Plan Review Details - Permit 01120366
Plan Review Stops For Permit 01120366
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2002-01-02 Cont ID  
Sent By dpalmer Date 2002-01-02 Time 06:56 Rev Time 0.00
Received By dpalmer Date 2002-01-02 Time 06:56 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-12-27 Cont ID  
Sent By hmoser Date 2001-12-27 Time 20:07 Rev Time 0.33
Received By hmoser Date 2001-12-27 Time 20:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-12-26 Cont ID  
Sent By jleech Date 2001-12-26 Time 19:29 Rev Time 0.33
Received By jleech Date 2001-12-26 Time 19:29 Sent To  
Notes
2001-12-26 00:00:00PROVISO;
 FOUNDATION PLAN SANITARY PIPING NOT TO
 CODE OR LIKE SANITARY RISER DIAGRAM.
 REVISED FOUNDATION PLAN REQUIRED BEFORE
 FINAL PLUMBING INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2002-01-24 Cont ID  
Sent By jgomez Date 2002-01-24 Time 12:03 Rev Time 0.50
Received By jgomez Date 2002-01-24 Time 12:02 Sent To  
Notes
2002-01-24 00:00:00TRUSS DRAWINGS PROVISO:
 1-ENGINEER OF RECORD TO REVISE TRUSS
 CONNECTOR FOR TRUSSES S6 AND S13 FOR
 CONNECTORS THAT WILL RESIST THE
 UPLIFT LOADS CALCULATED ON THE
 ENGINEERED TRUSSES.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2002-01-15 Cont ID  
Sent By jgomez Date 2002-01-12 Time 14:33 Rev Time 3.00
Received By jgomez Date 2002-01-12 Time 14:33 Sent To  
Notes
2002-01-12 00:00:00APPROVED WITH PROVISO:
 1-FLOD ZONE A8. WILL NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
  
 2-RESUBMIT STORM PANELS PRODUCT APPROVAL
 DRAWINGS SUBMITTED ARE VALID FOR ONE
 PERMIT ONLY. SEE NOTE ON STORM SHUTTER
 DRAWINGS.
 3-PROVIDE UPDATED PRODUCT APPROVAL FOR
 ENTRY DOOR.
 4-REVISE DETAIL AND SPECIFICATIONS FOR
 CEILING INSTALLATION AT ENTRY AND REAR
 PORCHES. SEE ASTM C926 AND ASTM C1063.
 REVISE ORIGINAL DRAWING TO AVOID
 FUTURE DELAYS OR FIELD CONFLICTS.
 5-SUBMIT CURRENT PRODUCT APPROVAL FOR
 GARAGE DOOR. PRODUCT APPROVAL THAT
 WAS SUBMITTED WAS DELETED BY SBCCI.
 6-CLARIFY ROOF SHEATHING FASTENING:
 WALL SECTION ON DRAWING A2 SAYS ONE
 THING AND STRUCTURAL NOTES ON DRAWING
 A4 SAYS ANOTHER. REVISE AS REQUIRED.
 7-PROVIDE PRODUCT APPROVAL FOR ONE HOUR
 FIRE RATED GLASS BLOCK OR DELETE
 OPTION FROM DRAWINGS.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-12-21 Cont ID  
Sent By sgraham Date 2001-12-21 Time 11:06 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***