time 16:41 Rev Time 0.40
Received By pkrauss Date 2001-12-18 Time 16:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-01-24 Cont ID  
Sent By kstevens Date 2003-01-24 Time 07:50 Rev Time 1.00
Received By kstevens Date 2003-01-24 Time 07:50 Sent To  
Notes
2003-01-24 00:00:00CHANGED BACKFLOW FROM DUAL TO SINGLE.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-06-26 Cont ID  
Sent By kstevens Date 2002-06-26 Time 11:13 Rev Time 0.00
Received By kstevens Date 2002-06-26 Time 11:13 Sent To  
Notes
2002-06-26 00:00:00REVISION OK - SEWER SHOWN - METER &
 BACKFLOW/WATER SERVICE - IRRIGATION WILL
 BE ON WELL - SFWM APPROVAL REQUIRED FOR
 WELL - SEPARATE PERMIT REQUIRED FOR
 IRRIGATION.

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-12-19 Cont ID  
Sent By pschmitz Date 2001-12-19 Time 15:15 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-12-19 00:00:00PLUMBING PLAN REVIEW:PROVISO.
 SANITARY SEWER NOT SHOWN, PROVIDE PLBG.
 ISOMETRIC FOR CONNECTION OF MODULAR
 UNITS TO SANITARY SEWER.
 SHOW LOCATION OF BACK FLOW PREVENTERS
 FOR DOMESTIC AND IRRIGATION WATER.
 END OF COMMENTSPAUL SCHMITZ
 QESTIONS561-659-8096XX 8233

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-13 Cont ID  
Sent By sgraham Date 2001-12-13 Time 15:48 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***